Literature DB >> 27475313

Preclinical study on an animal model of a new non-adhesive cyanoacrylate (Purefill®) for arterial embolization.

J Izaaryene1, M Saeed Kilani2, P-H Rolland3, J-Y Gaubert4, A Jacquier2, J-M Bartoli2, V Vidal2.   

Abstract

PURPOSE: The goal of this study was to assess the distal dispersion, the adhesion strength to catheter, the vascular toxicity and the ability in excluding embolized vessels using Purefill® (α-hexil-cyanoacrylate) as embolic material, which is a new high purity cyanoacrylate and compare these results with those obtained with N-butyl-2-cyanoacrylate (Histoacryl®) and a mixture of N-butyl-2-cyanoacrylate and methacryloxysulfolane.
MATERIAL AND METHODS: In six pigs, the right rete mirabile (RM) and right renal arteries were embolized with α-hexil-cyanoacrylate, and the left rete mirabile and left renal artery were embolized with N-butyl-2-cyanoacrylate and N-butyl-2-cyanoacrylate+Methacryloxysulfolane for comparison. One minute after glue injection through the microcatheter, displacements of the kidney and the pharyngeal artery were measured on angiographic images, before exercising any traction and during catheter pulling, when the forces were maximal. Displacement was measured in terms of distance (mm) with respect to renal pedicles and in terms of angle (°) with respect to the rete. After acute embolization (4 pigs) or three-month follow-up (2 pigs), the kidneys and the RM were removed and further analysed using computed tomography and histopathological examination.
RESULTS: Similar short and long-term embolic efficacies were observed with the three glues. The mean displacement distances of renal pedicles were 2.6mm for α-hexil-cyanoacrylate, 22.6mm for N-butyl-2-cyanoacrylate and 19.8mm for N-butyl-2-cyanoacrylate+Methacryloxysulfolane (P=0.021). The mean angles of displacement of the ascending pharyngeal arteries were for 12.2° for α-hexil-cyanoacrylate, 23.5° for N-butyl-2-cyanoacrylate and 30° for N-butyl-2-cyanoacrylate+Methacryloxysulfolane (P=0.070). Histopathologically, findings were similar for the three glues, immediately and 90 days after embolization.
CONCLUSION: α-hexil-cyanoacrylate has occlusive efficacy in the short and long term similar to those of N-butyl-2-cyanoacrylate and N-butyl-2-cyanoacrylate+Methacryloxysulfolane. In addition, histopathological changes are similar with the three glues immediately or 90 days after embolization. Conversely, α-hexil-cyanoacrylate results in a reduced angle and distance of displacement compared to the other two glues, assumably reflecting a limited adhesive strength.
Copyright © 2016. Published by Elsevier Masson SAS.

Entities:  

Keywords:  Arterial embolization; Cyanoacrylate; Embolic material; Interventional radiology; Purefill

Mesh:

Substances:

Year:  2016        PMID: 27475313     DOI: 10.1016/j.diii.2016.05.013

Source DB:  PubMed          Journal:  Diagn Interv Imaging        ISSN: 2211-5684            Impact factor:   4.026


  3 in total

1.  Imaging artifacts of Onyx and PHIL on conventional CT, cone-beam CT and MRI in an animal model.

Authors:  Dominik F Vollherbst; Ruth Otto; Thuy Do; Hans U Kauczor; Martin Bendszus; Christof M Sommer; Markus A Möhlenbruch
Journal:  Interv Neuroradiol       Date:  2018-07-04       Impact factor: 1.610

2.  Combination of Alcohol and EVOH as a New Embolic Agent: Midterm Tissue and Inflammatory Effects in a Swine Model.

Authors:  Jean-François Hak; Farouk Tradi; Mickael Bobot; Pauline Brige; Paul Habert; Sophie Chopinet; Aurélie Haffner; Gilles Soulez; Benjamin Guillet; Vincent Vidal
Journal:  Radiol Res Pract       Date:  2020-10-23

Review 3.  Glue, Onyx, Squid or PHIL? Liquid Embolic Agents for the Embolization of Cerebral Arteriovenous Malformations and Dural Arteriovenous Fistulas.

Authors:  Dominik F Vollherbst; René Chapot; Martin Bendszus; Markus A Möhlenbruch
Journal:  Clin Neuroradiol       Date:  2021-07-29       Impact factor: 3.649

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.