BACKGROUND: Embolic protection devices are used during carotid artery stenting procedures to reduce risk of distal embolization. Although this is a standard procedural recommendation, no studies have shown superiority of these devices over unprotected stenting procedures.
OBJECTIVE: To assess the periprocedural outcome and durability of carotid artery stenting without embolic protection devices and poststent angioplasty.
METHODS: We performed a retrospective chart review of 174 carotid angioplasty stent procedures performed at our institution. One hundred sixty-six patients underwent angioplasty and stenting without distal protection devices or poststent angioplasty. Complications related to stenting, including procedural complications, postoperative stroke and/or myocardial infarction, and stent restenosis were analyzed.
RESULTS: One hundred thirty-five stents (78%) were performed in symptomatic patients, whereas 22% of stents were placed for asymptomatic internal carotid artery stenosis. The degree of stenosis was 80% or greater in 75% of patients and 90% or greater in 55% of patients. Following the stenting procedure, the 24-hour and 30-day rate of transient ischemic attack, intracranial hemorrhage, or ischemic stroke was 0. Three (2%) patients had a perioperative, non-ST elevation myocardial infarction. Five patients (2.8%) required treatment for restenosis (>50% stenosis from baseline), 1 of which was symptomatic.
CONCLUSION: Our data show that carotid artery stenting without the use of embolic protection devices and without postangioplasty stenting, in experienced hands, can be performed safely. Furthermore, this technique does not result in a higher degree of in-stent restenosis than series in which poststenting angioplasty is performed.
Copyright © 2016 by the Congress of Neurological Surgeons

Entities:  

Keywords:  Angioplasty; Carotid artery; Embolic protection device; Stenting

Mesh:

Year:  2017        PMID: 27471973     DOI: 10.1227/NEU.0000000000001367

Source DB:  PubMed          Journal:  Neurosurgery        ISSN: 0148-396X            Impact factor:   4.654


  2 in total

1.  Carotid Revascularization with and without the Use of an Embolic Protection Device: A Single-Center Experience from Pakistan.

Authors:  Qasim Bashir; Ammad Anwar Baig
Journal:  Interv Neurol       Date:  2018-06-11

2.  Neurointerventional "Near Morbidity": A Candid Appraisal of an Early Case Series.

Authors:  Bradley A Gross; Ashutosh P Jadhav; Tudor G Jovin; Brian T Jankowitz
Journal:  Interv Neurol       Date:  2018-07-11
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.