Comparison of virtual unenhanced CT images of the abdomen under different iodine flow rates.

Yongrui Li1, Ye Li1, Alan Jackson2, Xiaodong Li1, Ning Huang3, Chunjie Guo1, Huimao Zhang4.   

Abstract

OBJECTIVE: To assess the effect of varying iodine flow rate (IFR) and iodine concentration on the quality of virtual unenhanced (VUE) images of the abdomen obtained with dual-energy CT.
METHODS: 94 subjects underwent unenhanced and triphasic contrast-enhanced CT scan of the abdomen, including arterial phase, portal venous phase, and delayed phase using dual-energy CT. Patients were randomized into 4 groups with different IFRs or iodine concentrations. VUE images were generated at 70 keV. The CT values, image noise, SNR and CNR of aorta, portal vein, liver, liver lesion, pancreatic parenchyma, spleen, erector spinae, and retroperitoneal fat were recorded. Dose-length product and effective dose for an examination with and without plain phase scan were calculated to assess the potential dose savings. Two radiologists independently assessed subjective image quality using a five-point scale. The Kolmogorov-Smirnov test was used first to test for normal distribution. Where data conformed to a normal distribution, analysis of variance was used to compare mean HU values, image noise, SNRs and CNRs for the 4 image sets. Where data distribution was not normal, a nonparametric test (Kruskal-Wallis test followed by stepwise step-down comparisons) was used. The significance level for all tests was 0.01 (two-sided) to allow for type 2 errors due to multiple testing.
RESULTS: The CT numbers (HU) of VUE images showed no significant differences between the 4 groups (p > 0.05) or between different phases within the same group (p > 0.05). VUE images had equal or higher SNR and CNR than true unenhanced images. VUE images received equal or lower subjective image quality scores than unenhanced images but were of acceptable quality for diagnostic use. Calculated dose-length product and estimated dose showed that the use of VUE images in place of unenhanced images would be associated with a dose saving of 25%.
CONCLUSIONS: VUE images can replace conventional unenhanced images. VUE images are not affected by varying iodine flow rates and iodine concentrations, and diagnostic examinations could be acquired with a potential dose saving of 25%.

Entities:  

Keywords:  Computer tomography; Iodine flow rate; Material-suppressed iodine; Virtual unenhanced imaging

Mesh:

Substances:

Year:  2017        PMID: 27470507     DOI: 10.1007/s00261-016-0842-4

Source DB:  PubMed          Journal:  Abdom Radiol (NY)


  4 in total

1.  The presence of contrast agent increases organ radiation dose in contrast-enhanced CT.

Authors:  Mahta Mazloumi; Gert Van Gompel; Veerle Kersemans; Johan de Mey; Nico Buls
Journal:  Eur Radiol       Date:  2021-03-30       Impact factor: 5.315

2.  Does dual-energy abdominal computed tomography increase the radiation dose to patients: a prospective observational study.

Authors:  Dilip John; Athira R; Swathigha Selvaraj; Rupa Renganathan; Kannan Gunasekaran; Venkatesh Kasi Arunachalam
Journal:  Pol J Radiol       Date:  2021-04-15

3.  Quantitative benchmarking of iodine imaging for two CT spectral imaging technologies: a phantom study.

Authors:  Vanja Harsaker; Kristin Jensen; Hilde Kjernlie Andersen; Anne Catrine Martinsen
Journal:  Eur Radiol Exp       Date:  2021-06-23

Review 4.  Benefits of Low-Dose CT Scan of Head for Patients With Intracranial Hemorrhage.

Authors:  Dan Wu; Gang Wang; Bingyang Bian; Zhuohang Liu; Dan Li
Journal:  Dose Response       Date:  2020-03-06       Impact factor: 2.658

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.