Literature DB >> 27469171

Impact of implant-abutment connection on osteoimmunological and microbiological parameters in short implants: a randomized controlled clinical trial.

Veli Özgen Öztürk1, Gülnur Emingil2, Nagihan Bostanci3,4, Georgios N Belibasakis3,4.   

Abstract

OBJECTIVES: The study aimed to determine the levels of soluble receptor activator of nuclear factor-кB ligand (sRANKL) and osteoprotegerin (OPG) as well as their relative calculated ratio in peri-implant crevicular fluid (PICF) obtained around two different types of implant-abutment connection on short implants following a 12-month monitoring period. Moreover, the levels of a number of oral bacterial species were investigated in the corresponding submucosal biofilm samples.
MATERIALS AND METHODS: Thirty short implants were randomly placed in posterior maxillary edentulous sites using a split-mouth design in 15 periodontally healthy subjects. Tapered interference fit (TIF) and taper-integrated screwed-in (TIS) types of implant-abutment connections were selected for investigation. PICF and submucosal biofilm samples were collected 1 month after surgery and repeated 12 months after prosthetic loading. Clinical parameters, including probing depth, dichotomous presence of bleeding on probing, and plaque index, were recorded and digital periapical radiographs were taken at each time point. sRANKL and OPG levels in PICF were analyzed using an enzyme-linked immunosorbent assay. Total bacterial levels, as well as levels of Fusobacterium nucleatum, Porphyromonas gingivalis, Treponema denticola, Tannerella forsythia, Prevotella intermedia, and Streptococcus oralis, were analyzed in the corresponding submucosal biofilm samples using quantitative real-time polymerase chain reaction.
RESULTS: The total amount of sRANKL in TIF implants was 2.64-fold lower than that in TIS implants at baseline (P < 0.001), whereas similar levels were found after 12 months (P > 0.05). Accordingly, OPG and RANKL/OPG ratio were similar between the groups at each time point (P > 0.05). Microbiological results were similar in both groups at each time point (P > 0.05).
CONCLUSION: The results of this longitudinal study suggested that sRANKL and OPG in PICF, as well as microbiological parameters in submucosal biofilms, were similar between TIF and TIS implants, after a 12-month monitoring period, despite early differences in the former. Therefore, the type of implant-abutment connection does not appear to influence longitudinally the levels of osteoimmunological and microbiological markers in the peri-implant tissues of short implants.
© 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  OPG; RANKL; implant-abutment connection; peri-implant crevicular fluid; short implant; submucosal biofilm

Mesh:

Substances:

Year:  2016        PMID: 27469171     DOI: 10.1111/clr.12937

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  2 in total

Review 1.  Oral microbiome and peri-implant diseases: where are we now?

Authors:  Rafał Pokrowiecki; Agnieszka Mielczarek; Tomasz Zaręba; Stefan Tyski
Journal:  Ther Clin Risk Manag       Date:  2017-11-29       Impact factor: 2.423

2.  Comparison of Osteoimmunological and Microbiological Parameters of Extra Short and Longer Implants Loaded in the Posterior Mandible: A Split Mouth Randomized Clinical Study.

Authors:  Bi Lge Karcı; Elif Oncu
Journal:  Acta Stomatol Croat       Date:  2021-09
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.