OBJECTIVE: The purpose of this study was to compare the effectiveness of an outpatient renal dose adjustment alert via a computerized provider order entry (CPOE) clinical decision support system (CDSS) versus a CDSS with alerts made to dispensing pharmacists. METHODS: This was a retrospective analysis of patients with renal impairment and 30 medications that are contraindicated or require dose-adjustment in such patients. The primary outcome was the rate of renal dosing errors for study medications that were dispensed between August and December 2013, when a pharmacist-based CDSS was in place, versus August through December 2014, when a prescriber-based CDSS was in place. A dosing error was defined as a prescription for one of the study medications dispensed to a patient where the medication was contraindicated or improperly dosed based on the patient's renal function. The denominator was all prescriptions for the study medications dispensed during each respective study period. RESULTS: During the pharmacist- and prescriber-based CDSS study periods, 49,054 and 50,678 prescriptions, respectively, were dispensed for one of the included medications. Of these, 878 (1.8%) and 758 (1.5%) prescriptions were dispensed to patients with renal impairment in the respective study periods. Patients in each group were similar with respect to age, sex, and renal function stage. Overall, the five-month error rate was 0.38%. Error rates were similar between the two groups: 0.36% and 0.40% in the pharmacist- and prescriber-based CDSS, respectively (p=0.523). The medication with the highest error rate was dofetilide (0.51% overall) while the medications with the lowest error rate were dabigatran, fondaparinux, and spironolactone (0.00% overall). CONCLUSIONS: Prescriber- and pharmacist-based CDSS provided comparable, low rates of potential medication errors. Future studies should be undertaken to examine patient benefits of the prescriber-based CDSS.
OBJECTIVE: The purpose of this study was to compare the effectiveness of an outpatient renal dose adjustment alert via a computerized provider order entry (CPOE) clinical decision support system (CDSS) versus a CDSS with alerts made to dispensing pharmacists. METHODS: This was a retrospective analysis of patients with renal impairment and 30 medications that are contraindicated or require dose-adjustment in such patients. The primary outcome was the rate of renal dosing errors for study medications that were dispensed between August and December 2013, when a pharmacist-based CDSS was in place, versus August through December 2014, when a prescriber-based CDSS was in place. A dosing error was defined as a prescription for one of the study medications dispensed to a patient where the medication was contraindicated or improperly dosed based on the patient's renal function. The denominator was all prescriptions for the study medications dispensed during each respective study period. RESULTS: During the pharmacist- and prescriber-based CDSS study periods, 49,054 and 50,678 prescriptions, respectively, were dispensed for one of the included medications. Of these, 878 (1.8%) and 758 (1.5%) prescriptions were dispensed to patients with renal impairment in the respective study periods. Patients in each group were similar with respect to age, sex, and renal function stage. Overall, the five-month error rate was 0.38%. Error rates were similar between the two groups: 0.36% and 0.40% in the pharmacist- and prescriber-based CDSS, respectively (p=0.523). The medication with the highest error rate was dofetilide (0.51% overall) while the medications with the lowest error rate were dabigatran, fondaparinux, and spironolactone (0.00% overall). CONCLUSIONS: Prescriber- and pharmacist-based CDSS provided comparable, low rates of potential medication errors. Future studies should be undertaken to examine patient benefits of the prescriber-based CDSS.
Entities:
Keywords:
Renal insufficiency; clinical decision support systems; computerized provider order entry; medication errors; pharmacists
Authors: Kevin M Terrell; Anthony J Perkins; Siu L Hui; Christopher M Callahan; Paul R Dexter; Douglas K Miller Journal: Ann Emerg Med Date: 2010-05-10 Impact factor: 5.721
Authors: Davy Tawadrous; Salimah Z Shariff; R Brian Haynes; Arthur V Iansavichus; Arsh K Jain; Amit X Garg Journal: Am J Kidney Dis Date: 2011-09-23 Impact factor: 8.860
Authors: Bharati Bhardwaja; Nikki M Carroll; Marsha A Raebel; Elizabeth A Chester; Eli J Korner; Bob E Rocho; David W Brand; David J Magid Journal: Pharmacotherapy Date: 2011-04 Impact factor: 4.705
Authors: Lesley A Stevens; Thomas D Nolin; Michelle M Richardson; Harold I Feldman; Julia B Lewis; Roger Rodby; Raymond Townsend; Aghogho Okparavero; Yaping Lucy Zhang; Christopher H Schmid; Andrew S Levey Journal: Am J Kidney Dis Date: 2009-05-17 Impact factor: 8.860
Authors: Insook Cho; Sarah P Slight; Karen C Nanji; Diane L Seger; Nivethietha Maniam; Patricia C Dykes; David W Bates Journal: BMC Nephrol Date: 2014-12-15 Impact factor: 2.388
Authors: Syed Imran Ali; Su Woong Jung; Hafiz Syed Muhammad Bilal; Sang-Ho Lee; Jamil Hussain; Muhammad Afzal; Maqbool Hussain; Taqdir Ali; Taechoong Chung; Sungyoung Lee Journal: Int J Environ Res Public Health Date: 2021-12-26 Impact factor: 3.390