Literature DB >> 27465342

Establishment of reference intervals and transfusion criterion for Sonoclot analysis.

Zhen-Lu Zhang1, You-Ping Chen2, Cui-Hua Tao3, Xiao-Hui Liu4, Meng-Ya Li5, Xin Zhou6.   

Abstract

Sonoclot analyzer has been widely used in many countries. But the reference intervals provided by the manufacturer were derived from only 45 participants, and there was no cut-off value for transfusion for Sonoclot analysis. This study aimed to establish reference intervals and transfusion criterion for Sonoclot analysis. Volunteers were recruited from healthy Chinese adults and patients undergoing cardiac surgery. Blood samples were withdrawn from forearm vein and measured for activated clotting time (ACT), clot rate (CR), platelet function (PF), activated partial thromboplastin time (APTT), fibrinogen concentration (FIB), and platelet count (PLT). The reference intervals were determined by the nonparametric method. Cut-off values were determined by the receiver operating characteristics curve. A total of 135 healthy volunteers and 281 patients were enrolled. The 95% reference intervals were 96-195 s, 22-51 signal U/min, >1.6 for ACT, CR, PF respectively. In the 281 patients, the results of APTT, FIB, PLT, ACT, CR, and PF ranged from 20.5-300.0 s, 0.28-4.11 g/L, (19.0-387.3)×109/L, 80-514 s, 2.9-74 signal U/min, and 0.1-5.1 respectively. The cut-off values for transfusion were >208, ≤14, and ≤1.3 for ACT, CR, PF respectively. The cut-off values of Sonoclot analysis were within the manufacturer's reference intervals, while they were outside the reference intervals established in this study. The results suggested that the manufacturer's reference intervals were not suitable for Chinese. The reference intervals and cut-off values established in this study will be helpful to Chinese patients.

Entities:  

Keywords:  Sonoclot analyzer; reference interval; transfusion criterion

Mesh:

Substances:

Year:  2016        PMID: 27465342     DOI: 10.1007/s11596-016-1634-3

Source DB:  PubMed          Journal:  J Huazhong Univ Sci Technolog Med Sci        ISSN: 1672-0733


  8 in total

1.  Haemostasis monitoring during sequential aortic valve replacement and liver transplantation.

Authors:  E Sieders; F De Somer; S Bouchez; L Szegedi; Y Van Belleghem; I Colle; R Troisi
Journal:  Acta Gastroenterol Belg       Date:  2010 Jan-Mar       Impact factor: 1.316

2.  Monitoring of low molecular weight heparin anticoagulation during haemodialysis with a Sonoclot Analyzer.

Authors:  Ulf Schött; Lars Göran Nilsson; Marcus Broman; Martin Engström
Journal:  Perfusion       Date:  2010-06-08       Impact factor: 1.972

3.  Comparison of Thromboelastograph and Sonoclot coagulation analyzer for assessing coagulation status during orthotopic liver transplantation.

Authors:  J W Chapin; G L Becker; B J Hulbert; M C Newland; D J Cuka; R P Wood; B W Shaw
Journal:  Transplant Proc       Date:  1989-06       Impact factor: 1.066

4.  Assessment of heparin anticoagulation by Sonoclot Analyzer in arterial reconstruction surgery.

Authors:  Bok Lee; Noori Al-Waili; Glenn Butler; Khelod Salom
Journal:  Technol Health Care       Date:  2011       Impact factor: 1.285

5.  Coagulation tests predict bleeding after cardiopulmonary bypass.

Authors:  G A Nuttall; W C Oliver; M H Ereth; P J Santrach
Journal:  J Cardiothorac Vasc Anesth       Date:  1997-12       Impact factor: 2.628

6.  [Blood coagulation monitoring during liver transplantation: Sonoclot analysis and laboratory tests].

Authors:  M L Bindi; G D Biancofiore; G Consani; F Cellai; N Cecconi; A Romanelli; F Filipponi; F Mosca; G Amorese; A Vagelli
Journal:  Minerva Anestesiol       Date:  2001-05       Impact factor: 3.051

7.  Evaluation of platelet function by Sonoclot analysis compared with other hemostatic variables in cardiac surgery.

Authors:  T Miyashita; M Kuro
Journal:  Anesth Analg       Date:  1998-12       Impact factor: 5.108

8.  Impact of Sonoclot hemostasis analysis after cardiopulmonary bypass on postoperative hemorrhage in cardiac surgery.

Authors:  Tatsuya Yamada; Nobuyuki Katori; Kenichi A Tanaka; Junzo Takeda
Journal:  J Anesth       Date:  2007-05-30       Impact factor: 2.078

  8 in total
  1 in total

1.  Chinese expert consensus on diagnosis and treatment of coagulation dysfunction in COVID-19.

Authors:  Jing-Chun Song; Gang Wang; Wei Zhang; Yang Zhang; Wei-Qin Li; Zhou Zhou
Journal:  Mil Med Res       Date:  2020-04-20
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.