Literature DB >> 27465030

Provider risk factors for medication administration error alerts: analyses of a large-scale closed-loop medication administration system using RFID and barcode.

Yeonsoo Hwang1,2, Dukyong Yoon1, Eun Kyoung Ahn1, Hee Hwang2, Rae Woong Park1.   

Abstract

PURPOSE: To determine the risk factors and rate of medication administration error (MAE) alerts by analyzing large-scale medication administration data and related error logs automatically recorded in a closed-loop medication administration system using radio-frequency identification and barcodes.
METHODS: The subject hospital adopted a closed-loop medication administration system. All medication administrations in the general wards were automatically recorded in real-time using radio-frequency identification, barcodes, and hand-held point-of-care devices. MAE alert logs recorded during a full 1 year of 2012. We evaluated risk factors for MAE alerts including administration time, order type, medication route, the number of medication doses administered, and factors associated with nurse practices by logistic regression analysis.
RESULTS: A total of 2 874 539 medication dose records from 30 232 patients (882.6 patient-years) were included in 2012. We identified 35 082 MAE alerts (1.22% of total medication doses). The MAE alerts were significantly related to administration at non-standard time [odds ratio (OR) 1.559, 95% confidence interval (CI) 1.515-1.604], emergency order (OR 1.527, 95%CI 1.464-1.594), and the number of medication doses administered (OR 0.993, 95%CI 0.992-0.993). Medication route, nurse's employment duration, and working schedule were also significantly related.
CONCLUSION: The MAE alert rate was 1.22% over the 1-year observation period in the hospital examined in this study. The MAE alerts were significantly related to administration time, order type, medication route, the number of medication doses administered, nurse's employment duration, and working schedule. The real-time closed-loop medication administration system contributed to improving patient safety by preventing potential MAEs.
Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

Entities:  

Keywords:  closed-loop medication administration; medication error; patient safety; pharmacoepidemiology; point-of-care system; radio-frequency identification (RFID)

Mesh:

Substances:

Year:  2016        PMID: 27465030     DOI: 10.1002/pds.4068

Source DB:  PubMed          Journal:  Pharmacoepidemiol Drug Saf        ISSN: 1053-8569            Impact factor:   2.890


  4 in total

1.  Implementation and Evaluation of a RFID Smart Cabinet to Improve Traceability and the Efficient Consumption of High Cost Medical Supplies in a Large Hospital.

Authors:  María Del Carmen León-Araujo; Elisa Gómez-Inhiesto; María Teresa Acaiturri-Ayesta
Journal:  J Med Syst       Date:  2019-05-10       Impact factor: 4.460

2.  Systemic Defenses to Prevent Intravenous Medication Errors in Hospitals: A Systematic Review.

Authors:  Sini Karoliina Kuitunen; Ilona Niittynen; Marja Airaksinen; Anna-Riia Holmström
Journal:  J Patient Saf       Date:  2021-12-01       Impact factor: 2.243

3.  Adoption rates of electronic health records in Turkish Hospitals and the relation with hospital sizes.

Authors:  Ilker Kose; John Rayner; Suayip Birinci; Mustafa Mahir Ulgu; Ismayil Yilmaz; Seyma Guner
Journal:  BMC Health Serv Res       Date:  2020-10-21       Impact factor: 2.655

4.  Impact of Medication Regimen Simplification on Medication Incidents in Residential Aged Care: SIMPLER Randomized Controlled Trial.

Authors:  Nicolas Dugré; J Simon Bell; Ria E Hopkins; Jenni Ilomäki; Esa Y H Chen; Megan Corlis; Jan Van Emden; Michelle Hogan; Janet K Sluggett
Journal:  J Clin Med       Date:  2021-03-06       Impact factor: 4.241

  4 in total