Literature DB >> 27462262

The Effect of a Diving Mask on Intraocular Pressure in a Healthy Population.

Catherina Josephine Goenadi1, David Zhiwei Law2, Jia Wen Lee1, Ee Lin Ong1, Wai Kitt Chee1, Jason Cheng1.   

Abstract

PURPOSE: Swimming goggles increase the intraocular pressure (IOP) via the periorbital frame pressure and suction effect. In comparison, diving masks have a larger frame rim and incorporate the nose. The exact effect(s) of diving masks on IOP is unknown. This study evaluates the influence of diving masks on IOP in normal, healthy subjects.
METHODS: Tonometry was performed in both eyes of all subjects with an AVIA(®)Tono-Pen by a single investigator. Measurements were taken at baseline without the diving mask and with the subjects wearing a small-volume, double-window diving mask, but with the mask lenses removed. Two IOP readings in each eye were measured, and an additional reading was measured if the difference between the initial 2 was ≥2 mm Hg. Central corneal thickness (CCT) was also measured in each eye, using a contact pachymeter (OcuScan(®)Alcon).
RESULTS: Forty eyes of 20 healthy volunteers (age 29.7 ± 9.3 years; range 21-52) were included. The mean CCT was 544.4 ± 43.5 µm. The mean IOP before the diving mask was worn had been 17.23 ± 2.18 mm Hg (n = 40). The IOP decreased by 0.43 mm Hg (p $1003c; 0.05) to 16.80 ± 2.57 mm Hg after the diving mask had been put on. There was no correlation between IOP change and age (r = 0.143, p = 0.337), gender (r = -0.174, p = 0.283) or CCT (r = -0.123, p = 0.445).
CONCLUSION: There was no increase in IOP after the diving mask had been worn. A small but statistically significant decrease in IOP was observed. This study demonstrates that unlike swimming goggles, the strap tension and frame pressure on the periorbital tissue from a diving mask does not increase IOP. Diving masks may be a suitable alternative to swimming goggles for patients with advanced glaucoma or glaucoma filtration surgery.

Entities:  

Keywords:  Diving mask; Glaucoma; Intraocular pressure; Swimming goggles

Year:  2016        PMID: 27462262      PMCID: PMC4943308          DOI: 10.1159/000446423

Source DB:  PubMed          Journal:  Case Rep Ophthalmol        ISSN: 1663-2699


Introduction

Glaucoma is the leading cause of irreversible blindness worldwide according to the World Health Organization [1]. An elevated intraocular pressure (IOP) is widely regarded as a significant risk factor for glaucoma development and progression [2, 3]. Recreational scuba diving is an increasingly popular sport, and the professional association of diving instructors (PADI) has issued over 14 million diver certifications in the last 16 years [4]. Diving can affect the IOP in a number of ways; firstly from the change in the internal mask air pressure at different underwater depths, secondly from the inhaling or exhaling from the nose, and thirdly through the diving mask itself. The first and second factors can be controlled by the diver by exhaling from the nose during descent, also known as equalizing the mask pressure. Senn et al. [5] found that diving mask pressure spikes were less common in experienced divers compared to beginners. Failing to equalize the diving mask pressure can lead to ocular barotrauma, which ranges from lid edema, ecchymosis and subconjunctival hemorrhage to more serious injuries such as hyphema and subperiosteal orbital hemorrhage [6, 7]. The diving mask itself may also affect the IOP. Swimming goggles are known to increase the IOP, with larger-frame goggles having less effect than smaller-frame ones [8910]. To our knowledge, the effect of diving masks on IOP is still currently unknown. Our study evaluates the influence of diving masks on IOP in normal healthy subjects.

Materials and Methods

We recruited 20 normal healthy subjects with no existing ocular condition. Tonometry was performed in both eyes of all subjects with an AVIA®Tono-Pen (Reichert Technologies, Depew, N.Y., USA) by a single investigator. Measurements were taken at baseline without the diving mask and with the subjects wearing a small-volume, double-window diving mask, but with the mask lenses removed (fig. 1). One drop of tetracaine was instilled in both eyes 2 min prior to the first reading. IOP was measured in a sitting position with the subject in primary gaze, and the participants were allowed to blink between the individual measurements. Two IOP readings in each eye were measured, and an additional reading was measured if the difference between the initial 2 was ≥2 mm Hg. We obtained the mean of these readings. Central corneal thickness (CCT) was also measured in each eye using a contact pachymeter (OcuScan®Alcon; Alcon, Fort Worth, Tex., USA).
Fig. 1

Photograph of the dive mask used in our study with the mask lenses removed.

Statistical analysis was performed using SPSS 22.0 software (SPSS Inc., Chicago, Ill., USA). IOP measurements from both eyes were used in this study, and the Shapiro-Wilk test was first used to demonstrate that the data were normally distributed. Differences between IOP measurements with and without the diving mask were evaluated using the paired t test. Pearson correlation coefficients were used to analyze the relationship between IOP change and age, gender or CCT. We considered a p value <0.05 statistically significant.

Results

Twenty subjects, 12 females and 8 males, with a mean age of 29.7 ± 9.3 years were recruited for this study. As both eyes of each study subject were considered, we analyzed a total of 40 eyes. The mean CCT was 544.4 ± 43.5 µm. The mean IOP before the diving mask was worn was 17.23 ± 2.18 mm Hg (n = 40). The IOP decreased by 0.43 mm Hg (p < 0.05) to 16.80 ± 2.57 mm Hg after the diving mask had been put on. The scatter plot of IOP measurements before and after donning of the diving mask is illustrated (fig. 2). There was no correlation between IOP change and age (r = 0.143, p = 0.337), gender (r = −0.174, p = 0.283) or CCT (r = −0.123, p = 0.445).
Fig. 2

Scatter plot illustrating the IOP measurements before and after donning of the diving mask.

Discussion

The effect of donning of a diving mask on IOP and hence its significance to divers with glaucoma is not well addressed in the ophthalmic literature. Our study, although not performed while diving, shows that there was no increase in IOP after the diving mask had been worn. Although we found a 0.43 mm Hg decrease in IOP when the diving mask was worn, this value was within the margin of error of Tono-Pen AVIA® [11], and thus this decrease of IOP, although statistically significant in our study, was not clinically significant. Swimming goggles are known to increase the IOP, and Morgan et al. [8] concluded that smaller swimming goggle frames had a greater effect on IOP than larger frames. They postulated that the headband tension of the swimming goggles transmitted into the orbit through the rubber seal increases orbital tissue pressure, compressing the globe and leading to the sustained IOP rise observed. This theory is consistent with our findings, as a larger diving mask frame that sits on the bony orbit will exert less pressure on the periocular soft tissue and have less effect on the IOP. Another difference between swimming goggles and a diving mask is that the nose is also enclosed in the latter. Inhaling and exhaling through the nose changes the internal pressure of the mask; therefore, the suction effect seen in swimming goggles would not apply to a diving mask. Although a different mask design could have a different effect on IOP, the diving mask we chose was that of a small-volume design. As such, we may extrapolate our finding to other diving masks of intermediate- or large-volume designs, as these would exert less pressure on the periorbital tissue due to their larger size frames, and hence wearing them would probably not result in any increase in IOP. Based on the finding from our study, we would therefore propose that a diving mask may be a suitable alternative to swimming goggles for patients with advanced glaucoma or glaucoma filtration surgery. This study simulated only partial effects of the scuba diving mask because we removed the lenses to allow IOP measurement that resulted in the loss of an airtight seal and eliminated the usual suction effect. This study also did not look at the effects of the change in underwater mask air pressure at different water depths. Although Senn et al. [5] found that pressure equalization of a regular mask would prevent large IOP spikes, the pressure difference between the inside and outside of the mask still fluctuated by 19 mm Hg, parallel to respiration. It is not known how different diving mask designs may affect the fluctuations of pressure difference between the inside and outside of the diving masks and hence what long-term effect this can have on ocular tissues. Future studies could potentially be carried out in a hyperbaric chamber to simulate the underwater effects. In addition, a longitudinal study looking at the effects of regular diving in healthy subjects and glaucoma patients may help determine long-term impacts of these pressure fluctuations on the optic nerve.

Statement of Ethics

Informed consent was obtained from all subjects. The study was approved by National Healthcare Group Domain Specific Review Board and was performed in accordance with the Declaration of Helsinki.

Disclosure Statement

This study was supported by a grant from The Alexandra Health Enabling Grant, Alexandra Health, Singapore. All the authors report no financial disclosures.
  10 in total

1.  Case of normal tension glaucoma induced or exacerbated by wearing swimming goggles.

Authors:  Min Hye Kang; William H Morgan; Chandrakumar Balaratnasingam; Con Anastas; Dao-Yi Yu
Journal:  Clin Exp Ophthalmol       Date:  2010-05       Impact factor: 4.207

2.  Swimming goggles and elevated intraocular pressure.

Authors:  C E Starr; N M Radcliffe
Journal:  Br J Ophthalmol       Date:  2009-05       Impact factor: 4.638

3.  Wearing swimming goggles can elevate intraocular pressure.

Authors:  W H Morgan; T S Cunneen; C Balaratnasingam; D-Y Yu
Journal:  Br J Ophthalmol       Date:  2008-07-11       Impact factor: 4.638

4.  Intraocular pressure and glaucoma.

Authors:  A Sommer
Journal:  Am J Ophthalmol       Date:  1989-02-15       Impact factor: 5.258

5.  [Ocular barostress and barotrauma. A study of 15 scuba divers].

Authors:  P Senn; U Helfenstein; M L Senn; M K Schmid; I Schipper
Journal:  Klin Monbl Augenheilkd       Date:  2001-04       Impact factor: 0.700

6.  The number of people with glaucoma worldwide in 2010 and 2020.

Authors:  H A Quigley; A T Broman
Journal:  Br J Ophthalmol       Date:  2006-03       Impact factor: 4.638

7.  Ocular barotrauma caused by mask squeeze during a scuba dive.

Authors:  F W Rudge
Journal:  South Med J       Date:  1994-07       Impact factor: 0.954

8.  Orbital subperiosteal hemorrhage while scuba diving.

Authors:  Isabel Gómez-Ledesma; Enrique Mencía-Gutíerrez; Esperanza Gutiérrez-Díaz; María A Alonso-Santiago
Journal:  Orbit       Date:  2006-03

Review 9.  Factors for progression and glaucoma treatment: the Early Manifest Glaucoma Trial.

Authors:  M Cristina Leske; Anders Heijl; Leslie Hyman; Bo Bengtsson; Eugene Komaroff
Journal:  Curr Opin Ophthalmol       Date:  2004-04       Impact factor: 3.761

10.  Repeatability of intraocular pressure measurements with Icare PRO rebound, Tono-Pen AVIA, and Goldmann tonometers in sitting and reclining positions.

Authors:  Caterina Schweier; James V M Hanson; Jens Funk; Marc Töteberg-Harms
Journal:  BMC Ophthalmol       Date:  2013-09-05       Impact factor: 2.209

  10 in total
  1 in total

1.  Effect of SCUBA Diving on Ophthalmic Parameters.

Authors:  Laurent Deleu; Janet Catherine; Laurence Postelmans; Costantino Balestra
Journal:  Medicina (Kaunas)       Date:  2022-03-09       Impact factor: 2.430

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.