Literature DB >> 27460313

Evaluation of metal-ceramic bond characteristics of three dental Co-Cr alloys prepared with different fabrication techniques.

Hongmei Wang1, Qing Feng2, Ning Li3, Sheng Xu4.   

Abstract

STATEMENT OF PROBLEM: Limited information is available regarding the metal-ceramic bond strength of dental Co-Cr alloys fabricated by casting (CAST), computer numerical control (CNC) milling, and selective laser melting (SLM).
PURPOSE: The purpose of this in vitro study was to evaluate the metal-ceramic bond characteristics of 3 dental Co-Cr alloys fabricated by casting, computer numerical control milling, and selective laser melting techniques using the 3-point bend test (International Organization for Standardization [ISO] standard 9693).
MATERIAL AND METHODS: Forty-five specimens (25×3×0.5 mm) made of dental Co-Cr alloys were prepared by CAST, CNC milling, and SLM techniques. The morphology of the oxidation surface of metal specimens was evaluated by scanning electron microscopy (SEM). After porcelain application, the interfacial characterization was evaluated by SEM equipped with energy-dispersive spectrometry (EDS) analysis, and the metal-ceramic bond strength was assessed with the 3-point bend test. Failure type and elemental composition on the debonding interface were assessed by SEM/EDS. The bond strength was statistically analyzed by 1-way ANOVA and Tukey honest significant difference test (α=.05).
RESULTS: The oxidation surfaces of the CAST, CNC, and SLM groups were different. They were porous in the CAST group but compact and irregular in the CNC and SLM groups. The metal-ceramic interfaces of the SLM and CNC groups showed excellent combination compared with those of the CAST group. The bond strength was 37.7 ±6.5 MPa for CAST, 43.3 ±9.2 MPa for CNC, and 46.8 ±5.1 MPa for the SLM group. Statistically significant differences were found among the 3 groups tested (P=.028). The debonding surfaces of all specimens exhibited cohesive failure mode.
CONCLUSIONS: The oxidation surface morphologies and thicknesses of dental Co-Cr alloys are dependent on the different fabrication techniques used. The bond strength of all 3 groups exceed the minimum acceptable value of 25 MPa recommended by ISO 9693; hence, dental Co-Cr alloy fabricated with the SLM techniques could be a promising alternative for metal ceramic restorations. Copyright Â
© 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27460313     DOI: 10.1016/j.prosdent.2016.06.002

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  9 in total

Review 1.  A review of current challenges and prospects of magnesium and its alloy for bone implant applications.

Authors:  Meysam Nasr Azadani; Abolfazl Zahedi; Oluwole Kingsley Bowoto; Bankole Ibrahim Oladapo
Journal:  Prog Biomater       Date:  2022-03-03

2.  Evaluation of the Bond Strengths between Dental Porcelain and Cobalt-Chromium Metal Frameworks Manufactured with Different Techniques after the Thermal Aging Process.

Authors:  Elif Ece Yoldan; Nurullah Türker; Ulviye Ş Büyükkaplan; Mehmet M Özarslan; Recep Karalı; Ahmet T Deniz
Journal:  Scanning       Date:  2020-04-29       Impact factor: 1.932

3.  The Effect of Multiple Firings on the Shear Bond Strength of Porcelain to a New Millable Alloy and a Conventional Casting Alloy.

Authors:  Mitra Farzin; Rashin Giti; Amin Asalforush-Rezaiye
Journal:  Materials (Basel)       Date:  2018-03-22       Impact factor: 3.623

4.  Evaluation of corrosion resistance of Co-Cr alloys fabricated with different metal laser sintering systems.

Authors:  Süleyman Hakan Tuna; Erhan Karaca; İsmail Aslan; Gürel Pekkan; Nuran Özçiçek Pekmez
Journal:  J Adv Prosthodont       Date:  2020-06-18       Impact factor: 1.904

5.  Effect of Recasting on Physical Properties of Base Metal Alloys: An In Vitro Study.

Authors:  Jittin James; Jose Julian; J Rahul; Gibi Babu Philip; Jinsa P Devassy; P B Reba
Journal:  J Int Soc Prev Community Dent       Date:  2018-10-08

6.  Discrepancy in alloy composition of imported and non-imported porcelain-fused-to-metal (PFM) crowns produced by Norwegian dental laboratories.

Authors:  Håvard Jostein Haugen; Brandon Michael Soltvedt; Peter N Nguyen; Hans Jacob Ronold; Gaute Floer Johnsen
Journal:  Biomater Investig Dent       Date:  2020-02-11

7.  Fracture Load of CAD/CAM Fabricated Cantilever Implant-Supported Zirconia Framework: An In Vitro Study.

Authors:  Ibraheem F Alshiddi; Syed Rashid Habib; Muhammad Sohail Zafar; Salwa Bajunaid; Nawaf Labban; Mohammed Alsarhan
Journal:  Molecules       Date:  2021-04-13       Impact factor: 4.411

8.  Influence of Manufacturing Methods of Implant-Supported Crowns on External and Internal Marginal Fit: A Micro-CT Analysis.

Authors:  Izabela C M Moris; Silas Borges Monteiro; Raíssa Martins; Ricardo Faria Ribeiro; Erica A Gomes
Journal:  Biomed Res Int       Date:  2018-01-23       Impact factor: 3.411

9.  Comparative Analysis of Mechanical Properties and Metal-Ceramic Bond Strength of Co-Cr Dental Alloy Fabricated by Different Manufacturing Processes.

Authors:  Xingting Han; Tomofumi Sawada; Christine Schille; Ernst Schweizer; Lutz Scheideler; Jürgen Geis-Gerstorfer; Frank Rupp; Sebastian Spintzyk
Journal:  Materials (Basel)       Date:  2018-09-22       Impact factor: 3.623

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.