Analysis of the application of the generalized monod kinetics model to describe the human corneal oxygen-consumption rate during soft contact lens wear.

V Compañ1, M Aguilella-Arzo2, L F Del Castillo3, S I Hernández4, J M Gonzalez-Meijome5.   

Abstract

This work is an analysis of the application of the generalized Monod kinetics model describing human corneal oxygen consumption during soft contact lens wear to models previously used by Chhabra et al. (J Biomed Mater Res B Appl Biomater, 2009a;90:202-209, Optom Vis Sci 2009b;86:454-466) and Larrea and Büchler (Invest Ophthalmol Vis Sci 2009;50:1076-1080). We use oxygen tension from in vivo estimations provided by Bonanno [Bonanno et al., Invest Ophthalmol Vis Sci 2002;43:371-376, and Bonanno et al 2009]. We consider four hydrogel and six silicone hydrogel lenses. The cornea is considered a single homogeneous layer, with constant oxygen permeability regardless of the type of lens worn. Our calculations yield different values for the maximum oxygen consumption rate Qc,max , whith differents oxygen tensions (high and low pc ) at the cornea-tears interface. Surprisingly, for both models, we observe an increase in oxygen consumption near an oxygen tension of 105 mmHg until a maximum is reached, then decreasing for higher levels of oxygen pressure. That is, when lowering the pressure of oxygen, the parameter Qc,max initially increases depending on the intensity of the change in pressure. Which, it could be related with the variation of the pH. Furthermore, it is also noted that to greater reductions in pressure, this parameter decreases, possibly due to changes in the concentration of glucose related to the anaerobic respiration. The averaged in vivo human corneal oxygen consumption rate of 1.47 × 10-4 cm3 of O2 /cm3 tissue s, with Monod kinetics model, considering all the lenses studied, is smaller than the average oxygen consumption rate value obtained using the Larrea and Büchler model. The impact that these calculations have on the oxygen partial pressure available at different depths in the corneal tissue is presented and discussed, taking into consideration previous models used in this study.
© 2016 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 105B: 2269-2281, 2017. © 2016 Wiley Periodicals, Inc.

Entities:  

Keywords:  Monod kinetics model; cornea; oxygen consumption; oxygen tension; soft contact lenses

Mesh:

Substances:

Year:  2016        PMID: 27459544     DOI: 10.1002/jbm.b.33764

Source DB:  PubMed          Journal:  J Biomed Mater Res B Appl Biomater        ISSN: 1552-4973            Impact factor:   3.368


  2 in total

1.  Simulation of time-fractional oxygen diffusion in cornea coated by contact-lens.

Authors:  Alireza Daneh-Dezfuli; Mohammad Reza Zarei; Mehdi Jalalvand; Reza Bahoosh
Journal:  Mech Time Depend Mater       Date:  2022-03-09       Impact factor: 2.143

2.  A refined model on flow and oxygen consumption in the human cornea depending on the oxygen tension at the interface cornea/post lens tear film during contact lens wear.

Authors:  Vicente Compañ Moreno; Marcel Aguilella-Arzo; Roxana M Del Castillo; Francisco J Espinós; Luis Felipe Del Castillo
Journal:  J Optom       Date:  2021-02-13
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.