Literature DB >> 27457915

Wearable Lactate Threshold Predicting Device is Valid and Reliable in Runners.

Nattai R Borges1, Matthew W Driller.   

Abstract

Borges, NR and Driller, MW. Wearable lactate threshold predicting device is valid and reliable in runners. J Strength Cond Res 30(8): 2212-2218, 2016-A commercially available device claiming to be the world's first wearable lactate threshold predicting device (WLT), using near-infrared LED technology, has entered the market. The aim of this study was to determine the levels of agreement between the WLT-derived lactate threshold workload and traditional methods of lactate threshold (LT) calculation and the interdevice and intradevice reliability of the WLT. Fourteen (7 male, 7 female; mean ± SD; age: 18-45 years, height: 169 ± 9 cm, mass: 67 ± 13 kg, V[Combining Dot Above]O2max: 53 ± 9 ml·kg·min) subjects ranging from recreationally active to highly trained athletes completed an incremental exercise test to exhaustion on a treadmill. Blood lactate samples were taken at the end of each 3-minute stage during the test to determine lactate threshold using 5 traditional methods from blood lactate analysis which were then compared against the WLT predicted value. In a subset of the population (n = 12), repeat trials were performed to determine both inter-reliability and intrareliability of the WLT device. Intraclass correlation coefficient (ICC) found high to very high agreement between the WLT and traditional methods (ICC > 0.80), with TEMs and mean differences ranging between 3.9-10.2% and 1.3-9.4%. Both interdevice and intradevice reliability resulted in highly reproducible and comparable results (CV < 1.2%, TEM <0.2 km·h, ICC > 0.97). This study suggests that the WLT is a practical, reliable, and noninvasive tool for use in predicting LT in runners.

Entities:  

Mesh:

Substances:

Year:  2016        PMID: 27457915     DOI: 10.1519/JSC.0000000000001307

Source DB:  PubMed          Journal:  J Strength Cond Res        ISSN: 1064-8011            Impact factor:   3.775


  11 in total

Review 1.  Muscle Oximetry in Sports Science: A Systematic Review.

Authors:  Stephane Perrey; Marco Ferrari
Journal:  Sports Med       Date:  2018-03       Impact factor: 11.136

2.  Estimating the Lactate Threshold Using Wireless Near-Infrared Spectroscopy and Threshold Detection Analyses.

Authors:  Trent E Cayot; Shara G Robinson; Lindsay E Davis; Paul A Bender; John R Thistlethwaite; Craig E Broeder; Jakob D Lauver
Journal:  Int J Exerc Sci       Date:  2021-04-01

3.  Integrated Framework of Load Monitoring by a Combination of Smartphone Applications, Wearables and Point-of-Care Testing Provides Feedback that Allows Individual Responsive Adjustments to Activities of Daily Living.

Authors:  Peter Düking; Silvia Achtzehn; Hans-Christer Holmberg; Billy Sperlich
Journal:  Sensors (Basel)       Date:  2018-05-19       Impact factor: 3.576

4.  A Validation Study of a Noninvasive Lactate Threshold Device.

Authors:  Rebecca M McMorries; Dustin P Joubert; Eric J Jones; Mark D Faries
Journal:  Int J Exerc Sci       Date:  2019-01-01

5.  Dose-Response Matters! - A Perspective on the Exercise Prescription in Exercise-Cognition Research.

Authors:  Fabian Herold; Patrick Müller; Thomas Gronwald; Notger G Müller
Journal:  Front Psychol       Date:  2019-11-01

6.  The use of muscle near-infrared spectroscopy (NIRS) to assess the aerobic training loads of world-class rowers.

Authors:  Andrzej Klusiewicz; Kinga Rębiś; Mariusz Ozimek; Adam Czaplicki
Journal:  Biol Sport       Date:  2021-05-20       Impact factor: 4.606

7.  Usefulness of Portable Device to Establish Differences in Muscle Oxygenation Between the Wingate Test and Graded Exercise Test: Effect of Gender on Anaerobic and Aerobic Capacity in Speed Skaters.

Authors:  Kinga Rębiś; Dorota Sadowska; Michal Starczewski; Andrzej Klusiewicz
Journal:  Front Physiol       Date:  2022-03-08       Impact factor: 4.566

8.  Validation of a novel wearable, wireless technology to estimate oxygen levels and lactate threshold power in the exercising muscle.

Authors:  Parisa Farzam; Zack Starkweather; Maria A Franceschini
Journal:  Physiol Rep       Date:  2018-04

Review 9.  A Critical Review of Consumer Wearables, Mobile Applications, and Equipment for Providing Biofeedback, Monitoring Stress, and Sleep in Physically Active Populations.

Authors:  Jonathan M Peake; Graham Kerr; John P Sullivan
Journal:  Front Physiol       Date:  2018-06-28       Impact factor: 4.566

10.  Muscle Oxygenation Unlocks the Secrets of Physiological Responses to Exercise: Time to Exploit it in the Training Monitoring.

Authors:  Stephane Perrey
Journal:  Front Sports Act Living       Date:  2022-03-07
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.