Electrophysiological observations of acute His bundle injury during permanent His bundle pacing.

Pugazhendhi Vijayaraman1, Gopi Dandamudi2, Kenneth A Ellenbogen3.   

Abstract

BACKGROUND: Permanent His bundle pacing (HBP) is a physiological alternative to right ventricular pacing (RVP). Catheter manipulation during HBP can cause trauma to the His bundle during implantation. We sought to determine acute and long-term incidence of His bundle (HB) injury with HBP.
METHODS: Patients undergoing permanent HBP at Geisinger Wyoming Valley Medical Center from 2006 to 2014 formed the study group. Patients with pre-existing His-Purkinje disease (HPD) were excluded from the study. Any development of new bundle branch block (BBB) or AV block (B) during acute HBP lead-induced block was recorded. Resolution of AVB and/or BBB was documented.
RESULTS: HBP was attempted in 450 patients. In 358 patients without HPD, 28 (7.8%) developed acute HB injury in the form of complete AVB (4, 1.1%), RBBB (21, 5.9%) or LBBB (3, 0.8%) during HBP lead placement. In all 7 patients with AVB or LBBB, conduction completely recovered. The HB electrogram from the lead displayed injury current in all 7 patients. Lead-induced RBBB resolved in 12 of 21 patients and persisted in 9 (2.5%) patients. Pacing from the HBP lead resulted in correction of acute conduction block in 27 of 28 patients and 8 of 9 patients with chronic RBBB. None of the patients with transient conduction block developed new conduction disease during follow-up of 21±19months.
CONCLUSIONS: Despite acute trauma to HB in 7.8% of patients undergoing permanent HBP, complete resolution of conduction block occurred in 19 of 28 patients (68%). RBBB persisted in 9 patients (32%) but mostly normalized with HBP.
Copyright © 2016 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Bundle branch block; Complete heart block; His bundle injury; His bundle pacing; Permanent His bundle pacing

Mesh:

Year:  2016        PMID: 27457729     DOI: 10.1016/j.jelectrocard.2016.07.006

Source DB:  PubMed          Journal:  J Electrocardiol        ISSN: 0022-0736            Impact factor:   1.438


  4 in total

1.  In Vitro/Ex Vivo Investigation of Modified Utah Electrode Array to Selectively Sense and Pace the Sub-Surface Cardiac His Bundle.

Authors:  Ankur R Shah; Muhammad S Khan; Annie M Hirahara; Matthias Lange; Ravi Ranjan; Derek J Dosdall
Journal:  ACS Biomater Sci Eng       Date:  2020-05-07

2.  His bundle pacing guided by automated intrinsic morphology matching is feasible in patients with narrow QRS complexes.

Authors:  Dirk Bastian; Caterina Gregorio; Veronica Buia; Janusch Walaschek; Harald Rittger; Laura Vitali-Serdoz
Journal:  Sci Rep       Date:  2022-03-04       Impact factor: 4.379

3.  Painful left bundle branch block [corrected] syndrome treated successfully with permanent His bundle pacing.

Authors:  Prakash G Suryanarayana; David S Frankel; Francis E Marchlinski; Robert D Schaller
Journal:  HeartRhythm Case Rep       Date:  2018-08-14

4.  Reversal of left bundle branch block-induced cardiomyopathy by His bundle pacing.

Authors:  Fei Liu; Lijun Zeng; Xiaomeng Yin; Lianjun Gao; Yunlong Xia; Yingxue Dong
Journal:  J Int Med Res       Date:  2019-11-04       Impact factor: 1.671

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.