| Literature DB >> 27456005 |
Samantha Keogh1,2, Julie Flynn3,4, Nicole Marsh3,4, Gabor Mihala5, Karen Davies4,6, Claire Rickard3,4.
Abstract
BACKGROUND: Research has identified high failure rates of peripheral intravenous catheter (PIVC) and varied flushing practices.Entities:
Keywords: 0.9 % sodium chloride; Catheter obstruction; Flushing; Peripheral; Phlebitis; Randomised controlled trial; Vascular access devices
Mesh:
Substances:
Year: 2016 PMID: 27456005 PMCID: PMC4960789 DOI: 10.1186/s13063-016-1470-6
Source DB: PubMed Journal: Trials ISSN: 1745-6215 Impact factor: 2.279
Fig. 1Participant flowchart
Patient and insertion characteristics at baseline (n = 160)
| Characteristic | Total ( | Flush volume | Flush frequency | ||
|---|---|---|---|---|---|
| 3 mL ( | 10 mL ( | 24 h ( | 6 h ( | ||
| Group size | 160 (100) | 80 (50) | 80 (50) | 79 (49) | 81 (51) |
| Age (median, IQR) | 63 (24) | 63 (22) | 64 (30) | 63 (26) | 64 (23) |
| Gender (male) | 93 (58) | 53 (66) | 40 (50) | 47 (59) | 46 (57) |
| Overweight/obesea | 70 (44) | 33 (41) | 37 (46) | 33 (42) | 37 (46) |
| Comorbidities (≥2) | 110 (69) | 51 (64) | 59 (74) | 57 (72) | 53 (65) |
| Skin integrity (poor) | 24 (15) | 12 (15) | 12 (15) | 12 (15) | 12 (15) |
| Infection (any type) | 43 (27) | 22 (28) | 21 (26) | 18 (23) | 25 (31) |
| Antibiotic treatment | 115 (72) | 57 (71) | 58 (72) | 60 (76) | 55 (68) |
| Frequency of IV txb: | |||||
| - 0 | 15 (11) | 10 (12) | 5 (6) | 8 (10) | 7 (9) |
| - 1–2 times daily | 23 (17) | 10 (12) | 13 (16) | 14 (18) | 9 (11) |
| - 3–4 times daily | 71 (54) | 35 (44) | 36 (45) | 37 (47) | 34 (42) |
| - ≥5 times daily | 23 (17) | 13 (16) | 10 (12) | 8 (10) | 15 (19) |
| Inserted in dominant arm | 80 (52) | 37 (47) | 36 (49) | 36 (48) | 37 (47) |
| Insertion point: | |||||
| - post. wrist | 39 (24) | 22 (28) | 17 (21) | 18 (23) | 21 (26) |
| - hand | 38 (24) | 18 (22) | 20 (25) | 18 (23) | 20 (25) |
| - post. u/l forearm | 30 (19) | 15 (19) | 15 (19) | 17 (22) | 13 (16) |
| - ant. u/l forearm | 29 (18) | 15 (19) | 14 (18) | 14 (18) | 15 (19) |
| - cub. fossa/ant. u arm | 24 (15) | 10 (12) | 14 (18) | 12 (15) | 12 (15) |
| Vein quality (poor) | 85 (53) | 41 (51) | 44 (55) | 39 (49) | 46 (57) |
| Insertion in wardc | 118 (74) | 59 (74) | 59 (74) | 59 (75) | 59 (73) |
| Inserted by: | |||||
| - IV nurse inserter | 72 (45) | 36 (45) | 36 (45) | 39 (49) | 33 (41) |
| - any doctor | 68 (43) | 35 (44) | 33 (41) | 35 (44) | 33 (41) |
| - any nurse/unknown | 20 (13) | 9 (11) | 11 (14) | 5 (6) | 15 (19) |
| Multiple insertion attempts | 32 (20) | 15 (19) | 17 (22) | 17 (22) | 15 (19) |
| Device sized: | |||||
| - 22 gauge | 76 (48) | 37 (46) | 39 (49) | 35 (44) | 41 (51) |
| - 20 gauge | 67 (42) | 33 (41) | 34 (42) | 35 (44) | 32 (40) |
| Extension tubing | 82 (51) | 41 (51) | 41 (51) | 43 (54) | 39 (48) |
| 3-way tap | 118 (74) | 59 (74) | 59 (74) | 59 (75) | 59 (73) |
n (%) shown unless otherwise indicated post. posterior, ant. anterior, cub. cubital, mL millilitres, h hours, tx treatment, uupper, l lower
a Estimated
b Frequencies may not add up to group size due to missing/omitted values
c Versus all other
d Other categories omitted
Device outcomes at removal
| Outcome | Total ( | Flush volume | Flush frequency | ||
|---|---|---|---|---|---|
| 3 mL ( | 10 mL ( | 24 h ( | 6 h ( | ||
| Device failure: | 73 (46) | 29 (36) | 44 (55) | 32 (41) | 41 (51) |
| - occlusion or leaking | 22 (14) | 12 (15) | 10 (12) | 9 (11) | 13 (16) |
| - infiltration | 18 (11) | 4 (5) | 14 (18) | 10 (13) | 8 (10) |
| - phlebitis or too painful | 22 (14) | 7 (9) | 15 (19) | 8 (10) | 14 (17) |
| - dislodgment | 15 (9) | 5 (6) | 10 (12) | 7 (9) | 8 (10) |
| Device dwell time (days)a | 2.70 (1.66–4.02) | 2.23 (1.46–4.32) | 2.73 (1.71–3.98) | 2.83 (1.65–4.25) | 2.26 (1.67–3.58) |
| Device-hours | 11,911 | 5,998 | 5,914 | 6,327 | 5,584 |
| Incidence rate (95 % CI)b | 6.13 (4.87–7.71) | 4.84 (3.36–6.96) | 7.44 (5.54–10.0) | 5.06 (3.58–7.15) | 7.34 (5.41–9.97) |
| Log-rank test ( | - | 0.063 | 0.054 | ||
n (%) shown unless otherwise noted
CI confidence interval
a Median and inter-quartile range
b Per 1000 device-hours
Fig. 2Kaplan-Meier survival from PIVC failure (n = 160) by a flushing volume (p = 0.063, log-rank) and b flushing frequency (p = 0.054, log-rank)
Cox proportional hazards regression (n = 160)
| Univariable | Multivariable | |
|---|---|---|
| HR (95 % CI) | HR (95 % CI) | |
| 10 mL volume (referent: 3 mL) | 1.56 (0.97–2.50)* | f |
| 6 hr frequency (referent = 24 h) | 1.58 (0.99–2.53)* | f |
| Interaction of volume and frequencya | 0.54 (0.21–1.42) | f |
| Age (one year increase) | 1.00 (0.99,1.02) | f |
| Gender (female) | 1.90 (1.18,3.05)*** | 2.17 (1.33,3.55)*** |
| Weight (over/obese) | 1.29 (0.81,2.05) | f |
| Comorbidities (one category higher)b | 1.03 (0.78,1.35) | f |
| Insertion on dominant side | 1.67 (1.01,2.76)** | f |
| Infection at baseline (any) | 1.56 (0.93,2.59)* | f |
| Antibiotics at baseline (yes) | 0.99 (0.60,1.64) | f |
| IV treatment at baseline (yes) | 0.95 (0.43,2.07) | f |
| Insertion at hand/posterior wristc | 1.67 (1.04,2.70)** | 1.66 (1.02,2.69)** |
| Insertion at forearma | 0.58 (0.35,0.97)** | e |
| Insertion at cub. fossa/ant. upper armc | 1.01 (0.53,1.93) | f |
| Inserted by IV servicec | 0.95 (0.59,1.52) | f |
| Inserted by nursec | 2.01 (1.11,3.63)** | f |
| Size (20 g versus 22 g) | 1.14 (0.70,1.87) | f |
| Vein quality (poor) | 1.26 (0.79,2.01) | f |
| Multiple insertion attempts (yes) | 1.32 (0.78,2.23) | f |
| Extension tubing (yes) | 1.25 (0.78,1.98) | f |
| 3-way tap (yes) | 1.33 (0.79,2.24) | f |
| IV treatment at device removal (yes) | 2.61 (1.28,5.29)*** | e |
| IV treatment rate at device removald | 1.40 (1.07,1.82)** | e |
| IV antibiotics at device removal (yes) | 2.07 (1.27,3.38)*** | e |
| IV antibiotics rate at device removald | 1.33 (1.09,1.62)*** | e |
| Medication types administered: | ||
| - antibioticsc | 1.12 (0.67,1.87) | f |
| - cephalosporinsc | 0.80 (0.49,1.32) | f |
| - penicillin combinationc | 0.75 (0.40,1.41) | f |
| Episode rate (medications and flushes) | 1.22 (1.08,1.38)*** | 1.25 (1.10,1.41)*** |
HR hazard ratio, CI confidence interval, IV intravenous
*p value <0.2; **p value <0.05; ***p value <0.01
aModel for the interaction term results included the main effects
bOrdinal: 0 = none/one, 1 = two/three, 2 = four or more
cVersus all others
dPer day, ordinal: 0 = none, 1 = one/two, 2 = three/four, 3 = five or more
eExcluded due to correlation with other covariate
fCovariate not entered into multivariate model (at p ≥ 0.2), or removed during model building at p > 0.05. Only variables p < 0.2 on univariable analysis entered into the multivariable model