STUDY
DESIGN: Prospective clinical trial of the screw insertion method for posterior C1-C2 fixation utilizing the patient-specific screw guide template technique.
OBJECTIVE: To evaluate the efficacy of this method for insertion of C1 lateral mass screws (LMS), C2 pedicle screws (PS), and C2 laminar screws (LS). SUMMARY OF BACKGROUND DATA: Posterior C1LMS and C2PS fixation, also known as the Goel-Harms method, can achieve immediate rigid fixation and high fusion rate, but the screw insertion carries the risk of injury to neuronal and vascular structures. Dissection of venous plexus and C2 nerve root to confirm the insertion point of the C1LMS may also cause problems. We have developed an intraoperative screw guiding method using patient-specific laminar templates.
METHODS: Preoperative bone images of computed tomography (CT) were analyzed using three-dimensional (3D)/multiplanar imaging software to plan the trajectories of the screws. Plastic templates with screw guiding structures were created for each lamina using 3D design and printing technology. Three types of templates were made for precise multistep guidance, and all templates were specially designed to fit and lock on the lamina during the procedure. Surgery was performed using this patient-specific screw guide template system, and placement of the screws was postoperatively evaluated using CT.
RESULTS: Twelve patients with C1-C2 instability were treated with a total of 48 screws (24 C1LMS, 20 C2PS, 4 C2LS). Intraoperatively, each template was found to exactly fit and lock on the lamina and screw insertion was completed successfully without dissection of the venous plexus and C2 nerve root. Postoperative CT showed no cortical violation by the screws, and mean deviation of the screws from the planned trajectories was 0.70 ± 0.42 mm.
CONCLUSION: The multistep, patient-specific screw guide template system is useful for intraoperative screw navigation in posterior C1-C2 fixation. This simple and economical method can improve the accuracy of screw insertion, and reduce operation time and radiation exposure of posterior C1-C2 fixation surgery. LEVEL OF EVIDENCE: 3.

Entities:  

Mesh:

Year:  2017        PMID: 27454537     DOI: 10.1097/BRS.0000000000001807

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  16 in total

Review 1.  Systematic review of 3D printing in spinal surgery: the current state of play.

Authors:  Ben Wilcox; Ralph J Mobbs; Ai-Min Wu; Kevin Phan
Journal:  J Spine Surg       Date:  2017-09

Review 2.  Image once, print thrice? Three-dimensional printing of replacement parts.

Authors:  Timothy M Rankin; Blair A Wormer; John D Miller; Nicholas A Giovinco; Salam Al Kassis; David G Armstrong
Journal:  Br J Radiol       Date:  2018-01-31       Impact factor: 3.039

Review 3.  3D printing in spine surgery.

Authors:  Evan D Sheha; Sapan D Gandhi; Matthew W Colman
Journal:  Ann Transl Med       Date:  2019-09

4.  Design, Fabrication, and Accuracy of a Novel Noncovering Lock-Mechanism Bilateral Patient-Specific Drill Guide Template for Nondeformed and Deformed Thoracic Spines.

Authors:  Mehran Ashouri-Sanjani; Shima Mohammadi-Moghadam; Parisa Azimi; Navid Arjmand
Journal:  HSS J       Date:  2021-03-04

Review 5.  3D-printed navigation template in cervical spine fusion: a systematic review and meta-analysis.

Authors:  Parisa Azimi; Taravat Yazdanian; Edward C Benzel; Ali Azimi; Ali Montazeri
Journal:  Eur Spine J       Date:  2020-09-16       Impact factor: 3.134

6.  Accuracy Assessment of Using Rapid Prototyping Drill Templates for Atlantoaxial Screw Placement: A Cadaver Study.

Authors:  Shuai Guo; Teng Lu; Qiaolong Hu; Baohui Yang; Xijing He; Haopeng Li
Journal:  Biomed Res Int       Date:  2016-11-28       Impact factor: 3.411

Review 7.  A Review of Current Clinical Applications of Three-Dimensional Printing in Spine Surgery.

Authors:  Woojin Cho; Alan Varkey Job; Jing Chen; Jung Hwan Baek
Journal:  Asian Spine J       Date:  2018-02-07

8.  A 3D navigation template for guiding a unilateral lumbar pedicle screw with contralateral translaminar facet screw fixation: a study protocol for multicentre randomised controlled trials.

Authors:  Zhen-Xuan Shao; Wei He; Shao-Qi He; Sheng-Lei Lin; Zhe-Yu Huang; Hong-Chao Tang; Wen-Fei Ni; Xiang-Yang Wang; Ai-Min Wu
Journal:  BMJ Open       Date:  2017-07-21       Impact factor: 2.692

9.  A 3-Dimensional-Printed Spine Localizer: Introducing the Concept of Online Dissemination of Novel Surgical Instruments.

Authors:  Peyman Pakzaban
Journal:  Neurospine       Date:  2018-08-22

10.  Accuracy and safety of C2 pedicle or pars screw placement: a systematic review and meta-analysis.

Authors:  Parisa Azimi; Taravat Yazdanian; Edward C Benzel; Hossein Nayeb Aghaei; Shirzad Azhari; Sohrab Sadeghi; Ali Montazeri
Journal:  J Orthop Surg Res       Date:  2020-07-20       Impact factor: 2.359

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.