Literature DB >> 27451261

Ultra-low-dose chest CT with iterative reconstruction does not alter anatomical image quality.

F Macri1, J Greffier2, F R Pereira2, C Mandoul2, E Khasanova2, G Gualdi3, J P Beregi2.   

Abstract

PURPOSE: To evaluate the effect of dose reduction with iterative reconstruction (IR) on image quality of chest CT scan.
MATERIALS AND METHODS: Eighteen human cadavers had chest CT with one reference CT protocol (RP-CT; 120kVp/200mAs) and two protocols with dose reduction: low-dose-CT (LD-CT; 120kVp/40mAs) and ultra-low-dose CT (ULD-CT; 120kVp/10mAs). Data were reconstructed with filter-back-projection (FBP) for RP-CT and with FBP and IR (sinogram affirmed iterative reconstruction [SAFIRE®]) algorithm for LD-CT and ULD-CT. Volume CT dose index (CTDIvol) were recorded. The signal-to-noise (SNR), contrast-to-noise (CNR) ratios of LD-CT and ULD-CT and quantitative parameters were compared to RP-CT. Two radiologists reviewed the CT examinations assessed independently the quality of anatomical structures and expressed a confidence level using a 2-point scale (50% and 95%).
RESULTS: CTDIvol was 2.69 mGy for LD-CT (-80%; P<0.01) and 0.67 mGy for ULD-CT (-95%; P<0.01) as compared to 13.42 mGy for RP-CT. SNR and CNR were significantly decreased (P<0.01) for LD-CT and ULD-CT, but IR improved these values satisfactorily. No significant differences were observed for quantitative measurements. Radiologists rated excellent/good the RP-CT and LD-CT images, whereas good/fair the ULD-CT images. Confidence level for subjective anatomical analysis was 95% for all protocols.
CONCLUSIONS: Dose reduction with a dose lower than 1 mGy, used in conjunction with IR allows performing chest CT examinations that provide a high quality of anatomical structures.
Copyright © 2016 Editions françaises de radiologie. Published by Elsevier Masson SAS. All rights reserved.

Entities:  

Keywords:  Dose reduction; Image quality; Safire(®); Sinogram affirmed iterative reconstruction; Ultra-low-dose chest CT

Mesh:

Year:  2016        PMID: 27451261     DOI: 10.1016/j.diii.2016.06.009

Source DB:  PubMed          Journal:  Diagn Interv Imaging        ISSN: 2211-5684            Impact factor:   4.026


  4 in total

1.  Iterative reconstruction improves image quality and reduces radiation dose in trauma protocols; A human cadaver study.

Authors:  Johannes Clemens Godt; Cathrine K Johansen; Anne Catrine T Martinsen; Anselm Schulz; Helga M Brøgger; Kristin Jensen; Arne Stray-Pedersen; Johann Baptist Dormagen
Journal:  Acta Radiol Open       Date:  2021-11-18

2.  Image Quality and Pulmonary Nodule Detectability at Low-dose Computed Tomography (low kVp and mAs): A phantom study.

Authors:  Sepideh Iranmakani; Amir Reza Jahanshahi; Parinaz Mehnati; Tohid Mortezazadeh; Davood Khezerloo
Journal:  J Med Signals Sens       Date:  2021-12-28

3.  Early results of ultra-low-dose CT-scan for extremity traumas in emergency room.

Authors:  Taki Eddine Addala; Joël Greffier; Aymeric Hamard; Fehmi Snene; Xavier Bobbia; Sophie Bastide; Asmaa Belaouni; Hélène de Forges; Ahmed Larbi; Jean-Emmanuel de la Coussaye; Jean-Paul Beregi; Pierre-Géraud Claret; Julien Frandon
Journal:  Quant Imaging Med Surg       Date:  2022-08

4.  Proposal of a low-dose, long-pitch, dual-source chest CT protocol on third-generation dual-source CT using a tin filter for spectral shaping at 100 kVp for CoronaVirus Disease 2019 (COVID-19) patients: a feasibility study.

Authors:  Andrea Agostini; Chiara Floridi; Alessandra Borgheresi; Myriam Badaloni; Paolo Esposto Pirani; Filippo Terilli; Letizia Ottaviani; Andrea Giovagnoni
Journal:  Radiol Med       Date:  2020-04-01       Impact factor: 6.313

  4 in total