Literature DB >> 27451057

Stair ascent and descent biomechanical adaptations while using a custom ankle-foot orthosis.

Jennifer M Aldridge Whitehead1, Elizabeth Russell Esposito2, Jason M Wilken1.   

Abstract

The ability to navigate stairs step-over-step is an important functional outcome following severe lower leg injury and is difficult for many patients. Ankle-foot orthoses, such as the Intrepid Dynamic Exoskeletal Orthosis (IDEO), are often prescribed to improve function. This study compared stair climbing mechanics between IDEO users and able-bodied control participants. Thirteen IDEO users who sustained severe lower leg injury and 13 controls underwent biomechanical gait analysis. Participants ascended and descended a 16-step instrumented staircase without handrail use at a controlled cadence of 80 steps/min. Peak joint angles, moments, powers, and ground reaction forces, and integrated mechanical work were calculated. Independent t-tests with Bonferroni-Holm corrections were used to compare controls to IDEO and sound limbs. Reduced ankle range of motion on the IDEO limb resulted in compensatory strategies while ascending or descending stairs. During ascent, IDEO users had greater bilateral hip power during pull-up (p<0.007) to compensate for the IDEO limb׳s reduced ankle dorsiflexion (p<0.001) and knee extensor moment (p=0.001) while it was leading, and reduced ankle plantarflexor power while it was trailing (p<0.001). During stair descent, when the IDEO limb had was trailing, it had less ankle dorsiflexion during controlled lowering (p<0.001), resulting in greater vertical ground reaction force (p=0.005) and greater ankle and knee power absorption (p<0.001). Reduced IDEO limb ankle power absorption during weight acceptance (p<0.001) resulted in a large knee extensor moment (p<0.001) on the trailing sound limb to lower the body. Despite gait deviations, IDEO users were able to climb stairs step-over-step unassisted. Published by Elsevier Ltd.

Entities:  

Keywords:  IDEO; Kinematics; Kinetics; Limb preservation; Limb salvage; Military

Mesh:

Year:  2016        PMID: 27451057     DOI: 10.1016/j.jbiomech.2016.06.035

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  1 in total

Review 1.  Design principles, manufacturing and evaluation techniques of custom dynamic ankle-foot orthoses: a review study.

Authors:  Giulia Rogati; Paolo Caravaggi; Alberto Leardini
Journal:  J Foot Ankle Res       Date:  2022-05-19       Impact factor: 3.050

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.