Literature DB >> 27447789

Three-dimensional assessment of postural tremor during goal-directed aiming.

K J Kelleran1, S Morrison2, D M Russell2.   

Abstract

The performance of fine motor tasks which require a degree of precision can be negatively affected by physiological tremor. This study examined the effect of different aiming positions on anterior-posterior (AP), medial-lateral (ML) and vertical (VT) postural tremor. Participants were required to aim a mock handgun at a target located in front of them at eye level. Changes in AP, ML and VT tremor from the forearm and gun barrel were assessed as a function of limb (i.e., whether one or both arms were used) and upper arm position (elbow bent or extended). Tremor was recorded using triaxial accelerometers. Results showed that, across all tasks, the ML and VT tremor for any point was characterized by two frequency peaks (between 1-4 and 8-12 Hz) with amplitude increasing from proximal (forearm) to distal (gun barrel). Interestingly, irrespective of the posture adopted, ML accelerations were of greater amplitude than VT oscillations. AP oscillations were markedly smaller compared to VT and ML tremor, did not display consistent frequency peaks, and were not altered by the arm conditions. Altering the aiming posture resulted in changes in VT and ML tremor amplitude, with oscillations being greater when using a single arm as compared to when two arms were used together. Similarly, tremor amplitude was reduced when the task was performed with the elbow bent compared to the straight arm condition. Overall, these results highlight that ML oscillations make as significant a contribution to the overall tremor dynamics as those observed in the VT direction. However, the origin of ML tremor is not simply the product of voluntary adjustments to maintain aim on the target, but also exhibits features similar to the neural generated 8-12-Hz tremor seen under postural conditions.

Entities:  

Keywords:  Accelerometry; Handgun; Motor control; Pistol; Pointing; Shooting

Mesh:

Year:  2016        PMID: 27447789     DOI: 10.1007/s00221-016-4738-x

Source DB:  PubMed          Journal:  Exp Brain Res        ISSN: 0014-4819            Impact factor:   1.972


  55 in total

1.  Temporal and force characteristics of fast double-finger, single-finger and hand tapping.

Authors:  T Aoki; H Kinoshita
Journal:  Ergonomics       Date:  2001-12-15       Impact factor: 2.778

2.  Postural consistency in skilled archers.

Authors:  J Stuart; J Atha
Journal:  J Sports Sci       Date:  1990       Impact factor: 3.337

3.  Augmented visual feedback increases finger tremor during postural pointing.

Authors:  J Keogh; S Morrison; R Barrett
Journal:  Exp Brain Res       Date:  2004-07-30       Impact factor: 1.972

4.  Postural fluctuations during pointing from a unilateral or bilateral stance.

Authors:  Ing-Shiou Hwang; Chien-Ting Huang; Rong-Ju Cherng; Chien-Chun Huang
Journal:  Hum Mov Sci       Date:  2006-02-03       Impact factor: 2.161

5.  Motor-unit activity responsible for 8- to 12-Hz component of human physiological finger tremor.

Authors:  R J Elble; J E Randall
Journal:  J Neurophysiol       Date:  1976-03       Impact factor: 2.714

6.  Coding of pulsatile motor output by human muscle afferents during slow finger movements.

Authors:  J Wessberg; A B Vallbo
Journal:  J Physiol       Date:  1995-05-15       Impact factor: 5.182

7.  Mechanistic components of normal hand tremor.

Authors:  R J Elble; J E Randall
Journal:  Electroencephalogr Clin Neurophysiol       Date:  1978-01

8.  Mechanical and neural feedback factors in postural hand tremor of normal subjects.

Authors:  R N Stiles
Journal:  J Neurophysiol       Date:  1980-07       Impact factor: 2.714

9.  The effect of supporting a surgeon's wrist on their hand tremor.

Authors:  Chris J Coulson; Paul S Slack; Xianghong Ma
Journal:  Microsurgery       Date:  2010-10       Impact factor: 2.425

10.  Frequency and displacement amplitude relations for normal hand tremor.

Authors:  R N Stiles
Journal:  J Appl Physiol       Date:  1976-01       Impact factor: 3.531

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.