Literature DB >> 27446645

Continuously zoom imaging probe for the multi-resolution foveated laparoscope.

Yi Qin1, Hong Hua1.   

Abstract

In modern minimally invasive surgeries (MIS), standard laparoscopes suffer from the tradeoff between the spatial resolution and field of view (FOV). The inability of simultaneously acquiring high-resolution images for accurate operation and wide-angle overviews for situational awareness limits the efficiency and outcome of the MIS. A dual view multi-resolution foveated laparoscope (MRFL) which can simultaneously provide the surgeon with a high-resolution view as well as a wide-angle overview was proposed and demonstrated to have great potential for improving the MIS. Although experiment results demonstrated the high-magnification probe has an adequate magnification for viewing surgical details, the dual-view MRFL is limited to two fixed levels of magnifications. A fine adjustment of the magnification is highly desired for obtaining high resolution images with desired field coverage. In this paper, a high magnification probe with continuous zooming capability without any mechanical moving parts is demonstrated. By taking the advantages of two electrically tunable lenses, one for optical zoom and the other for image focus compensation, the optical magnification of the high-magnification probe varies from 2 × to 3 × compared with that of the wide-angle probe, while the focused object position stays the same as the wide-angle probe. The optical design and the tunable lens analysis are presented, followed by prototype demonstration.

Keywords:  (120.3890) Medical optics instrumentation; (170.0110) Imaging systems; (170.2150) Endoscopic imaging; (170.3880) Medical and biological imaging; (170.4580) Optical diagnostics for medicine; (220.0220) Optical design and fabrication

Year:  2016        PMID: 27446645      PMCID: PMC4929630          DOI: 10.1364/BOE.7.001175

Source DB:  PubMed          Journal:  Biomed Opt Express        ISSN: 2156-7085            Impact factor:   3.732


  9 in total

Review 1.  Complications and recommended practices for electrosurgery in laparoscopy.

Authors:  M P Wu; C S Ou; S L Chen; E Y Yen; R Rowbotham
Journal:  Am J Surg       Date:  2000-01       Impact factor: 2.565

2.  Fluidic lens laparoscopic zoom camera for minimally invasive surgery.

Authors:  Frank S Tsai; Daniel Johnson; Cameron S Francis; Sung Hwan Cho; Wen Qiao; Ashkan Arianpour; Yoav Mintz; Santiago Horgan; Mark Talamini; Yu-Hwa Lo
Journal:  J Biomed Opt       Date:  2010 May-Jun       Impact factor: 3.170

3.  Advantages of advanced laparoscopic systems.

Authors:  J Heemskerk; R Zandbergen; J G Maessen; J W M Greve; N D Bouvy
Journal:  Surg Endosc       Date:  2006-03-09       Impact factor: 4.584

4.  Enhanced vision system for laparoscopic surgery.

Authors:  Brahim Tamadazte; Gaelle Fiard; Jean-Alexandre Long; Philippe Cinquin; Sandrine Voros
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2013

5.  Zoom lens design using liquid lens for laparoscope.

Authors:  Seungwan Lee; Minseog Choi; Eunsung Lee; Kyu-Dong Jung; Jong-Hyeon Chang; Woonbae Kim
Journal:  Opt Express       Date:  2013-01-28       Impact factor: 3.894

6.  Laparoscopic versus open radical prostatectomy: a comparative study at a single institution.

Authors:  Jens Rassweiler; Othmar Seemann; Michael Schulze; Dogu Teber; Martin Hatzinger; Thomas Frede
Journal:  J Urol       Date:  2003-05       Impact factor: 7.450

7.  Multiresolution foveated laparoscope with high resolvability.

Authors:  Yi Qin; Hong Hua; Mike Nguyen
Journal:  Opt Lett       Date:  2013-07-01       Impact factor: 3.776

8.  Characterization and in-vivo evaluation of a multi-resolution foveated laparoscope for minimally invasive surgery.

Authors:  Yi Qin; Hong Hua; Mike Nguyen
Journal:  Biomed Opt Express       Date:  2014-07-10       Impact factor: 3.732

9.  Optical design and evaluation of a 4 mm cost-effective ultra-high-definition arthroscope.

Authors:  Dewen Cheng; Yongtian Wang; Lu Yu; Xiaohua Liu
Journal:  Biomed Opt Express       Date:  2014-07-18       Impact factor: 3.732

  9 in total
  7 in total

1.  Prism-based tri-aperture laparoscopic objective for multi-view acquisition.

Authors:  Elliott Kwan; Hong Hua
Journal:  Opt Express       Date:  2022-01-17       Impact factor: 3.894

2.  High-throughput multi-resolution foveated laparoscope for minimally invasive surgery.

Authors:  Jeremy I Katz; Hong Hua
Journal:  Biomed Opt Express       Date:  2022-05-12       Impact factor: 3.562

3.  Pre-Clinical Translation of Second Harmonic Microscopy of Meniscal and Articular Cartilage Using a Prototype Nonlinear Microendoscope.

Authors:  Stephen J Baskey; Marco Andreana; Eric Lanteigne; Andrew Ridsdale; Albert Stolow; Mark E Schweitzer
Journal:  IEEE J Transl Eng Health Med       Date:  2018-12-25       Impact factor: 3.316

4.  Improved multi-resolution foveated laparoscope with real-time digital transverse chromatic correction.

Authors:  Jeremy I Katz; Sang-Yoon Lee; Hong Hua
Journal:  Appl Opt       Date:  2020-08-01       Impact factor: 1.980

5.  Electrically tunable fluidic lens imaging system for laparoscopic fluorescence-guided surgery.

Authors:  Davide Volpi; Iain D C Tullis; Paul R Barber; Edyta M Augustyniak; Sean C Smart; Katherine A Vallis; Borivoj Vojnovic
Journal:  Biomed Opt Express       Date:  2017-06-13       Impact factor: 3.562

6.  Speeded-Up Focus Control of Electrically Tunable Lens by Sparse Optimization.

Authors:  Daisuke Iwai; Hidetoshi Izawa; Kenji Kashima; Tatsuyuki Ueda; Kosuke Sato
Journal:  Sci Rep       Date:  2019-08-26       Impact factor: 4.379

7.  A Hybrid Bionic Image Sensor Achieving FOV Extension and Foveated Imaging.

Authors:  Qun Hao; Zihan Wang; Jie Cao; Fanghua Zhang
Journal:  Sensors (Basel)       Date:  2018-03-30       Impact factor: 3.576

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.