A critical assessment of the performance criteria in confirmatory analysis for veterinary drug residue analysis using mass spectrometric detection in selected reaction monitoring mode.

Bjorn J A Berendsen1, Thijs Meijer1, Robin Wegh1, Hans G J Mol1, Wesley G Smyth2, S Armstrong Hewitt2, Leen van Ginkel1, Michel W F Nielen1,3.   

Abstract

Besides the identification point system to assure adequate set-up of instrumentation, European Commission Decision 2002/657/EC includes performance criteria regarding relative ion abundances in mass spectrometry and chromatographic retention time. In confirmatory analysis, the relative abundance of two product ions, acquired in selected reaction monitoring mode, the ion ratio should be within certain ranges for confirmation of the identity of a substance. The acceptable tolerance of the ion ratio varies with the relative abundance of the two product ions and for retention time, CD 2002/657/EC allows a tolerance of 5%. Because of rapid technical advances in analytical instruments and new approaches applied in the field of contaminant testing in food products (multi-compound and multi-class methods) a critical assessment of these criteria is justified. In this study a large number of representative, though challenging sample extracts were prepared, including muscle, urine, milk and liver, spiked with 100 registered and banned veterinary drugs at levels ranging from 0.5 to 100 µg/kg. These extracts were analysed using SRM mode using different chromatographic conditions and mass spectrometers from different vendors. In the initial study, robust data was collected using four different instrumental set-ups. Based on a unique and highly relevant data set, consisting of over 39 000 data points, the ion ratio and retention time criteria for applicability in confirmatory analysis were assessed. The outcomes were verified based on a collaborative trial including laboratories from all over the world. It was concluded that the ion ratio deviation is not related to the value of the ion ratio, but rather to the intensity of the lowest product ion. Therefore a fixed ion ratio deviation tolerance of 50% (relative) is proposed, which also is applicable for compounds present at sub-ppb levels or having poor ionisation efficiency. Furthermore, it was observed that retention time shifts, when using gradient elution, as is common practice nowadays, are mainly observed for early eluting compounds. Therefore a maximum retention time deviation of 0.2 min (absolute) is proposed. These findings should serve as input for discussions on the revision of currently applied criteria and the establishment of a new, globally accepted, criterion document for confirmatory analysis.
Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.

Entities:  

Keywords:  confirmatory analysis; ion ratio; liquid chromatography; mass spectrometry; performance criteria

Mesh:

Substances:

Year:  2016        PMID: 27443202     DOI: 10.1002/dta.2021

Source DB:  PubMed          Journal:  Drug Test Anal        ISSN: 1942-7603            Impact factor:   3.345


  3 in total

1.  Co-Occurrence of Regulated, Masked and Emerging Mycotoxins and Secondary Metabolites in Finished Feed and Maize-An Extensive Survey.

Authors:  Paula Kovalsky; Gregor Kos; Karin Nährer; Christina Schwab; Timothy Jenkins; Gerd Schatzmayr; Michael Sulyok; Rudolf Krska
Journal:  Toxins (Basel)       Date:  2016-12-06       Impact factor: 4.546

2.  The analysis of tetracyclines, quinolones, macrolides, lincosamides, pleuromutilins, and sulfonamides in chicken feathers using UHPLC-MS/MS in order to monitor antibiotic use in the poultry sector.

Authors:  Larissa J M Jansen; Yvette J C Bolck; Janneau Rademaker; Tina Zuidema; Bjorn J A Berendsen
Journal:  Anal Bioanal Chem       Date:  2017-07-04       Impact factor: 4.142

3.  Establishing Analytical Performance Criteria for the Global Reconnaissance of Antibiotics and Other Pharmaceutical Residues in the Aquatic Environment Using Liquid Chromatography-Tandem Mass Spectrometry.

Authors:  Luisa F Angeles; Diana S Aga
Journal:  J Anal Methods Chem       Date:  2018-06-04       Impact factor: 2.193

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.