Literature DB >> 27438720

Lateral flow biosensor for multiplex detection of nitrofuran metabolites based on functionalized magnetic beads.

Xuewen Lu1, Xiaoling Liang1,2, Jianghong Dong1, Zhiyuan Fang3, Lingwen Zeng4,5.   

Abstract

The use of potential mutagenic nitrofuran antibiotic in food animal production has been banned world-wide. Common methods for nitrofuran detection involve complex extraction procedures. In the present study, magnetic beads functionalized with antibody against nitrofuran derivative were used as both the extraction and color developing media in lateral flow biosensor. Derivatization reagent carboxybenzaldehyde is firstly modified with ractopamine. After reaction with nitrofuran metabolites, the resultant molecule has two functional groups: the metabolite moiety and the ractopamine moiety. Metabolite moiety is captured by the antibody that is coated on magnetic beads. This duplex is then loaded onto biosensor and ractopamine moiety is further captured by the antibody immobilized on the test zone of nitrocellulose membrane. Without tedious organic reagent-based extraction procedure, this biosensor was capable of visually detecting four metabolites simultaneously with a detection limit of 0.1 μg/L. No cross-reactivity was observed in the presence of 50 μg/L interferential components. Graphical abstract Derivatization of nitrofuran metabolites (AHD, AOZ, SEM, or AMOZ) and LFA detection of the derivative products.

Entities:  

Keywords:  Fast pre-treatment; Lateral flow biosensor; Magnetic separation; Nitrofuran metabolites

Mesh:

Substances:

Year:  2016        PMID: 27438720     DOI: 10.1007/s00216-016-9787-2

Source DB:  PubMed          Journal:  Anal Bioanal Chem        ISSN: 1618-2642            Impact factor:   4.142


  4 in total

Review 1.  Lateral flow biosensors based on the use of micro- and nanomaterials: a review on recent developments.

Authors:  Yan Huang; Tailin Xu; Wenqian Wang; Yongqiang Wen; Kun Li; Lisheng Qian; Xueji Zhang; Guodong Liu
Journal:  Mikrochim Acta       Date:  2019-12-18       Impact factor: 5.833

2.  Magnetized carbon nanotubes for visual detection of proteins directly in whole blood.

Authors:  Yan Huang; Yongqiang Wen; Kwaku Baryeh; Sunitha Takalkar; Michelle Lund; Xueji Zhang; Guodong Liu
Journal:  Anal Chim Acta       Date:  2017-09-27       Impact factor: 6.558

Review 3.  Recent advances in sensitivity enhancement for lateral flow assay.

Authors:  Yulin Deng; Hao Jiang; Xiaoqiong Li; Xuefei Lv
Journal:  Mikrochim Acta       Date:  2021-10-13       Impact factor: 5.833

4.  Ultrasensitive strips for the quadruple detection of nitrofuran metabolite residues.

Authors:  Wei Wu; Ning Sun; Simin Zhu; Xiaomei Li; Jitao Chen; Chunzhao Liu; Zhiyuan Fang; Qingli Yang
Journal:  RSC Adv       Date:  2019-01-21       Impact factor: 4.036

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.