PURPOSE: Allografts are frequently used for anterior cruciate ligament (ACL) reconstruction. However, due to the inherent risk of infection, a method that achieves complete sterilization of grafts is warranted without impairing their biomechanical properties. Fractionation of electron beam (FEbeam) irradiation has been shown to maintain similar biomechanical properties compared to fresh-frozen allografts (FFA) in vitro. Therefore, aim of this study was to evaluate the biomechanical properties and early remodelling of grafts that were sterilized with fractionated high-dose electron beam irradiation in an in vivo sheep model.
METHODS: ACL reconstruction was performed in 18 mature merino mix sheep. Sixteen were reconstructed with allografts sterilized with FEbeam irradiation (8 × 3.4 kGy) and two with FFA. Eight FFA from prior studies with identical surgical reconstruction and biomechanical and histological analyzes served as controls. Half of the animals were sacrificed at 6 and 12 weeks, and biomechanical testing was performed. Anterior-posterior laxity (APL) was assessed with an AP drawer test at 60° flexion, and load to failure testing was carried out. Histological evaluation of mid-substance samples was performed for descriptive analysis, cell count, crimp and vessel density. For statistical analysis a Kruskal-Wallis test was used for overall group comparison followed by a Mann-Whitney U test for pairwise comparison of the histological and biomechanical parameters.
RESULTS: Biomechanical testing showed significantly decreased stiffness in FEbeam compared to FFA at both time points (p ≤ 0.004). APL was increased in FEbeam compared to FFA, which was significant at 6 weeks (p = 0.004). Median of failure loads was decreased in FEbeam grafts, with 12 reconstructions already failing during cyclic loading. Vessel density was decreased in FEbeam compared to FFA at both time points, with significant differences at 12 weeks (p = 0.015). Crimp length was significantly shorter in FEbeam compared to FFA at both time points (p ≤ 0.004) and decreased significantly in both groups from 6 to 12 weeks (p ≤ 0.025).
CONCLUSION: ACL reconstruction with fractionated Ebeam sterilization significantly alters the biomechanical properties and the early remodelling process of treated grafts in vivo. Therefore, this sterilization method cannot be recommended for clinical application. As substantial changes in the remodelling are inherent in this study, care in the rehabilitation of even low-dose sterilized allografts, used for ACL reconstruction, is recommended.

Entities:  

Keywords:  ACL reconstruction; Allograft; Ebeam; Fractionation; Sterilization

Mesh:

Year:  2016        PMID: 27438006     DOI: 10.1007/s00167-016-4240-9

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  36 in total

Review 1.  Autograft Versus Allograft in Anterior Cruciate Ligament Reconstruction: A Meta-analysis of Randomized Controlled Trials and Systematic Review of Overlapping Systematic Reviews.

Authors:  Chao Zeng; Shu-guang Gao; Hui Li; Tuo Yang; Wei Luo; Yu-sheng Li; Guang-hua Lei
Journal:  Arthroscopy       Date:  2015-10-21       Impact factor: 4.772

2.  Cell survival following bone-anterior cruciate ligament-bone allograft transplantation: DNA fingerprints, segregation, and collagen morphological analysis of multiple markers in the canine model.

Authors:  M J Goertzen; J Buitkamp; H Clahsen; M Möllmann
Journal:  Arch Orthop Trauma Surg       Date:  1998       Impact factor: 3.067

3.  Revision Risk After Allograft Anterior Cruciate Ligament Reconstruction: Association With Graft Processing Techniques, Patient Characteristics, and Graft Type.

Authors:  Samir G Tejwani; Jason Chen; Tadashi T Funahashi; Rebecca Love; Gregory B Maletis
Journal:  Am J Sports Med       Date:  2015-06-11       Impact factor: 6.202

4.  High-dose electron beam sterilization of soft-tissue grafts maintains significantly improved biomechanical properties compared to standard gamma treatment.

Authors:  A Hoburg; S Keshlaf; T Schmidt; M Smith; U Gohs; C Perka; A Pruss; S Scheffler
Journal:  Cell Tissue Bank       Date:  2014-07-19       Impact factor: 1.522

Review 5.  Analysis of irradiation on the clinical effectiveness of allogenic tissue when used for primary anterior cruciate ligament reconstruction.

Authors:  Sam Si-Hyeong Park; Tim Dwyer; Francesco Congiusta; Daniel B Whelan; John Theodoropoulos
Journal:  Am J Sports Med       Date:  2014-01-29       Impact factor: 6.202

6.  The natural history of the anterior cruciate ligament autograft of patellar tendon origin.

Authors:  D Amiel; J B Kleiner; W H Akeson
Journal:  Am J Sports Med       Date:  1986 Nov-Dec       Impact factor: 6.202

7.  Effects of gamma irradiation on the human immunodeficiency virus. A study in frozen human bone-patellar ligament-bone grafts obtained from infected cadavera.

Authors:  B M Fideler; C T Vangsness; T Moore; Z Li; S Rasheed
Journal:  J Bone Joint Surg Am       Date:  1994-07       Impact factor: 5.284

8.  Effect of gamma irradiation on human cortical bone transplants contaminated with enveloped and non-enveloped viruses.

Authors:  Axel Pruss; Moujahed Kao; Uwe Gohs; Jürgen Koscielny; Rüdiger von Versen; Georg Pauli
Journal:  Biologicals       Date:  2002-06       Impact factor: 1.856

9.  [Influence of European regulations on quality, safety and availability of cell and tissue allografts in Germany].

Authors:  A Pruss; R von Versen
Journal:  Handchir Mikrochir Plast Chir       Date:  2007-04       Impact factor: 1.018

10.  Improved tendon radioprotection by combined cross-linking and free radical scavenging.

Authors:  Aaron Seto; Charles J Gatt; Michael G Dunn
Journal:  Clin Orthop Relat Res       Date:  2009-06-19       Impact factor: 4.176

View more
  4 in total

Review 1.  What Factors Influence the Biomechanical Properties of Allograft Tissue for ACL Reconstruction? A Systematic Review.

Authors:  Drew A Lansdown; Andrew J Riff; Molly Meadows; Adam B Yanke; Bernard R Bach
Journal:  Clin Orthop Relat Res       Date:  2017-10       Impact factor: 4.176

Review 2.  [Bone banks : The state-of-the-art].

Authors:  A Pruß; U Kalus
Journal:  Orthopade       Date:  2018-01       Impact factor: 1.087

3.  Unintended consequences of the potential phase-out of gamma irradiation.

Authors:  Jacquelyn W Chou; Michelle Skornicki; Joshua T Cohen
Journal:  F1000Res       Date:  2018-03-21

4.  Categorize the existing clamps used for tensile test of human graft- a systematic review.

Authors:  Denes Farago; Blanka Kozma; Rita Maria Kiss
Journal:  BMC Musculoskelet Disord       Date:  2022-07-25       Impact factor: 2.562

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.