Literature DB >> 27436773

Downscaling procedures reduce chemical use in androgen receptor reporter gene assay.

Carolina Di Paolo1, Kristina Kirchner2, Fabian Gerhard Peter Balk2, Matthias Muschket3, Werner Brack3, Henner Hollert4, Thomas-Benjamin Seiler2.   

Abstract

Bioactivity screening studies often face sample amount limitation with respect to the need for reliable, reproducible and quantitative results. Therefore approaches that minimize sample use are needed. Low-volume exposure and chemical dilution procedures were applied in an androgen receptor reporter gene human cell line assay to evaluate environmental contaminants and androgen receptor modulators, which were the agonist 5α-dihydrotestosterone (DHT); and the antagonists flutamide, bisphenol A, 1-hydroxypyrene and triclosan. Cells were exposed in around 1/3 of the medium volume recommended by the protocol (70μL/well). Further, chemical losses during pipetting steps were minimized by applying a low-volume method for compound dilution in medium (250μL for triplicate wells) inside microvolume glass inserts. Simultaneously, compounds were evaluated following conventional procedures (200μL/well, dilution in 24-well plates) for comparison of results. Low-volume exposure tests produced DHT EC50 (3.4-3.7×10(-10)M) and flutamide IC50 (2.2-3.3×10(-7)M) values very similar to those from regular assays (3.1-4.2×10(-10) and 2.1-3.3×10(-7)M respectively) and previous studies. Also, results were within assay acceptance criteria, supporting the relevance of the downscaling setup for agonistic and antagonistic tests. The low-volume exposure was also successful in determining IC50 values for 1-hydroxypyrene (2.1-2.8×10(-6)M), bisphenol A (2.6-3.3×10(-6)M), and triclosan (1.2-1.9×10(-6)M) in agreement with values obtained through high-volume exposure (2.3-2.8, 2.5-3.4 and 1.0-1.3×10(-6)M respectively). Finally, experiments following both low-volume dosing and exposure produced flutamide and triclosan IC50 values similar to those from regular tests. The low-volume experimental procedures provide a simple and effective solution for studies that need to minimize bioassay sample use while maintaining method reliability. The downscaling methods can be applied for the evaluation of samples, fractions or chemicals which require minimal losses during the steps of pipetting, transference to medium and exposure in bioassays.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  (Anti)androgens; Androgen receptor binders; Downscaling; Low-volume; Miniaturization; Reporter gene bioassay

Mesh:

Substances:

Year:  2016        PMID: 27436773     DOI: 10.1016/j.scitotenv.2016.07.059

Source DB:  PubMed          Journal:  Sci Total Environ        ISSN: 0048-9697            Impact factor:   7.963


  2 in total

1.  Triclocarban, Triclosan, Bromochlorophene, Chlorophene, and Climbazole Effects on Nuclear Receptors: An in Silico and in Vitro Study.

Authors:  Maša Kenda; Nataša Karas Kuželički; Mitsuru Iida; Hiroyuki Kojima; Marija Sollner Dolenc
Journal:  Environ Health Perspect       Date:  2020-10-16       Impact factor: 9.031

2.  Method Development for Effect-Directed Analysis of Endocrine Disrupting Compounds in Human Amniotic Fluid.

Authors:  Hanna M Dusza; Elwin Janssen; Rakesh Kanda; Juliette Legler
Journal:  Environ Sci Technol       Date:  2019-10-21       Impact factor: 9.028

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.