Literature DB >> 27433982

Integrated liquid chromatography method in enantioselective studies: Biodegradation of ofloxacin by an activated sludge consortium.

Alexandra S Maia1, Paula M L Castro2, Maria Elizabeth Tiritan3.   

Abstract

Ofloxacin is a chiral fluoroquinolone commercialized as racemate and as its enantiomerically pure form levofloxacin. This work presents an integrated liquid chromatography (LC) method with fluorescence detection (FD) and exact mass spectrometry (EMS) developed to assess the enantiomeric biodegradation of ofloxacin and levofloxacin in laboratory-scale microcosms. The optimized enantioseparation conditions were achieved using a macrocyclic antibiotic ristocetin A-bonded CSP (150×2.1mm i.d.; particle size 5μm) under reversed-phase elution mode. The method was validated using a mineral salts medium as matrix and presented selectivity and linearity over a concentration range from 5μgL(-1) (quantification limit) to 350μgL(-1) for each enantiomer. The method was successfully applied to evaluate biodegradation of ofloxacin enantiomers at 250μgL(-1) by an activated sludge inoculum. Ofloxacin (racemic mixture) and (S)-enantiomer (levofloxacin) were degraded up to 58 and 52%, respectively. An additional degradable carbon source, acetate, enhanced biodegradation up to 23%. (S)-enantiomer presented the highest extent of degradation (66.8%) when ofloxacin was supplied along with acetate. Results indicated slightly higher biodegradation extents for the (S)-enantiomer when supplementation was done with ofloxacin. Degradation occurred faster in the first 3days and proceeded slowly until the end of the assays. The chromatographic results from LC-FD suggested the formation of the (R)-enantiomer during levofloxacin biodegradation which was confirmed by LC-MS with a LTQ Orbitrap XL.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Activated sludge; Biodegradation; Enantioselectivity; Levofloxacin; Macrocyclic antibiotic-based stationary phases; Ofloxacin

Mesh:

Substances:

Year:  2016        PMID: 27433982     DOI: 10.1016/j.jchromb.2016.06.026

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  1 in total

Review 1.  Enantioselective Liquid Chromatographic Separations Using Macrocyclic Glycopeptide-Based Chiral Selectors.

Authors:  Róbert Berkecz; Dániel Tanács; Antal Péter; István Ilisz
Journal:  Molecules       Date:  2021-06-03       Impact factor: 4.411

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.