Literature DB >> 27433202

Anatomical relationship between the common carotid artery and the internal jugular vein during head rotation.

Izumi Miki1, Satoru Murata1, Ken Nakazawa1, Shiro Onozawa1, Takahiko Mine1, Tatsuo Ueda1, Hidenori Yamaguchi1, Daisuke Yasui1, Minako Takeda1, Shinichiro Kumita1.   

Abstract

This study investigated the anatomical relationship between the common carotid artery and internal jugular vein during head rotation for the effective performance of percutaneous transjugular procedures. The subjects included 30 volunteers who had never undergone internal jugular vein cannulation. In the supine position, two-dimensional ultrasonographic images of the right internal jugular vein and common carotid artery were obtained, 2 and 4 cm above the clavicle, along the lateral border of the sternal head of the sternocleidomastoid muscle. Ultrasonographic images were examined for head rotation at 0°, 15°, 30°, 45°, 60°, and 75° from the midline to the left. The percentage of overlap of the common carotid artery by the internal jugular vein and the flattening of the internal jugular vein at each head rotation position were measured and evaluated. The overlap of the common carotid artery by the internal jugular vein significantly increased at ≥45° of head rotation 2 cm above the clavicle (P < 0.01) and at ≥30° of head rotation 4 cm above the clavicle (P < 0.01), compared with that observed in the neutral position. The flattening of the internal jugular vein significantly decreased at ≥45° of head rotation 2 cm above the clavicle (P < 0.01) and at ≥30° of head rotation 4 cm above the clavicle (P < 0.01). Head rotation should be kept to <45° at 2 cm above the clavicle and <30° at 4 cm above the clavicle to decrease the risk of accidental puncture of the common carotid artery during internal jugular vein puncture. Moreover, flattening of the internal jugular vein gradually decreases during head rotation to the side.

Entities:  

Keywords:  Cannulation of the central veins; carotid artery; head rotation; internal jugular vein; vascular anatomy

Year:  2014        PMID: 27433202      PMCID: PMC4760536          DOI: 10.1177/1742271X14524571

Source DB:  PubMed          Journal:  Ultrasound        ISSN: 1742-271X


  9 in total

Review 1.  Preventing complications of central venous catheterization.

Authors:  David C McGee; Michael K Gould
Journal:  N Engl J Med       Date:  2003-03-20       Impact factor: 91.245

2.  Internal jugular vein and carotid artery anatomic relation as determined by ultrasonography.

Authors:  C A Troianos; R J Kuwik; J R Pasqual; A J Lim; D P Odasso
Journal:  Anesthesiology       Date:  1996-07       Impact factor: 7.892

3.  Head rotation during internal jugular vein cannulation and the risk of carotid artery puncture.

Authors:  C A Sulek; N Gravenstein; R H Blackshear; L Weiss
Journal:  Anesth Analg       Date:  1996-01       Impact factor: 5.108

4.  Anatomic relationship of the internal jugular vein and the common carotid artery applied to percutaneous transjugular procedures.

Authors:  Ulku C Turba; Renan Uflacker; Christopher Hannegan; J Bayne Selby
Journal:  Cardiovasc Intervent Radiol       Date:  2005 May-Jun       Impact factor: 2.740

5.  Is the internal jugular vein cannulated during insertion or withdrawal of the needle during central venous cannulation?

Authors:  D Mangar; W S Turnage; S A Mohamed
Journal:  Anesth Analg       Date:  1993-06       Impact factor: 5.108

6.  Complications and failures of subclavian-vein catheterization.

Authors:  P F Mansfield; D C Hohn; B D Fornage; M A Gregurich; D M Ota
Journal:  N Engl J Med       Date:  1994-12-29       Impact factor: 91.245

7.  Effect of head rotation on vascular anatomy of the neck: an ultrasound study.

Authors:  Ralph Wang; Eric R Snoey; Robert Carter Clements; H Gene Hern; Dan Price
Journal:  J Emerg Med       Date:  2006-10       Impact factor: 1.484

8.  Cross-sectional area of the right and left internal jugular veins.

Authors:  E B Lobato; C A Sulek; R L Moody; T E Morey
Journal:  J Cardiothorac Vasc Anesth       Date:  1999-04       Impact factor: 2.628

9.  Anatomical variations of internal jugular vein location: impact on central venous access.

Authors:  B G Denys; B F Uretsky
Journal:  Crit Care Med       Date:  1991-12       Impact factor: 7.598

  9 in total
  2 in total

1.  Anatomical relationship between the omohyoid muscle and the internal jugular vein on ultrasound guidance.

Authors:  Yun Yang; Xinqiang Wang; Weiliang Mao; Tongyun He; Zhaodong Xiong
Journal:  BMC Anesthesiol       Date:  2022-06-13       Impact factor: 2.376

Review 2.  Ultrasound-guided central venous catheter placement: a structured review and recommendations for clinical practice.

Authors:  Bernd Saugel; Thomas W L Scheeren; Jean-Louis Teboul
Journal:  Crit Care       Date:  2017-08-28       Impact factor: 9.097

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.