Literature DB >> 27430920

[A study of the diagnostic value of endobronchial ultrasound guide sheath transbronchial lung biopsy combined with virtual bronchoscopic navigation in peripheral pulmonary lesions].

Z B Chen1, Y P Jin, Y M Yu, D P Zhu, H Y Ma, L Chen, Y Zhang, Q L Ding, Z C Deng.   

Abstract

OBJECTIVE: To evaluate the diagnostic value of endobronchial ultrasound guide sheath transbronchial lung biopsy (EBUS-GS-TBLB) combined with virtual bronchoscopic navigation (VBN) in peripheral pulmonary lesions (PPLs).
METHODS: Cases with a PPL identified by computed tomography in Affiliated Hospital of Medical College of Ningbo University underwent EBUS-GS-TBLB with or without VBN randomly between Nov. 2014 to Aug. 2015. X-ray guidance was not performed in these cases. The sensitivity and the operation time were evaluated in the 2 groups.
RESULTS: A total of 184 patients were enrolled and completed this study. Among them 117 were males and 67 were females. There were 93 cases in the group of EBUS-GS-TBLB with VBN, and 91 in the group without VBN. The diagnostic sensitivity of VBN group was 72.04%(67/93). Among these positive cases, 64.1% cases (43/67) were malignant tumors, and 35.9% cases (24/67) were benign lesions. The mean operation time was (45±10)min. In the group without VBN, the diagnostic sensitivity was 69.23%(63/91), including 33 malignant tumors(52.4%, 33/63), and 30 benign lesions(47.6%, 30/63). The mean operation time was (55±10)min. There was no significant difference between EBUS-GS-TBLB with VBN group and EBUS-GS-TBLB without VBN group in diagnostic sensitivity (χ(2)=0.175, P=0.747). But there was a significant difference in the mean operation time between the 2 groups (t=6.522, P<0.001). EBUS-GS-TBLB was well tolerated. No severe procedure-related complications such as pneumothorax and hemoptysis were observed.
CONCLUSION: VBN cannot improve the diagnostic sensitivity, but it can clear the location of lesion, and shorten the operation time. This technique helps to abandon the X-ray guidance. EBUS-GS-TBLB combined with VBN is a safe and effective technique for PPLs.

Entities:  

Mesh:

Year:  2016        PMID: 27430920     DOI: 10.3760/cma.j.issn.1001-0939.2016.07.004

Source DB:  PubMed          Journal:  Zhonghua Jie He He Hu Xi Za Zhi        ISSN: 1001-0939


  2 in total

Review 1.  Endobronchial ultrasonography using a guide sheath technique for diagnosis of peripheral pulmonary lesions.

Authors:  Lei Zhang; Hongxu Wu; Guiqi Wang
Journal:  Endosc Ultrasound       Date:  2017 Sep-Oct       Impact factor: 5.628

2.  Virtual bronchoscopic navigation versus non-virtual bronchoscopic navigation assisted bronchoscopy for the diagnosis of peripheral pulmonary lesions: a systematic review and meta-analysis.

Authors:  Mohan Giri; Anju Puri; Ting Wang; Guichuan Huang; Shuliang Guo
Journal:  Ther Adv Respir Dis       Date:  2021 Jan-Dec       Impact factor: 4.031

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.