Literature DB >> 27428906

Evidence for Use of Frontozygomaticus and Contralateral Eurion as Hand-Caliper Landmarks for Assessment of Deformational Plagiocephaly.

Gary B Skolnick1, Sybill D Naidoo, Dennis C Nguyen, Kamlesh B Patel, Albert S Woo.   

Abstract

The severity of deformational plagiocephaly is frequently measured by cranial vault asymmetry (CVA). Cranial vault asymmetry is a simple linear proxy for the three-dimensional deformity. Different anthropometric landmarks have been suggested as the endpoints of the cross-cranial diagonals that determine CVA. One promising albeit counterintuitive set of digital landmarks is the frontozygomaticus and contralateral eurion. The validity of nondigital caliper measures associated with the diagonals defined by the frontozygomaticus and contralateral eurions has not been tested. In this study, the authors compare caliper measures against stereophotogrammetric measures that have been documented to correlate strongly with overall skull asymmetry.Cranial vault asymmetry was assessed by direct anthropometry with 2 different measures on 36 patients. Frontozygomaticus and contralateral eurion (fz-eu) and 30 degrees off the anteroposterior diameter (30offAP). Three-dimensional photographs were obtained and also used to quantify CVA in these subjects; digital measures of fz-eu and an overall measure of plagiocephaly (Global) were calculated. Global and 30offAP obtained at 31 patient visits in 2011 were also included.The measure best-correlated with overall Global asymmetry was digital fz-eu (R = 0.80). Caliper fz-eu was not strongly correlated with Global asymmetry (R = 0.27) or with digital fz-eu (R = 0.34). Differences between the digital and caliper fz-eu measures were 5 ± 4 mm (mean ± st. dev.). Differences between the caliper fz-eu and 30offAP measures were 6 ± 4 mm.Digital fz-eu shows an excellent correlation to Global asymmetry. However, attempts to replicate this result in the clinical setting by measuring fz-eu with calipers were unsuccessful.

Entities:  

Mesh:

Year:  2016        PMID: 27428906      PMCID: PMC5477979          DOI: 10.1097/SCS.0000000000002874

Source DB:  PubMed          Journal:  J Craniofac Surg        ISSN: 1049-2275            Impact factor:   1.046


  10 in total

1.  Comparison of infant head shape changes in deformational plagiocephaly following treatment with a cranial remolding orthosis using a noninvasive laser shape digitizer.

Authors:  Laura H Plank; Brian Giavedoni; Janet R Lombardo; Mark D Geil; Andrew Reisner
Journal:  J Craniofac Surg       Date:  2006-11       Impact factor: 1.046

2.  On the current incidence of deformational plagiocephaly: an estimation based on prospective registration at a single center.

Authors:  Timothy R Littlefield; Norman M Saba; Kevin M Kelly
Journal:  Semin Pediatr Neurol       Date:  2004-12       Impact factor: 1.636

3.  Quantifying positional plagiocephaly: reliability and validity of anthropometric measurements.

Authors:  Patricia A Mortenson; Paul Steinbok
Journal:  J Craniofac Surg       Date:  2006-05       Impact factor: 1.046

4.  Three-dimensional head shape quantification for infants with and without deformational plagiocephaly.

Authors:  I Atmosukarto; L G Shapiro; J R Starr; C L Heike; B Collett; M L Cunningham; M L Speltz
Journal:  Cleft Palate Craniofac J       Date:  2010-07

5.  Analysis of digital measures of cranial vault asymmetry for assessment of plagiocephaly.

Authors:  Gary B Skolnick; Sybill D Naidoo; Kamlesh B Patel; Albert S Woo
Journal:  J Craniofac Surg       Date:  2014-07       Impact factor: 1.046

6.  Outcome analysis after helmet therapy using 3D photogrammetry in patients with deformational plagiocephaly: the role of root mean square.

Authors:  Mahsa Bidgoli Moghaddam; Trevor M Brown; April Clausen; Trevor DaSilva; Emily Ho; Christopher R Forrest
Journal:  J Plast Reconstr Aesthet Surg       Date:  2013-12-17       Impact factor: 2.740

7.  An increase in infant cranial deformity with supine sleeping position.

Authors:  L C Argenta; L R David; J A Wilson; W O Bell
Journal:  J Craniofac Surg       Date:  1996-01       Impact factor: 1.046

8.  Comparison of Direct and Digital Measures of Cranial Vault Asymmetry for Assessment of Plagiocephaly.

Authors:  Gary B Skolnick; Sybill D Naidoo; Dennis C Nguyen; Kamlesh B Patel; Albert S Woo
Journal:  J Craniofac Surg       Date:  2015-09       Impact factor: 1.046

Review 9.  Head shape measurement standards and cranial orthoses in the treatment of infants with deformational plagiocephaly.

Authors:  Anthony McGarry; Melville T Dixon; Robert J Greig; David R L Hamilton; Sandra Sexton; Heather Smart
Journal:  Dev Med Child Neurol       Date:  2008-08       Impact factor: 5.449

10.  Negativity towards negative results: a discussion of the disconnect between scientific worth and scientific culture.

Authors:  Natalie Matosin; Elisabeth Frank; Martin Engel; Jeremy S Lum; Kelly A Newell
Journal:  Dis Model Mech       Date:  2014-02       Impact factor: 5.758

  10 in total