Literature DB >> 27425568

Comparative Evaluation of Flow Quantification across the Atrioventricular Valve in Patients with Functional Univentricular Heart after Fontan's Surgery and Healthy Controls: Measurement by 4D Flow Magnetic Resonance Imaging and Streamline Visualization.

Hoi Lam She1, Arno A W Roest2, Emmeline E Calkoen2, Pieter J van den Boogaard3, Rob J van der Geest3, Mark G Hazekamp4, Albert de Roos3, Jos J M Westenberg3.   

Abstract

PURPOSE: To evaluate the inflow pattern and flow quantification in patients with functional univentricular heart after Fontan's operation using 4D flow magnetic resonance imaging (MRI) with streamline visualization when compared with the conventional 2D flow approach.
METHOD: Seven patients with functional univentricular heart after Fontan's operation and twenty-three healthy controls underwent 4D flow MRI. In two orthogonal two-chamber planes, streamline visualization was applied, and inflow angles with peak inflow velocity (PIV) were measured. Transatrioventricular flow quantification was assessed using conventional 2D multiplanar reformation (MPR) and 4D MPR tracking the annulus and perpendicular to the streamline inflow at PIV, and they were validated with net forward aortic flow.
RESULTS: Inflow angles at PIV in the patient group demonstrated wide variation of angles and directions when compared with the control group (P < .01). The use of 4D flow MRI with streamlines visualization in quantification of the transatrioventricular flow had smaller limits of agreement (2.2 ± 4.1 mL; 95% limit of agreement -5.9-10.3 mL) when compared with the static plane assessment from 2DFlow MRI (-2.2 ± 18.5 mL; 95% limit of agreement agreement -38.5-34.1 mL). Stronger correlation was present in the 4D flow between the aortic and trans-atrioventricular flow (R2 correlation in 4D flow: 0.893; in 2D flow: 0.786).
CONCLUSIONS: Streamline visualization in 4D flow MRI confirmed variable atrioventricular inflow directions in patients with functional univentricular heart with previous Fontan's procedure. 4D flow aided generation of measurement planes according to the blood flood dynamics and has proven to be more accurate than the fixed plane 2D flow measurements when calculating flow quantifications.
© 2016 Wiley Periodicals, Inc.

Entities:  

Keywords:  4D Flow; Fontan; Magnetic Resonance Imaging

Mesh:

Year:  2016        PMID: 27425568     DOI: 10.1111/chd.12397

Source DB:  PubMed          Journal:  Congenit Heart Dis        ISSN: 1747-079X            Impact factor:   2.007


  6 in total

Review 1.  4D flow MRI applications in congenital heart disease.

Authors:  Judy Rizk
Journal:  Eur Radiol       Date:  2020-09-01       Impact factor: 5.315

Review 2.  Unravelling cardiovascular disease using four dimensional flow cardiovascular magnetic resonance.

Authors:  Vivian P Kamphuis; Jos J M Westenberg; Roel L F van der Palen; Nico A Blom; Albert de Roos; Rob van der Geest; Mohammed S M Elbaz; Arno A W Roest
Journal:  Int J Cardiovasc Imaging       Date:  2016-11-25       Impact factor: 2.357

3.  Decreased Diastolic Ventricular Kinetic Energy in Young Patients with Fontan Circulation Demonstrated by Four-Dimensional Cardiac Magnetic Resonance Imaging.

Authors:  Pia Sjöberg; Einar Heiberg; Pär Wingren; Jens Ramgren Johansson; Torsten Malm; Håkan Arheden; Petru Liuba; Marcus Carlsson
Journal:  Pediatr Cardiol       Date:  2017-02-10       Impact factor: 1.655

4.  In-scan and scan-rescan assessment of LV in- and outflow volumes by 4D flow MRI versus 2D planimetry.

Authors:  Vivian P Kamphuis; Roel L F van der Palen; Patrick J H de Koning; Mohammed S M Elbaz; Rob J van der Geest; Albert de Roos; Arno A W Roest; Jos J M Westenberg
Journal:  J Magn Reson Imaging       Date:  2017-06-22       Impact factor: 4.813

5.  Direct measurement of atrioventricular valve regurgitant jets using 4D flow cardiovascular magnetic resonance is accurate and reliable for children with congenital heart disease: a retrospective cohort study.

Authors:  Kimberley Jacobs; Joseph Rigdon; Frandics Chan; Joseph Y Cheng; Marcus T Alley; Shreyas Vasanawala; Shiraz A Maskatia
Journal:  J Cardiovasc Magn Reson       Date:  2020-05-14       Impact factor: 5.364

6.  Stress increases intracardiac 4D flow cardiovascular magnetic resonance -derived energetics and vorticity and relates to VO2max in Fontan patients.

Authors:  Vivian P Kamphuis; Mohammed S M Elbaz; Pieter J van den Boogaard; Lucia J M Kroft; Hildo J Lamb; Mark G Hazekamp; Monique R M Jongbloed; Nico A Blom; Willem A Helbing; Arno A W Roest; Jos J M Westenberg
Journal:  J Cardiovasc Magn Reson       Date:  2019-07-25       Impact factor: 5.364

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.