Literature DB >> 27423680

Dual-energy dynamic CT of lung adenocarcinoma: correlation of iodine uptake with tumor gene expression.

Masahiro Yanagawa1, Eiichi Morii2, Akinori Hata3, Maki Fujiwara3, Tomoko Gyobu3, Ken Ueda3, Osamu Honda3, Noriyuki Tomiyama3.   

Abstract

OBJECTIVES: To compare iodine content (IC) of solitary lung cancer using dynamic measurements of CT attenuation (Hounsfield Units, HU) and to correlate their quantitative CT data with expressions of vascular endothelial growth factor (VEGF), epidermal growth factor receptor (EGFR) and hypoxia-inducible factor-1α (HIF-1α) using immunostaining methods.
METHODS: This study included 18 patients with adenocarcinoma, who undergone dual energy dynamic multiphase CT to examine solitary lung nodules (6 part-solid and 12 solid nodules). Tumor size was 21.1 mm±8.1 (9-39mm) [Mean±SD (range)]. Contrast volume was determined by weight (2ml/kg). Contrast volume and injection rate were 110.5 ml±17.2 (80-144ml) and 1.84ml/s±0.30 (1.3-2.4ml/s), respectively. Enhancement values ([CT value at each delayed scan-CT value at unenhanced scan]) and net enhancement values ([peak CT value-CT value at unenhanced scan]) were calculated in HU from 65keV monochromatic image. IC at each delayed scan was measured in mg/cm(3) from the iodine-water material decomposition pair on the advantage workstation VolumeShare4. Immunostaining using VEGF, EGFR, and HIF-1α was performed by two pathologists, who evaluated the expression level of them subjectively. Statistical analyses were performed with rank correlation tests and regression analysis.
RESULTS: IC at 2- and 3-minute delayed scan (x) and immunostaining score of HIF-1α (y) showed a significantly positive correlation (r=0.64 and 0.52, p=0.004 and 0.03): regression equation, y=1.34+0.58x and y=1.51+0.55x, respectively.
CONCLUSIONS: Dual-energy dynamic multiphase CT can measure iodine content in lung adenocarcinoma. Iodine content at 2- and 3-minute delayed scan might correlate with the expression level of HIF-1α.
Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Keywords:  Dual-energy dynamic multiphase CT; Iodine content; hypoxia-inducible factor-1α; lung adenocarcinoma

Mesh:

Substances:

Year:  2016        PMID: 27423680     DOI: 10.1016/j.ejrad.2016.05.016

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  4 in total

Review 1.  Extra-abdominal dual-energy CT applications: a comprehensive overview.

Authors:  Giuseppe Cicero; Giorgio Ascenti; Moritz H Albrecht; Alfredo Blandino; Marco Cavallaro; Tommaso D'Angelo; Maria Ludovica Carerj; Thomas J Vogl; Silvio Mazziotti
Journal:  Radiol Med       Date:  2020-01-10       Impact factor: 3.469

2.  Impact of low iodine density tumor area ratio on the local control of non-small cell lung cancer through stereotactic body radiotherapy.

Authors:  Mitsuki Tanaka; Ichise Koji; Ichitaro Fujioka; Mariko Sato; Katsumi Hirose; Hideo Kawaguchi; Yoshiomi Hatayama; Yoshihiro Takai; Eiki Tsushima; Masahiko Aoki
Journal:  J Radiat Res       Date:  2021-05-12       Impact factor: 2.724

3.  Comparative study of dual energy CT iodine imaging and standardized concentrations before and after chemoradiotherapy for esophageal cancer.

Authors:  Xiaomin Ge; Jingping Yu; Zhongling Wang; Yiqun Xu; Changjie Pan; Lu Jiang; Yanling Yang; Kai Yuan; Wei Liu
Journal:  BMC Cancer       Date:  2018-11-16       Impact factor: 4.430

4.  Combined whole-lesion radiomic and iodine analysis for differentiation of pulmonary tumors.

Authors:  Lea Azour; Jane P Ko; Thomas O'Donnell; Nihal Patel; Priya Bhattacharji; William H Moore
Journal:  Sci Rep       Date:  2022-07-12       Impact factor: 4.996

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.