Literature DB >> 27421980

Simultaneous in-vial acetylation solid-phase microextraction followed by gas chromatography tandem mass spectrometry for the analysis of multiclass organic UV filters in water.

Marlene Vila1, Maria Celeiro1, J Pablo Lamas1, Carmen Garcia-Jares1, Thierry Dagnac2, Maria Llompart3.   

Abstract

UV filters are a class of emerging contaminants that are widely used in personal care products (PCPs) and that can be detected at low concentrations in the aquatic environment (ngL-1). Sensitive modern analytical methods are then mandatory to accurately analyze them. A methodology based on solid-phase-microextraction (SPME), considered as a 'Green Chemistry' technique, followed by gas chromatography-tandem mass spectrometry (GC-MS/MS) has been developed for the simultaneous analysis of 14 UV filters of different chemical nature in environmental and recreational waters. In-vial low-cost derivatization was carried out to improve chromatographic performance of phenolic compounds. The extraction parameters (fiber coating, extraction mode, and salt addition) were optimized by means of experimental designs in order to achieve reliable conditions. Finally, the SPME-GC-MS/MS method was validated in terms of linearity, accuracy and precision with LODs in the low ngL-1 level. Its application to the analysis of 28 different samples including sea, river, spa, swimming pool, and aquapark waters, enabled the detection of 11 target UV filters at concentration levels up to 540μgL-1, highlighting the presence of OCR in all analyzed samples and of 2EHMC (proposed to be considered as priority pollutant) in 79% of them. Copyright Â
© 2016 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Emerging contaminants; GC–MS/MS; Personal care products; SPME; Ultraviolet filters; Water analysis

Mesh:

Substances:

Year:  2016        PMID: 27421980     DOI: 10.1016/j.jhazmat.2016.06.056

Source DB:  PubMed          Journal:  J Hazard Mater        ISSN: 0304-3894            Impact factor:   10.588


  3 in total

1.  Target, Suspect and Non-Target Screening of Silylated Derivatives of Polar Compounds Based on Single Ion Monitoring GC-MS.

Authors:  Bhekumuzi Prince Gumbi; Brenda Moodley; Grace Birungi; Patrick Gathura Ndungu
Journal:  Int J Environ Res Public Health       Date:  2019-10-21       Impact factor: 3.390

2.  Determination of Benzophenones in Water and Cosmetics Samples: A Comparison of Solid-Phase Extraction and Microextraction by Packed Sorbent Methods.

Authors:  Grażyna Wejnerowska; Izabela Narloch
Journal:  Molecules       Date:  2021-11-16       Impact factor: 4.411

3.  A paper-based polystyrene/nylon Janus platform for the microextraction of UV filters in water samples as proof-of-concept.

Authors:  Juan L Benedé; Alberto Chisvert; Rafael Lucena; Soledad Cárdenas
Journal:  Mikrochim Acta       Date:  2021-10-25       Impact factor: 5.833

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.