Literature DB >> 27421681

Relationship between costovertebral joint kinematics and lung volume in supine humans.

Benoît Beyer1, Serge Van Sint Jan2, Laurence Chèze3, Victor Sholukha4, Véronique Feipel5.   

Abstract

This study investigates the relationship between the motion of the first ten costovertebral joints (CVJ) and lung volume over the inspiratory capacity (IC) using detailed kinematic analysis in a sample of 12 asymptomatic subjects. Retrospective codified spiral-CT data obtained at total lung capacity (TLC), middle of inspiratory capacity (MIC) and at functional residual capacity (FRC) were analysed. CVJ 3D kinematics were processed using previously-published methods. We tested the influence of the side, CVJ level and lung volume on CVJ kinematics. In addition, the correlations between anthropologic/pulmonary variables and CVJ kinematics were analysed. No linear correlation was found between lung volumes and CVJ kinematics. Major findings concerning 3D kinematics can be summarized as follows: 1) Ranges-of-motion decrease gradually with increasing CVJ level; 2) rib displacements are significantly reduced at lung volumes above the MIC and do not differ between CVJ levels; 3) the axes of rotation of the ribs are similarly oriented for all CVJ levels.
Copyright © 2016 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Year:  2016        PMID: 27421681     DOI: 10.1016/j.resp.2016.07.003

Source DB:  PubMed          Journal:  Respir Physiol Neurobiol        ISSN: 1569-9048            Impact factor:   1.931


  3 in total

1.  Rib cage anatomy in Homo erectus suggests a recent evolutionary origin of modern human body shape.

Authors:  Markus Bastir; Daniel García-Martínez; Nicole Torres-Tamayo; Carlos A Palancar; Benoît Beyer; Alon Barash; Chiara Villa; Juan Alberto Sanchis-Gimeno; Alberto Riesco-López; Shahed Nalla; Isabel Torres-Sánchez; Francisco García-Río; Ella Been; Asier Gómez-Olivencia; Martin Haeusler; Scott A Williams; Fred Spoor
Journal:  Nat Ecol Evol       Date:  2020-07-06       Impact factor: 15.460

2.  An Analysis of Respiration with the Smart Sensor SENSIRIB in Patients Undergoing Thoracic Surgery.

Authors:  Marco Ceccarelli; Riccardo Taje; Paula Elena Papuc; Vincenzo Ambrogi
Journal:  Sensors (Basel)       Date:  2022-02-17       Impact factor: 3.576

3.  Variation in human 3D trunk shape and its functional implications in hominin evolution.

Authors:  Markus Bastir; José María González Ruíz; Javier Rueda; Gonzalo Garrido López; Marta Gómez-Recio; Benoit Beyer; Alejandro F San Juan; Enrique Navarro
Journal:  Sci Rep       Date:  2022-07-11       Impact factor: 4.996

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.