| Literature DB >> 27419844 |
James P Buttress1, David P Day1, James M Courtney1, Elliot J Lawrence1, David L Hughes1, Robin J Blagg1, Alison Crossley2, Susan E Matthews3, Carl Redshaw4, Philip C Bulman Page1, Gregory G Wildgoose1.
Abstract
We herein report the synthesis of novel "Janus" calix[4]arenes bearing four "molecular tethering" functional groups on either the upper or lower rims of the calixarene. These enable facile multipoint covalent attachment to electrode surfaces with monolayer coverage. The other rim of the calixarenes bear either four azide or four ethynyl functional groups, which are easily modified by the copper(I)-catalyzed azide-alkyne cycloaddition reaction (CuAAC), either pre- or postsurface modification, enabling these conical, nanocavity reactor sites to be decorated with a wide range of substrates to impart desired chemical properties. Redox active species decorating the peripheral rim are shown to be electrically connected by the calixarene to the electrode surface in either "up" or "down" orientations of the calixarene.Entities:
Year: 2016 PMID: 27419844 PMCID: PMC4980688 DOI: 10.1021/acs.langmuir.6b02222
Source DB: PubMed Journal: Langmuir ISSN: 0743-7463 Impact factor: 3.882
Figure 1(A) Structure of Janus calix[4]arene (“N” groups are either azide or amine functionality). (B) Illustrates the cone structure of Janus calixarene. (C) The calixarene immobilized onto a surface by (i) the lower rim and (ii) the upper rim.
Figure 2Synthesis of cone-5,11,17,23-tetra-azido-25,26,27,28-propargylcalix[4]arene 8.
Figure 3(A) Calix[4]arene 13 immobilized onto GCE surface. (B) Overlaid cyclic voltammograms recorded in CH2Cl2/0.1 M [Bu4N][PF6] at scan rates of 50–750 mV s–1 for a GC electrode modified with calixarene 6 after further modification with ferrocenyl methyl azide moieties to form calix[4]arene 13 attached by the upper rim. (C) Corresponding plot of peak current versus scan rate.
Figure 4(A) Overlaid cyclic voltammograms of a GC electrode modified with 5 in 1 M HCl/1 M KCl, scan rate 0.1 V s–1. (B) Corresponding plot of peak current versus scan rate. (C) Overlaid cyclic voltammograms of the modified electrode recorded at 50–750 mV s–1 over the reversible arylhydroxylamine/arylnitroso redox couple.
Figure 5(A) Overlaid cyclic voltammograms of a GCE modified with 8 after postsurface modification in CH2Cl2/0.1 M NBu4PF6, scan rate 0.05–0.75 mV s–1. (B) Corresponding plot of peak current versus scan rate. (C) Structure of modified electrode surface.
Figure 6XPS spectra recorded over (a) the N1s region and (b) the F1s region of the modified GCE. (c) Structure of the functionalized calixarene attached to the GCE surface.