Abstract
BACKGROUND: Rupture of an anastomotic pseudoaneurysm after lower extremity prosthetic bypass is a rare problem, and the traditional mode of treatment has been open surgery. CASE DESCRIPTION: We report the endovascular management of a disrupted distal anastomosis of an above-knee femoro-popliteal Dacron bypass graft. Under local anesthesia and via a femoral cut-down, the Dacron graft was punctured and a 9 x 60 mm stent-graft was implanted resulting in successful pseudoaneurysm exclusion. The patient had an uneventful recovery.Entities:
Keywords: Dacron graft; anastomotic aneurysm; femoro-popliteal bypass; pseudoaneurysm; stent-graft
Year: 2015 PMID: 27418770 PMCID: PMC4938112