Literature DB >> 27418324

Rhythm Control and Its Relation to Symptoms during the First Two Years after Radiofrequency Ablation for Atrial Fibrillation.

Anna Björkenheim1, Axel Brandes2, Alexander Chemnitz2, Anders Magnuson3, Nils Edvardsson4, Dritan Poçi5.   

Abstract

CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov. Unique Identifier: NCT00697359.
OBJECTIVES: To evaluate rhythm control up to two years after atrial fibrillation (AF) ablation and its relation to reported symptoms.
BACKGROUND: The implantable loop recorder (ILR) continuously records the electrocardiogram (ECG), has an automatic AF detection algorithm, and has a possibility for patients to activate an ECG recording during symptoms.
METHODS: Fifty-seven patients (mean age 57 ± 9 years, 60% male, 88% paroxysmal AF) underwent AF ablation following ILR implantation. Device data were downloaded at the ablation and three, six, 12, 18, and 24 months after ablation.
RESULTS: Fifty-four patients completed the two-year follow-up. Thirteen (24%) patients had no AF episodes detected by ILR during follow-up. Ten of 41 patients (24%) with AF recurrence were only detected by ILR and AF recurrences were detected earlier by ILR (P < 0.001). The median AF burden in patients with AF recurrence was 5.7% (interquartile range 0.4-14.4) and was even lower in patients with AF only detected by ILR (P = 0.001). Forty-eight % of the patients indicated symptoms via the patient activator but 33% of those recordings were not due to AF. Early AF recurrence (within 3 months) was highly associated with later AF recurrence (P < 0.001). AF burden >0.5% and longest AF episode >6 hours before the ablation were independent predictors of AF recurrence during intermittent but not continuous monitoring.
CONCLUSIONS: After AF ablation, the AF burden was low throughout the 24 months follow-up. Nevertheless, symptoms were commonly indicated but one-third of patient-activated recordings did not show AF. Continuous monitoring was superior to intermittent follow-up in detecting AF episodes and assessing the AF burden.
© 2016 The Authors. Pacing and Clinical Electrophysiology published by Wiley Periodicals, Inc.

Entities:  

Keywords:  atrial fibrillation; catheter ablation; implantable loop recorder; monitoring; symptoms

Mesh:

Year:  2016        PMID: 27418324     DOI: 10.1111/pace.12916

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  2 in total

1.  Patient-Reported Outcomes in Relation to Continuously Monitored Rhythm Before and During 2 Years After Atrial Fibrillation Ablation Using a Disease-Specific and a Generic Instrument.

Authors:  Anna Björkenheim; Axel Brandes; Anders Magnuson; Alexander Chemnitz; Nils Edvardsson; Dritan Poçi
Journal:  J Am Heart Assoc       Date:  2018-02-24       Impact factor: 5.501

Review 2.  Size matters in atrial fibrillation: the underestimated importance of reduction of contiguous electrical mass underlying the effectiveness of catheter ablation.

Authors:  Adam Hartley; Joseph Shalhoub; Fu Siong Ng; Andrew D Krahn; Zachary Laksman; Jason G Andrade; Marc W Deyell; Prapa Kanagaratnam; Markus B Sikkel
Journal:  Europace       Date:  2021-11-08       Impact factor: 5.214

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.