Literature DB >> 27417733

Motion detection and amelioration in a dedicated cardiac solid-state CZT SPECT device.

John A Kennedy1, H William Strauss2.   

Abstract

A solid-state cadmium zinc tellurium (CZT) dedicated multipinhole cardiac camera which acquires all views simultaneously has been introduced for myocardial SPECT acquisition. We report a method to detect and ameliorate patient motion artifacts in myocardial perfusion imaging (MPI) studies recorded with this device. To detect motion, a myocardial phantom study was recorded, and at mid-scan, the phantom was moved stepwise along each of 6 orthogonal directions, causing MPI artifacts. Using QPS software (Cedars-Sinai) and an in-house normal database, displacements giving artifactual perfusion defects (total perfusion deficit score, TPD, >5 %) were all 1.5 cm or greater (11.2 ± 1.3 % for 1.5 cm). List mode data were reframed into 10-s steps, and the norm of the changes in center of mass among the 19 projections (32 × 32 matrix, pixel size 2.46 mm) was used as a motion index. Rejection of misregistered data gave artifact-free reconstructions (TPD = 1.0 ± 0.8 %) in phantom scans and reduced blur in a rest/stress clinical study. Blur on the patient's stress scan was consistent with increased motion compared to rest (motion index of 4.4 vs. 3.0 pixels, respectively). For CZT cameras that acquire data from multiple views simultaneously, motion during MPI can cause clinically significant artifacts. Reframing acquisitions into discrete time intervals enables the detection of motion and its amelioration, improving diagnostic accuracy.

Entities:  

Keywords:  Cadmium zinc telluride; Motion correction; Myocardial perfusion imaging; SPECT instrumentation; Ultrafast cardiac gamma camera

Mesh:

Substances:

Year:  2016        PMID: 27417733     DOI: 10.1007/s11517-016-1548-z

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  30 in total

1.  Automated quantification of myocardial perfusion SPECT using simplified normal limits.

Authors:  Piotr J Slomka; Hidetaka Nishina; Daniel S Berman; Cigdem Akincioglu; Aiden Abidov; John D Friedman; Sean W Hayes; Guido Germano
Journal:  J Nucl Cardiol       Date:  2005 Jan-Feb       Impact factor: 5.952

2.  Sources of attenuation-correction artefacts in cardiac PET/CT and SPECT/CT.

Authors:  Sarah J McQuaid; Brian F Hutton
Journal:  Eur J Nucl Med Mol Imaging       Date:  2008-01-25       Impact factor: 9.236

Review 3.  Advances in technical aspects of myocardial perfusion SPECT imaging.

Authors:  Piotr J Slomka; James A Patton; Daniel S Berman; Guido Germano
Journal:  J Nucl Cardiol       Date:  2009-02-26       Impact factor: 5.952

4.  Comparison of simultaneous dual-isotope multipinhole SPECT with rotational SPECT in a group of patients with coronary artery disease.

Authors:  Peter P Steele; Dennis L Kirch; John E Koss
Journal:  J Nucl Med       Date:  2008-06-13       Impact factor: 10.057

5.  Comparison of four motion correction techniques in SPECT imaging of the heart: a cardiac phantom study.

Authors:  M K O'Connor; K M Kanal; M W Gebhard; P J Rossman
Journal:  J Nucl Med       Date:  1998-12       Impact factor: 10.057

6.  Data-driven respiratory motion tracking and compensation in CZT cameras: a comprehensive analysis of phantom and human images.

Authors:  Chi-Lun Ko; Yen-Wen Wu; Mei-Fang Cheng; Ruoh-Fang Yen; Wen-Chau Wu; Kai-Yuan Tzen
Journal:  J Nucl Cardiol       Date:  2014-08-14       Impact factor: 5.952

7.  A fast cardiac gamma camera with dynamic SPECT capabilities: design, system validation and future potential.

Authors:  Moshe Bocher; Ira M Blevis; Leonid Tsukerman; Yigal Shrem; Gil Kovalski; Lana Volokh
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-06-29       Impact factor: 9.236

8.  Detection of respiratory tumour motion using intrinsic list mode-driven gating in positron emission tomography.

Authors:  Florian Büther; Iris Ernst; Mohammad Dawood; Peter Kraxner; Michael Schäfers; Otmar Schober; Klaus P Schäfers
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-07-06       Impact factor: 9.236

9.  Importance of correct patient positioning in myocardial perfusion SPECT when using a CZT camera.

Authors:  Cecilia Hindorf; Jenny Oddstig; Fredrik Hedeer; Magnus J Hansson; Jonas Jögi; Henrik Engblom
Journal:  J Nucl Cardiol       Date:  2014-05-08       Impact factor: 5.952

10.  Quantitative analysis of the tomographic thallium-201 myocardial bullseye display: critical role of correcting for patient motion.

Authors:  R Eisner; A Churchwell; T Noever; D Nowak; K Cloninger; D Dunn; W Carlson; J Oates; J Jones; D Morris
Journal:  J Nucl Med       Date:  1988-01       Impact factor: 10.057

View more
  1 in total

1.  Compared vulnerabilities to small cardiac motions between different cameras used for myocardial perfusion imaging.

Authors:  Julien Salvadori; Yolande Petegnief; Remi Sabbah; Olivier Morel; Hatem Boulahdour; Gilles Karcher; Pierre-Yves Marie; Laetitia Imbert
Journal:  J Nucl Cardiol       Date:  2018-01-11       Impact factor: 5.952

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.