Removal of Retrievable Self-Expandable Metallic Tracheobronchial Stents: An 18-Year Experience in a Single Center.

Jung-Hoon Park1, Pyeong Hwa Kim1, Ji Hoon Shin2, Jiaywei Tsauo1, Min Tae Kim1, Young Chul Cho1, Jin Hyoung Kim1, Ho-Young Song1.   

Abstract

PURPOSE: The purpose of the study was to retrospectively evaluate the technical outcomes of removal of retrievable self-expandable metallic stents (REMSs) and identify predictors of technical failure in 81 patients with benign and malignant tracheobronchial strictures.
MATERIALS AND METHODS: A total of 98 REMSs were removed under fluoroscopic guidance in 81 patients with benign (n = 48) or malignant (n = 33) tracheobronchial strictures. Primary and secondary technical success rates and complication rate were evaluated. Technical outcomes with regard to underlying diseases were also evaluated. Logistic regression models were constructed to identify predictors of primary technical success.
RESULTS: Primary and secondary technical success rates were 86.7 and 94.9 %, respectively. Stent removal-related complication rate was 7.1 % (7/98) and all were bleeding after stent removal. All bleeding complications were minor and managed conservatively. Primary technical success rate for benign strictures was significantly lower compared with that for malignant strictures (80.9 vs. 97.1 %, P = 0.029), but secondary technical success rate (93.7 vs. 97.1 %, P = 0.652) did not differ between the two groups. Granulation tissue formation was identified as an independent predictor of primary technical success (odds ratio 0.249, 95 % CI 0.071-0.874, P = 0.030).
CONCLUSION: Removal of REMSs in patients with benign and malignant tracheobronchial strictures is safe and technically feasible. Bronchoscopic guidance may be required when the removal using a hook wire fails. The presence of granulation tissue was the negative predictor of primary technical success.

Entities:  

Keywords:  Stent removal; Tracheobronchial stent; Tracheobronchial stricture

Mesh:

Year:  2016        PMID: 27417222     DOI: 10.1007/s00270-016-1420-4

Source DB:  PubMed          Journal:  Cardiovasc Intervent Radiol        ISSN: 0174-1551            Impact factor:   2.740


  4 in total

1.  Treatment of aerodigestive fistulas with a novel covered metallic Y-shaped segmented airway stent customized with the assistance of 3D printing.

Authors:  Qungang Shan; Wei Huang; Mingyi Shang; Ziyin Wang; Ning Xia; Qingsheng Xue; Aiwu Mao; Xiaoyi Ding; Zhongmin Wang
Journal:  Ann Transl Med       Date:  2021-07

2.  Metallic small y stent placement at primary right carina for bronchial disease.

Authors:  Yonghua Bi; Jindong Li; Zepeng Yu; Jianzhuang Ren; Gang Wu; Xinwei Han
Journal:  BMC Pulm Med       Date:  2018-11-29       Impact factor: 3.317

3.  Clinical outcomes of metallic Y-shaped covered stents for bronchopleural fistula around upper carina after lobectomy.

Authors:  Yonghua Bi; Xiaoyan Zhu; Zepeng Yu; Gang Wu; Xinwei Han; Jianzhuang Ren
Journal:  BMC Pulm Med       Date:  2019-11-05       Impact factor: 3.317

4.  Long-term outcomes of tracheal stents removal under fluoroscopy guidance: comparison of tracheal fistulas and tracheal stenosis.

Authors:  Yonghua Bi; Jindong Li; Liangliang Bai; Xinwei Han; Jianzhuang Ren
Journal:  BMC Pulm Med       Date:  2021-01-07       Impact factor: 3.317

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.