Literature DB >> 27413495

Is the Capsular Bag Perimeter Round or Elliptical?

Alfredo Amigó1, Sergio Bonaque-González2.   

Abstract

PURPOSE: To report findings that could suggest an elliptical shape of the capsular bag.
METHODS: Five eyes of three patients with axial length greater than 24 mm underwent phacoemulsification cataract surgery with plate-haptic multifocal toric intraocular lens (IOL) implantation oriented in the vertical meridian.
RESULTS: In all cases, correct orientation of the IOLs was verified 30 minutes after surgery. After 24 hours, all eyes demonstrated unwanted rotation of the IOLs ranging from 15 to 45 degrees. The IOLs remained stable in the new position in all cases until adhesion of the capsular bag took place.
CONCLUSION: These observations could suggest that the perimeter of the capsular bag has an elliptical shape. Therefore, the IOL tends to become fixated in a meridian of the capsular bag that best fits the diagonal diameter of the IOL.

Entities:  

Keywords:  Capsular Bag; Cataract Surgery; Intraocular Lens; Phacoemulsification Surgery

Year:  2016        PMID: 27413495      PMCID: PMC4926562          DOI: 10.4103/2008-322X.183925

Source DB:  PubMed          Journal:  J Ophthalmic Vis Res        ISSN: 2008-322X


  7 in total

1.  Rotational stability of a toric intraocular lens: influence of axial length and alignment in the capsular bag.

Authors:  Gauri D Shah; Mamidipudi R Praveen; Abhay R Vasavada; Viraj A Vasavada; Gauri Rampal; Lajja R Shastry
Journal:  J Cataract Refract Surg       Date:  2011-11-04       Impact factor: 3.351

2.  Direct measurement of the ciliary sulcus diameter by 35-megahertz ultrasound biomicroscopy.

Authors:  Jaeryung Oh; Hyung-Ho Shin; Jun-Heon Kim; Hyo-Myung Kim; Jong-Suk Song
Journal:  Ophthalmology       Date:  2007-09       Impact factor: 12.079

3.  [Surgical technique for centering diffractive intraocular lenses with open-loop haptics].

Authors:  A Amigó; S Bonaque
Journal:  Arch Soc Esp Oftalmol       Date:  2013-08-02

4.  Anterior segment changes during accommodation in eyes with a monofocal intraocular lens: high-frequency ultrasound study.

Authors:  Giorgio Marchini; Emilio Pedrotti; Marina Modesti; Silvia Visentin; Roberto Tosi
Journal:  J Cataract Refract Surg       Date:  2008-06       Impact factor: 3.351

5.  Rotational stability of a single-piece toric acrylic intraocular lens: a pilot study.

Authors:  Nino Hirnschall; Sophie Maedel; Maria Weber; Oliver Findl
Journal:  Am J Ophthalmol       Date:  2013-10-02       Impact factor: 5.258

6.  Prediction of pseudophakic capsular bag diameter based on biometric variables.

Authors:  C Vass; R Menapace; K Schmetterer; O Findl; G Rainer; I Steineck
Journal:  J Cataract Refract Surg       Date:  1999-10       Impact factor: 3.351

7.  Evaluation of the relationship between corneal diameter and lens diameter.

Authors:  Christopher Khng; Robert H Osher
Journal:  J Cataract Refract Surg       Date:  2008-03       Impact factor: 3.351

  7 in total
  1 in total

Review 1.  Comparison of the Clinical Performance of Refractive Rotationally Asymmetric Multifocal IOLs with Other Types of IOLs: A Meta-Analysis.

Authors:  Zequan Xu; Wenzhe Li; Lianqun Wu; Shuang Xue; Xu Chen; Qiang Wu
Journal:  J Ophthalmol       Date:  2018-09-27       Impact factor: 1.909

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.