Literature DB >> 27410358

Sensitive determinations of Cu, Pb, Cd, and Cr elements in aqueous solutions using chemical replacement combined with surface-enhanced laser-induced breakdown spectroscopy.

X Y Yang, Z Q Hao, C M Li, J M Li, R X Yi, M Shen, K H Li, L B Guo, X Y Li, Y F Lu, X Y Zeng.   

Abstract

In this study, chemical replacement combined with surface-enhanced laser-induced breakdown spectroscopy (CR-SENLIBS) was for the first time applied to improve the detection sensitivities of trace heavy metal elements in aqueous solutions. Utilizing chemical replacement effect, heavy metal ions in aqueous solution were enriched on the magnesium alloy surface as a solid replacement layer through reacting with the high chemical activity metallic magnesium (Mg) within 1 minute. Unitary and mixed solutions with Cu, Pb, Cd, and Cr elements were prepared to construct calibration curves, respectively. The CR-SENLIBS showed a much better detection sensitivity and accuracy for both unitary and mixed solutions. The coefficients of determination R<sup>2</sup> of the calibration curves were above 0.96, and the LoDs were of the same order of magnitude, i.e., in the range of 0.016-0.386 μg/mL for the unitary solution, and in the range of 0.025-0.420 μg/mL for the mixed solution. These results show that CR-SENLIBS is a feasible method for improving the detection sensitivity of trace element in liquid sample, which definitely provides a way for wider application of LIBS in water quality monitoring.

Entities:  

Year:  2016        PMID: 27410358     DOI: 10.1364/OE.24.013410

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  3 in total

1.  Identification of cervical cancer using laser-induced breakdown spectroscopy coupled with principal component analysis and support vector machine.

Authors:  Jing Wang; Liang Li; Ping Yang; Ying Chen; Yining Zhu; Ming Tong; Zhongqi Hao; Xiangyou Li
Journal:  Lasers Med Sci       Date:  2018-06-26       Impact factor: 3.161

2.  Laser Spectroscopic Sensors for the Development of Anthropomorphic Robot Sensitivity.

Authors:  Oleg Bukin; Dmitriy Proschenko; Alexey Chekhlenok; Sergey Golik; Ilya Bukin; Alexander Mayor; Victoriya Yurchik
Journal:  Sensors (Basel)       Date:  2018-05-23       Impact factor: 3.576

3.  Quantitative Analysis of Cadmium in Tobacco Roots Using Laser-Induced Breakdown Spectroscopy With Variable Index and Chemometrics.

Authors:  Fei Liu; Tingting Shen; Wenwen Kong; Jiyu Peng; Chi Zhang; Kunlin Song; Wei Wang; Chu Zhang; Yong He
Journal:  Front Plant Sci       Date:  2018-09-13       Impact factor: 5.753

  3 in total