Literature DB >> 27410154

High resolution corneal and single pulse imaging with line field spectral domain optical coherence tomography.

Samuel Lawman, Yue Dong, Bryan M Williams, Vito Romano, Stephen Kaye, Simon P Harding, Colin Willoughby, Yao-Chun Shen, Yalin Zheng.   

Abstract

We report the development of a Spectral Domain Line Field Optical Coherence Tomography (LF-OCT) system, using a broad bandwidth and spatial coherent Super-Continuum (SC) source. With conventional quasi-Continuous Wave (CW) setup we achieve axial resolutions up to 2.1 μm in air and 3D volume imaging speeds up to 213 kA-Scan/s. Furthermore, we report the use of a single SC pulse, of 2 ns duration, to temporally gate an OCT B-Scan image of 70 A-Scans. This is the equivalent of 35 GA-Scans/s. We apply the CW setup for high resolution imaging of the fine structures of a human cornea sample ex-vivo. The single pulse setup is applied to imaging of a coated pharmaceutical tablet. The fixed pattern noise due to spectral noise is removed by subtracting the median magnitude A-Scan. We also demonstrate that the Fourier phase can be used to remove aberration caused artefacts.

Entities:  

Year:  2016        PMID: 27410154     DOI: 10.1364/OE.24.012395

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  7 in total

1.  Buffer-averaging super-continuum source based spectral domain optical coherence tomography for high speed imaging.

Authors:  Chaoliang Chen; Weisong Shi; Robnier Reyes; Victor X D Yang
Journal:  Biomed Opt Express       Date:  2018-11-28       Impact factor: 3.732

2.  Dual-mode line-field confocal optical coherence tomography for ultrahigh-resolution vertical and horizontal section imaging of human skin in vivo.

Authors:  Jonas Ogien; Olivier Levecq; Hicham Azimani; Arnaud Dubois
Journal:  Biomed Opt Express       Date:  2020-02-10       Impact factor: 3.732

3.  Design of a Linear Wavenumber Spectrometer for Line Scanning Optical Coherence Tomography with 50 mm Focal Length Cylindrical Optics.

Authors:  Sevin Samadi; Masoud Mohazzab; Javad Dargahi; Sivakumar Narayanswamy
Journal:  Sensors (Basel)       Date:  2022-04-25       Impact factor: 3.847

4.  Deformation velocity imaging using optical coherence tomography and its applications to the cornea.

Authors:  Samuel Lawman; Peter W Madden; Vito Romano; Yue Dong; Sharon Mason; Bryan M Williams; Stephen B Kaye; Colin E Willoughby; Simon P Harding; Yao-Chun Shen; Yalin Zheng
Journal:  Biomed Opt Express       Date:  2017-11-13       Impact factor: 3.732

5.  Line-Field Optical Coherence Tomography as a tool for In vitro characterization of corneal biomechanics under physiological pressures.

Authors:  Ahmed Kazaili; Samuel Lawman; Brendan Geraghty; Ashkan Eliasy; Yalin Zheng; Yaochun Shen; Riaz Akhtar
Journal:  Sci Rep       Date:  2019-04-19       Impact factor: 4.379

6.  Accurate In Vivo Bowman's Thickness Measurement Using Mirau Ultrahigh Axial Resolution Line Field Optical Coherence Tomography.

Authors:  Samuel Lawman; Sharon Mason; Stephen B Kaye; Yao-Chun Shen; Yalin Zheng
Journal:  Transl Vis Sci Technol       Date:  2022-08-01       Impact factor: 3.048

Review 7.  Retinal and Corneal Changes Associated with Intraocular Silicone Oil Tamponade.

Authors:  Mariantonia Ferrara; Giulia Coco; Tania Sorrentino; Kirti M Jasani; George Moussa; Francesco Morescalchi; Felipe Dhawahir-Scala; Francesco Semeraro; David H W Steel; Vito Romano; Mario R Romano
Journal:  J Clin Med       Date:  2022-09-05       Impact factor: 4.964

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.