Literature DB >> 27409863

CW EC-QCL-based sensor for simultaneous detection of H<sub>2</sub>O, HDO, N<sub>2</sub>O and CH<sub>4</sub> using multi-pass absorption spectroscopy.

Yajun Yu, Nancy P Sanchez, Robert J Griffin, Frank K Tittel.   

Abstract

A sensor system based on a continuous wave, external-cavity quantum-cascade laser (CW EC-QCL) was demonstrated for simultaneous detection of atmospheric H<sub>2</sub>O, HDO, N<sub>2</sub>O and CH<sub>4</sub> using a compact, dense pattern multi-pass gas cell with an effective path-length of 57.6 m. The EC-QCL with a mode-hop-free spectral range of 1225-1285 cm<sup>-1</sup> operating at ~7.8 µm was scanned covering four neighboring absorption lines, for H<sub>2</sub>O at 1281.161 cm<sup>-1</sup>, HDO at 1281.455 cm<sup>-1</sup>, N<sub>2</sub>O at 1281.53 cm<sup>-1</sup> and CH<sub>4</sub> at 1281.61 cm<sup>-1</sup>. A first-harmonic-normalized wavelength modulation spectroscopy with second-harmonic detection (WMS-2f/1f) strategy was employed for data processing. An Allan-Werle deviation analysis indicated that minimum detection limits of 1.77 ppmv for H<sub>2</sub>O, 3.92 ppbv for HDO, 1.43 ppbv for N<sub>2</sub>O, and 2.2 ppbv for CH<sub>4</sub> were achieved with integration times of 50-s, 50-s, 100-s and 129-s, respectively. Experimental measurements of ambient air are also reported.

Entities:  

Year:  2016        PMID: 27409863     DOI: 10.1364/OE.24.010391

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  4 in total

1.  Repetitively Mode-Locked Cavity-Enhanced Absorption Spectroscopy (RML-CEAS) for Near-Infrared Gas Sensing.

Authors:  Qixin He; Minhan Lou; Chuantao Zheng; Weilin Ye; Yiding Wang; Frank K Tittel
Journal:  Sensors (Basel)       Date:  2017-12-02       Impact factor: 3.576

2.  Sensitive Spectroscopy of Acetone Using a Widely Tunable External-Cavity Quantum Cascade Laser.

Authors:  Faisal Nadeem; Julien Mandon; Amir Khodabakhsh; Simona M Cristescu; Frans J M Harren
Journal:  Sensors (Basel)       Date:  2018-06-27       Impact factor: 3.576

3.  Performance of a Mid-Infrared Sensor for Simultaneous Trace Detection of Atmospheric CO and N2O Based on PSO-KELM.

Authors:  Guolin Li; Zecheng Zhang; Xuena Zhang; Yunhui Wu; Kun Ma; Yue Jiao; Hao Zhao; Yimeng Song; Yajing Liu; Shenqiang Zhai
Journal:  Front Chem       Date:  2022-07-14       Impact factor: 5.545

4.  Beat frequency quartz-enhanced photoacoustic spectroscopy for fast and calibration-free continuous trace-gas monitoring.

Authors:  Hongpeng Wu; Lei Dong; Huadan Zheng; Yajun Yu; Weiguang Ma; Lei Zhang; Wangbao Yin; Liantuan Xiao; Suotang Jia; Frank K Tittel
Journal:  Nat Commun       Date:  2017-05-31       Impact factor: 14.919

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.