Abstract
Although budesonide is frequently used in veterinary medicine for the treatment of canine respiratory and bowel inflammatory diseases, knowledge is lacking regarding its kinetics in this species. We developed and validated a liquid chromatography-tandem mass spectrometry method for the determination of budesonide and its metabolite 16α-hydroxyprednisolone in dog plasma. The analytes were extracted by solid phase extraction and analysis was performed by high performance liquid chromatography-tandem mass spectrometry, with positive electrospray ionization.•This method allows budesonide and one of its main metabolites to be simultaneously quantified in dog plasma at fairly low concentrations.•The proposed protocol is very easy and fast to execute, without compromising analytical performances.•A small amount (0.5 mL) of plasma is required, making this approach suitable for pharmacokinetic studies also in small sized dogs.Entities:
Keywords: 16α-Hydroxyprednisolone; Budesonide; Dog; LC–MS/MS; Plasma
Year: 2016 PMID: 27408833 PMCID: PMC4929248 DOI: 10.1016/j.mex.2016.02.004
Source DB: PubMed Journal: MethodsX ISSN: 2215-0161
Fig. 1Chromatograms of a blank dog plasma sample fortified with budesonide (1.0 ng/mL), 16α-hydroxyprednisolone (1.0 ng/mL) and IS betamethasone (2.0 ng/mL).
Retention times and mass spectrometric details of budesonide, 16α-hydroxyprednisolone and betamethasone (internal standard).
| Analyte | Retention time (min) | Cone voltage (V) | Collision energy (eV) | Quantification transition ( | Confirmation transition ( |
|---|---|---|---|---|---|
| BUD | 8.35 | 15 | 11 | 431 > 413 | 431 > 323 |
| 16α-HP | 6.41 | 14 | 10 | 377 > 359 | 377 > 323 |
| BET | 7.42 | 16 | 8 | 393 > 373 | 393 > 147 |
Results of method validation.
| Analyte | Parameter | Fortification level | ||
|---|---|---|---|---|
| 0.5 ng/mL | 1 ng/mL | 5 ng/mL | ||
| Repeatability (CV%) | 8.1 | 9.1 | 13.0 | |
| BUD | Reproducibility (CV%) | 14.1 | 12.8 | 13.7 |
| Accuracy (bias%) | 2.4 | −2.6 | −3.0 | |
| Repeatability (CV%) | 9.4 | 1.6 | 9.2 | |
| 16α-HP | Reproducibility (CV%) | 18.9 | 12.3 | 11.3 |