Literature DB >> 27408108

How Robust are our Methods of Detecting Impaired Glomerular Filtration Rate in the Intensive Care Unit?

S K Joshi1, T Murari2, A S Narula3, K V Baliga4, V D Charan5.   

Abstract

BACKGROUND: Serum creatinine is not a sensitive marker to assess early loss of renal function in acute kidney injury. Timed creatinine clearance and several formula used to predict glomreular filtration rate have not been validated.
METHODS: In a prospective observational study in 50 adult patients admitted to the intensive care unit with apparent normal renal function, we assessed the glomerular filtration rate by the formula methods and timed creatinine clearance. RESULT: The mean serum creatinine was 0.77mg/dl, SD ± 0.15 (range 0.5-1.14 mg/dl). The mean measured creatinine clearance was 87.15 ml/min/1.73m(2), SD ± 20.5 (range 56.9-137 ml/min/1.73m(2)). In 25 (50%) patients, one hour urinary creatinine clearance was <80 ml/min/1.73m(2) and in two (4%) patients, the creatinine clearance was <60 ml/min/1.73m(2). Spearman correlation coefficient and regression analysis revealed a statistically significant correlation for the Cockcroft-Gault and predictive equations when compared with measured creatinine clearance. The differences between the predictive equations and creatinine clearance, as illustrated by the ±95% confidence interval in the Bland-Altman graphs was very significant [Cockcroft- Gault = -40.3 to 17.7 ml/min/ 1.73m(2), Modification of Diet in Renal Disease equation = -46.2 to 30.6 ml/min/1.73m(2) and the simplified Modification of Diet in Renal Disease equation = -72.8 to 24.8 ml/min/1.73m(2)].
CONCLUSION: Formula methods and creatinine clearance are more sensitive than serum creatinine in detecting early phase of acute kidney injury. However, there is no agreement between these methods of glomerular filtration rate estimation.

Entities:  

Keywords:  Acute kidney failure; Glomerular filtration rate

Year:  2011        PMID: 27408108      PMCID: PMC4921524          DOI: 10.1016/S0377-1237(08)80049-4

Source DB:  PubMed          Journal:  Med J Armed Forces India        ISSN: 0377-1237


  14 in total

1.  A clinical appraisal of the plasma concentration and endogenous clearance of creatinine.

Authors:  P D DOOLAN; E L ALPEN; G B THEIL
Journal:  Am J Med       Date:  1962-01       Impact factor: 4.965

Review 2.  Renal function testing.

Authors:  Mitchell H Rosner; W Kline Bolton
Journal:  Am J Kidney Dis       Date:  2006-01       Impact factor: 8.860

Review 3.  How to measure renal function in clinical practice.

Authors:  Jamie Traynor; Robert Mactier; Colin C Geddes; Jonathan G Fox
Journal:  BMJ       Date:  2006-10-07

4.  Prediction of creatinine clearance from serum creatinine.

Authors:  D W Cockcroft; M H Gault
Journal:  Nephron       Date:  1976       Impact factor: 2.847

5.  Acute kidney injury, mortality, length of stay, and costs in hospitalized patients.

Authors:  Glenn M Chertow; Elisabeth Burdick; Melissa Honour; Joseph V Bonventre; David W Bates
Journal:  J Am Soc Nephrol       Date:  2005-09-21       Impact factor: 10.121

Review 6.  Acute renal failure.

Authors:  Norbert Lameire; Wim Van Biesen; Raymond Vanholder
Journal:  Lancet       Date:  2005 Jan 29-Feb 4       Impact factor: 79.321

7.  Plasma clearance of iodine contrast media as a measure of glomerular filtration rate in critically ill patients.

Authors:  C M Erley; B D Bader; E D Berger; A Vochazer; J J Jorzik; K Dietz; T Risler
Journal:  Crit Care Med       Date:  2001-08       Impact factor: 7.598

8.  A more accurate method to estimate glomerular filtration rate from serum creatinine: a new prediction equation. Modification of Diet in Renal Disease Study Group.

Authors:  A S Levey; J P Bosch; J B Lewis; T Greene; N Rogers; D Roth
Journal:  Ann Intern Med       Date:  1999-03-16       Impact factor: 25.391

9.  A comparison of prediction equations for estimating glomerular filtration rate in adults without kidney disease.

Authors:  Julie Lin; Eric L Knight; Mary Lou Hogan; Ajay K Singh
Journal:  J Am Soc Nephrol       Date:  2003-10       Impact factor: 10.121

10.  Replacement of 24-h creatinine clearance by 2-h creatinine clearance in intensive care unit patients: a single-center study.

Authors:  Manuel E Herrera-Gutiérrez; Gemma Seller-Pérez; Esther Banderas-Bravo; Javier Muñoz-Bono; Miguel Lebrón-Gallardo; Juan F Fernandez-Ortega
Journal:  Intensive Care Med       Date:  2007-07-04       Impact factor: 17.440

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.