OBJECTIVES: The aim of this multicentre study is to report the clinical experiences of all patients undergoing transcatheter aortic valve implantation (TAVI) with a balloon-expandable device in Italy. METHODS: The Italian Transcatheter balloon-Expandable valve Registry (ITER) is a real-world registry that includes patients who have undergone TAVI with the Sapien (Edwards Lifesciences, Irvine, CA, USA) bioprosthesis in Italy since it became available in clinical practice. From 2007 to 2012, 1904 patients were enrolled to undergo TAVI in 33 Italian centres. Outcomes were classified according to the updated Valve Academic Research Consortium (VARC-2) definitions. A multivariable analysis was performed to identify independent predictors of all-cause mortality. RESULTS: Mean age was 81.7 (SD:6.2) years, and 1147 (60.2%) patients were female. Mean Logistic EuroSCORE was 21.1% (SD:13.7). Transfemoral, transapical, transaortic and transaxillary TAVI was performed in 1252 (65.8%), 630 (33.1%), 18 (0.9%) and 4 (0.2%) patients, respectively. Operative mortality was 7.2% (137 patients). The VARC-2 outcomes were as follows: device success, 88.1%; disabling stroke, 1.0%; life-threatening and major bleeding 9.8 and 10.5%, respectively; major vascular complication, 9.7%; acute kidney injury, 8.2%; acute myocardial infarction ≤72 h, 1.5%. Perioperative pacemaker implantation was necessary in 116 (6.1%) patients. At discharge, the mean transprosthetic gradient was 10.7 (SD:4.5) mmHg. Incidence of postoperative mild, moderate or severe paravalvular leak was, respectively, 32.1, 5.0 and 0.4%. A total of 444/1767 (25.1%) deaths after hospital discharge were reported: of these, 168 (37.8%) were classified as cardiac death. Preoperative independent predictors of all-cause mortality were male gender (HR: 1.395; 95% CI:1.052-1.849); overweight, BMI 25-30 kg/m2 (HR: 0.775; 95% CI: 0.616-0.974); serum creatinine level (every 1 mg/dl increase; HR: 1.314; 95% CI:1.167-1.480); haemoglobin level (every 1 g/dl increase; HR: 0.905; 95% CI:0.833-0.984); critical preoperative state (HR: 2.282; 95% CI: 1.384-3.761); neurological dysfunction (HR: 1.552; 95% CI:1.060-2.272); atrial fibrillation (HR: 1.556; 95% CI:1.213-1.995); pacemaker rhythm (HR: 1.948; 95% CI:1.310-2.896); NYHA Class III or IV (HR: 1.800; 95% CI:1.205-2.689 or HR: 2.331; 95% CI:1.392-3.903, respectively). CONCLUSIONS: TAVI with a balloon-expandable device in the 'real world' shows good mid-term outcomes in terms of survival, technical success, valve-related adverse events and haemodynamic performance.
OBJECTIVES: The aim of this multicentre study is to report the clinical experiences of all patients undergoing transcatheter aortic valve implantation (TAVI) with a balloon-expandable device in Italy. METHODS: The Italian Transcatheter balloon-Expandable valve Registry (ITER) is a real-world registry that includes patients who have undergone TAVI with the Sapien (Edwards Lifesciences, Irvine, CA, USA) bioprosthesis in Italy since it became available in clinical practice. From 2007 to 2012, 1904 patients were enrolled to undergo TAVI in 33 Italian centres. Outcomes were classified according to the updated Valve Academic Research Consortium (VARC-2) definitions. A multivariable analysis was performed to identify independent predictors of all-cause mortality. RESULTS: Mean age was 81.7 (SD:6.2) years, and 1147 (60.2%) patients were female. Mean Logistic EuroSCORE was 21.1% (SD:13.7). Transfemoral, transapical, transaortic and transaxillary TAVI was performed in 1252 (65.8%), 630 (33.1%), 18 (0.9%) and 4 (0.2%) patients, respectively. Operative mortality was 7.2% (137 patients). The VARC-2 outcomes were as follows: device success, 88.1%; disabling stroke, 1.0%; life-threatening and major bleeding 9.8 and 10.5%, respectively; major vascular complication, 9.7%; acute kidney injury, 8.2%; acute myocardial infarction ≤72 h, 1.5%. Perioperative pacemaker implantation was necessary in 116 (6.1%) patients. At discharge, the mean transprosthetic gradient was 10.7 (SD:4.5) mmHg. Incidence of postoperative mild, moderate or severe paravalvular leak was, respectively, 32.1, 5.0 and 0.4%. A total of 444/1767 (25.1%) deaths after hospital discharge were reported: of these, 168 (37.8%) were classified as cardiac death. Preoperative independent predictors of all-cause mortality were male gender (HR: 1.395; 95% CI:1.052-1.849); overweight, BMI 25-30 kg/m2 (HR: 0.775; 95% CI: 0.616-0.974); serum creatinine level (every 1 mg/dl increase; HR: 1.314; 95% CI:1.167-1.480); haemoglobin level (every 1 g/dl increase; HR: 0.905; 95% CI:0.833-0.984); critical preoperative state (HR: 2.282; 95% CI: 1.384-3.761); neurological dysfunction (HR: 1.552; 95% CI:1.060-2.272); atrial fibrillation (HR: 1.556; 95% CI:1.213-1.995); pacemaker rhythm (HR: 1.948; 95% CI:1.310-2.896); NYHA Class III or IV (HR: 1.800; 95% CI:1.205-2.689 or HR: 2.331; 95% CI:1.392-3.903, respectively). CONCLUSIONS: TAVI with a balloon-expandable device in the 'real world' shows good mid-term outcomes in terms of survival, technical success, valve-related adverse events and haemodynamic performance.
Authors: Adam Chakos; Ashley Wilson-Smith; Sameer Arora; Tom C Nguyen; Abhijeet Dhoble; Giuseppe Tarantini; Matthias Thielmann; John P Vavalle; Daniel Wendt; Tristan D Yan; David H Tian Journal: Ann Cardiothorac Surg Date: 2017-09
Authors: Giuseppe Tarantini; Paola A M Purita; Augusto D'Onofrio; Chiara Fraccaro; Anna Chiara Frigo; Gianpiero D'Amico; Luca Nai Fovino; Marta Martin; Francesco Cardaioli; Mostafa R A Badawy; Massimo Napodano; Gino Gerosa; Sabino Iliceto Journal: Ann Cardiothorac Surg Date: 2017-09
Authors: Martijn S van Mourik; Nathalie van der Velde; Giulio Mannarino; Marie-Pierre Thibodeau; Jean-Bernard Masson; Gennaro Santoro; Jan Baan; Sofie Jansen; Jana Kurucova; Martin Thoenes; Cornelia Deutsch; Andreas W Schoenenberger; Andrea Ungar; Peter Bramlage; M Marije Vis Journal: J Geriatr Cardiol Date: 2019-06 Impact factor: 3.327
Authors: M S van Mourik; J F Velu; V R Lanting; J Limpens; B J Bouma; J J Piek; J Baan; J P S Henriques; M M Vis Journal: Neth Heart J Date: 2020-05 Impact factor: 2.380
Authors: Marco B Ancona; Evelina Toscano; Francesco Moroni; Luca A Ferri; Filippo Russo; Barbara Bellini; Antonio Sorropago; Caterina Mula; Costanza Festorazzi; Marco Gamardella; Ciro Vella; Alessandro Beneduce; Vittorio Romano; Igor Belluschi; Nicola Buzzatti; Eustachio Agricola; Matteo Montorfano Journal: Int J Cardiol Heart Vasc Date: 2021-06-09