Literature DB >> 27403449

Enhanced resolution pulse-echo imaging with stabilized pulses.

Shujie Chen1, Kevin J Parker1.   

Abstract

Many pulse-echo imaging systems use focused beams to improve lateral resolution. The beam width is determined by the choice of source and apodization function, the frequency, and the physics of focusing. Postprocessing strategies to improve lateral resolution can be limited by the need for conditioning the mathematics of inverse filtering, due to instabilities. We present an analysis that defines key constraints on sampled versions of lateral beampatterns. Within these constraints are useful symmetric beampatterns, which, when properly sampled, can have a stable inverse filter. A framework for analysis and processing is described and applied to phantoms and tissues to demonstrate the improvements that can be realized.

Keywords:  Z-transform; deconvolution; lateral resolution enhancement; stable inverse filters; super-resolution; ultrasound images

Year:  2016        PMID: 27403449      PMCID: PMC4916161          DOI: 10.1117/1.JMI.3.2.027003

Source DB:  PubMed          Journal:  J Med Imaging (Bellingham)        ISSN: 2329-4302


  12 in total

1.  Two-dimensional noise-robust blind deconvolution of ultrasound images.

Authors:  T Taxt; J Strand
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2001-07       Impact factor: 2.725

2.  Transmission mode time-reversal super-resolution imaging.

Authors:  Sean K Lehman; Anthony J Devaney
Journal:  J Acoust Soc Am       Date:  2003-05       Impact factor: 1.840

3.  Superresolution imaging of scatterers in ultrasound B-scan imaging.

Authors:  Kevin J Parker
Journal:  J Acoust Soc Am       Date:  2012-06       Impact factor: 1.840

Review 4.  Synthetic aperture ultrasound imaging.

Authors:  Jørgen Arendt Jensen; Svetoslav Ivanov Nikolov; Kim Løkke Gammelmark; Morten Høgholm Pedersen
Journal:  Ultrasonics       Date:  2006-08-11       Impact factor: 2.890

5.  Wavelet restoration of medical pulse-echo ultrasound images in an EM framework.

Authors:  James Ng; Richard Prager; Nick Kingsbury; Graham Treece; Andrew Gee
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2007-03       Impact factor: 2.725

6.  Blind deconvolution of medical ultrasound images: a parametric inverse filtering approach.

Authors:  Oleg Michailovich; Allen Tannenbaum
Journal:  IEEE Trans Image Process       Date:  2007-12       Impact factor: 10.856

7.  Modeling ultrasound imaging as a linear, shift-variant system.

Authors:  James Ng; Richard Prager; Nick Kingsbury; Graham Treece; Andrew Gee
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2006-03       Impact factor: 2.725

8.  Apodization and windowing functions.

Authors:  Kevin J Parker
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2013-06       Impact factor: 2.725

9.  Apodization and windowing eigenfunctions.

Authors:  Kevin J Parker
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2014-09       Impact factor: 2.725

10.  A blind deconvolution approach to ultrasound imaging.

Authors:  Chengpu Yu; Cishen Zhang; Lihua Xie
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2012-02       Impact factor: 2.725

View more
  3 in total

1.  Errata: Enhanced resolution pulse-echo imaging with stabilized pulses.

Authors:  Shujie Chen; Kevin J Parker
Journal:  J Med Imaging (Bellingham)       Date:  2016-12-15

2.  Enhanced axial and lateral resolution using stabilized pulses.

Authors:  Shujie Chen; Kevin J Parker
Journal:  J Med Imaging (Bellingham)       Date:  2017-05-08

3.  Sub-wavelength lateral detection of tissue-approximating masses using an ultrasonic metamaterial lens.

Authors:  Ezekiel L Walker; Yuqi Jin; Delfino Reyes; Arup Neogi
Journal:  Nat Commun       Date:  2020-11-24       Impact factor: 14.919

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.