Literature DB >> 27402241

A Comprehensive Evaluation of a Novel Color Range Indicator in Multiple Blood Glucose Meters Demonstrates Improved Glucose Range Interpretation and Awareness in Subjects With Type 1 and Type 2 Diabetes.

Mike Grady1, Laurence B Katz2, Hilary Cameron3, Brian L Levy2.   

Abstract

AIMS: We previously demonstrated that people with type 2 diabetes (T2DM) can improve their ability to categorize blood glucose (BG) results into low, in range, or high glycemic ranges after experiencing a color range indicator (CRI or ColorSure™ Technology) in a single meter. This study examined whether a CRI was effective in people with type 1 (T1) or T2DM when used in 3 glucose meters.
METHODS: A total of 179 subjects (139 T2DM and 40 T1DM) classified BG values as low, in range, or high based on individual current knowledge. Subjects then experienced the CRI which showed whether different BG values were low, in range, or high. After CRI interaction, subjects repeated the classification.
RESULTS: Following interaction with the CRI, subjects significantly improved their ability to categorize BG results into low, in range, and high glycemic ranges by 27.9% (T2DM) and 27.2% (T1DM) (each P < .001). Improvement was not accompanied by an increase in time spent categorizing results. There was no difference in classification ability between subjects with T1 or T2DM. There was also no correlation between HbA1c, numeracy level, test frequency, or duration of diabetes and the ability to correctly classify results. Subjects agreed the CRI feature helped them easily interpret glucose values and improved their awareness of glucose ranges.
CONCLUSION: Interaction with a CRI improved the ability of subjects with T1 and T2DM to interpret and categorize BG values into recommended glycemic ranges, irrespective of the glucose meter providing the CRI insights.
© 2016 Diabetes Technology Society.

Entities:  

Keywords:  blood glucose monitor; color range indicator (ColorSure™ Technology); glucose ranges; numeracy; progress notes; self-monitoring of blood glucose

Mesh:

Substances:

Year:  2016        PMID: 27402241      PMCID: PMC5094336          DOI: 10.1177/1932296816659307

Source DB:  PubMed          Journal:  J Diabetes Sci Technol        ISSN: 1932-2968


  17 in total

Review 1.  5. Glycemic Targets.

Authors: 
Journal:  Diabetes Care       Date:  2016-01       Impact factor: 19.112

2.  Use of a blood glucose monitoring manual to enhance monitoring adherence in adults with diabetes: a randomized controlled trial.

Authors:  Elaine C Moreland; Lisa K Volkening; Margaret T Lawlor; Karen A Chalmers; Barbara J Anderson; Lori M B Laffel
Journal:  Arch Intern Med       Date:  2006-03-27

Review 3.  When does personalized feedback make a difference? A narrative review of recent findings and their implications for promoting better diabetes self-care.

Authors:  William H Polonsky; Lawrence Fisher
Journal:  Curr Diab Rep       Date:  2015-08       Impact factor: 4.810

Review 4.  Self-monitoring of blood glucose in type 2 diabetes: systematic review.

Authors:  C Clar; K Barnard; E Cummins; P Royle; N Waugh
Journal:  Health Technol Assess       Date:  2010-03       Impact factor: 4.014

5.  Poor numeracy skills are associated with glycaemic control in Type 1 diabetes.

Authors:  S Marden; P W Thomas; Z A Sheppard; J Knott; J Lueddeke; D Kerr
Journal:  Diabet Med       Date:  2012-05       Impact factor: 4.359

6.  Interactive Exposure With a Blood Glucose Monitor With a Novel Glucose Color Range Indicator Is Associated With Improved Glucose Range Interpretation and Awareness in Patients With Type 2 Diabetes.

Authors:  Mike Grady; Graham Warren; Brian L Levy; Laurence B Katz
Journal:  J Diabetes Sci Technol       Date:  2015-02-03

7.  Measuring numeracy without a math test: development of the Subjective Numeracy Scale.

Authors:  Angela Fagerlin; Brian J Zikmund-Fisher; Peter A Ubel; Aleksandra Jankovic; Holly A Derry; Dylan M Smith
Journal:  Med Decis Making       Date:  2007-07-19       Impact factor: 2.583

8.  Experiences of using blood glucose targets when following an intensive insulin regimen: a qualitative longitudinal investigation involving patients with Type 1 diabetes.

Authors:  D Rankin; D D Cooke; S Heller; J Elliott; S Amiel; J Lawton
Journal:  Diabet Med       Date:  2012-08       Impact factor: 4.359

9.  Evidence of a strong association between frequency of self-monitoring of blood glucose and hemoglobin A1c levels in T1D exchange clinic registry participants.

Authors:  Kellee M Miller; Roy W Beck; Richard M Bergenstal; Robin S Goland; Michael J Haller; Janet B McGill; Henry Rodriguez; Jill H Simmons; Irl B Hirsch
Journal:  Diabetes Care       Date:  2013-02-01       Impact factor: 19.112

10.  Patient-reported outcomes in type 2 diabetes mellitus: patients' and primary care physicians' perspectives in the Spanish health care system.

Authors:  Josep Franch-Nadal; Elena Labrador Barba; M Carmen Gómez-García; Pilar Buil-Cosiales; José Manuel Millaruelo; María Luisa Orera Peña
Journal:  Patient Prefer Adherence       Date:  2015-10-08       Impact factor: 2.711

View more
  9 in total

1.  Use of Blood Glucose Meters Featuring Color Range Indicators Improves Glycemic Control in Patients With Diabetes in Comparison to Blood Glucose Meters Without Color (ACCENTS Study).

Authors:  Mike Grady; Laurence B Katz; Brian L Levy
Journal:  J Diabetes Sci Technol       Date:  2018-05-31

2.  Analysis of "Use of Blood Glucose Meters Featuring Color Range Indicators Improves Glycemic Control and Patients With Diabetes in Comparison to Blood Glucose Meters Without Color (ACCENTS Study)".

Authors:  Andjela T Drincic
Journal:  J Diabetes Sci Technol       Date:  2018-08-10

3.  Use of Color Range Indicator Technology on Point-of-Care Meters May Ease Self-Management of Blood Glucose.

Authors:  Marc C Torjman
Journal:  J Diabetes Sci Technol       Date:  2016-11-01

4.  Pan-European Economic Analysis to Identify Cost Savings for the Health Care Systems as a Result of Integrating Glucose Monitoring Based Telemedical Approaches Into Diabetes Management.

Authors:  Katharina Fritzen; Kornelia Basinska; Matilde Rubio-Almanza; Antonio Nicolucci; Brian Kennon; Bruno Vergès; Katerina Zakrzewska; Oliver Schnell
Journal:  J Diabetes Sci Technol       Date:  2019-03-27

5.  Budget Impact of Improved Diabetes Management by Utilization of Glucose Meters With a Color-Range Indicator-Comparison of Five European Healthcare Systems.

Authors:  Katharina Fritzen; Kornelia Basinska; Constantin Stautner; Karl F Braun; Matilde Rubio-Almanza; Antonio Nicolucci; Brian Kennon; Bruno Vergès; Yasser Hosny; Oliver Schnell
Journal:  J Diabetes Sci Technol       Date:  2019-08-06

6.  A daily study of stressors, continuously measured glucose, and diabetes symptoms in latinos with type 2 diabetes.

Authors:  Julie Wagner; Stephen Armeli; Howard Tennen; Angela Bermudez-Millan; Howard Wolpert; Rafael Pérez-Escamilla
Journal:  J Behav Med       Date:  2020-06-03

7.  Patient Satisfaction and Clinical Efficacy of Novel Blood Glucose Meters Featuring Color Range Indicators in Patients With Type 2 Diabetes: A Prospective Study.

Authors:  Ayman Al Hayek; Asirvatham Alwin Robert; Mohamed Al Dawish
Journal:  Cureus       Date:  2020-10-27

8.  Evaluation of Patient Satisfaction and Clinical Efficacy of Using Blood Glucose Meters Featuring Color-Coded Indicators in Patients With Type 1 Diabetes: An Observational Hospital-Based Study.

Authors:  Ayman Al Hayek; Mohamed Al Dawish
Journal:  Cureus       Date:  2022-04-02

9.  Use of a Meter With Color-Range Indicators and a Mobile Diabetes Management App Improved Glycemic Control and Patient Satisfaction in an Underserved Hispanic Population: "Tu Salud"-A Randomized Controlled Partial Cross-Over Clinical Study.

Authors:  Laurence B Katz; Maria Aparicio; Hilary Cameron; Frederico Ceppa
Journal:  Diabetes Spectr       Date:  2022-02-08
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.