Literature DB >> 27400663

Dosimetric and radiobiological comparison of volumetric modulated arc therapy, high-dose rate brachytherapy, and low-dose rate permanent seeds implant for localized prostate cancer.

Ruijie Yang1, Nan Zhao2, Anyan Liao2, Hao Wang2, Ang Qu2.   

Abstract

To investigate the dosimetric and radiobiological differences among volumetric modulated arc therapy (VMAT), high-dose rate (HDR) brachytherapy, and low-dose rate (LDR) permanent seeds implant for localized prostate cancer. A total of 10 patients with localized prostate cancer were selected for this study. VMAT, HDR brachytherapy, and LDR permanent seeds implant plans were created for each patient. For VMAT, planning target volume (PTV) was defined as the clinical target volume plus a margin of 5mm. Rectum, bladder, urethra, and femoral heads were considered as organs at risk. A 78Gy in 39 fractions were prescribed for PTV. For HDR and LDR plans, the dose prescription was D90 of 34Gy in 8.5Gy per fraction, and 145Gy to clinical target volume, respectively. The dose and dose volume parameters were evaluated for target, organs at risk, and normal tissue. Physical dose was converted to dose based on 2-Gy fractions (equivalent dose in 2Gy per fraction, EQD2) for comparison of 3 techniques. HDR and LDR significantly reduced the dose to rectum and bladder compared with VMAT. The Dmean (EQD2) of rectum decreased 22.36Gy in HDR and 17.01Gy in LDR from 30.24Gy in VMAT, respectively. The Dmean (EQD2) of bladder decreased 6.91Gy in HDR and 2.53Gy in LDR from 13.46Gy in VMAT. For the femoral heads and normal tissue, the mean doses were also significantly reduced in both HDR and LDR compared with VMAT. For the urethra, the mean dose (EQD2) was 80.26, 70.23, and 104.91Gy in VMAT, HDR, and LDR brachytherapy, respectively. For localized prostate cancer, both HDR and LDR brachytherapy were clearly superior in the sparing of rectum, bladder, femoral heads, and normal tissue compared with VMAT. HDR provided the advantage in sparing of urethra compared with VMAT and LDR.
Copyright © 2016 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Biological effective dose; High-dose rate brachytherapy; Permanent seeds implant; Prostate cancer; Volumetric modulated arc therapy

Mesh:

Year:  2016        PMID: 27400663     DOI: 10.1016/j.meddos.2016.06.002

Source DB:  PubMed          Journal:  Med Dosim        ISSN: 1873-4022            Impact factor:   1.482


  5 in total

1.  Biological dose summation of intensity-modulated arc therapy and image-guided high-dose-rate interstitial brachytherapy in intermediate- and high-risk prostate cancer.

Authors:  Georgina Fröhlich; Péter Ágoston; Kliton Jorgo; Csaba Polgár; Tibor Major
Journal:  J Contemp Brachytherapy       Date:  2020-06-30

2.  Comparative dosimetrical analysis of intensity-modulated arc therapy, CyberKnife therapy and image-guided interstitial HDR and LDR brachytherapy of low risk prostate cancer.

Authors:  Georgina Fröhlich; Péter Ágoston; Kliton Jorgo; Gábor Stelczer; Csaba Polgár; Tibor Major
Journal:  Rep Pract Oncol Radiother       Date:  2021-04-14

3.  A comparison of outcomes for patients with intermediate and high risk prostate cancer treated with low dose rate and high dose rate brachytherapy in combination with external beam radiotherapy.

Authors:  Finbar Slevin; Sree Lakshmi Rodda; Peter Bownes; Louise Murray; David Bottomley; Clare Wilkinson; Ese Adiotomre; Bashar Al-Qaisieh; Emma Dugdale; Oliver Hulson; Joshua Mason; Jonathan Smith; Ann M Henry
Journal:  Clin Transl Radiat Oncol       Date:  2019-10-14

4.  High-Dose-Rate Brachytherapy Monotherapy versus Image-Guided Intensity-Modulated Radiotherapy with Helical Tomotherapy for Patients with Localized Prostate Cancer.

Authors:  Hideya Yamazaki; Koji Masui; Gen Suzuki; Satoaki Nakamura; Daisuke Shimizu; Tatsuyuki Nishikawa; Haruumi Okabe; Ken Yoshida; Tadayuki Kotsuma; Eiichi Tanaka; Keisuke Otani; Yasuo Yoshioka; Kazuhiko Ogawa
Journal:  Cancers (Basel)       Date:  2018-09-10       Impact factor: 6.639

Review 5.  The value of brachytherapy in the age of advanced external beam radiotherapy: a review of the literature in terms of dosimetry.

Authors:  Tibor Major; Georgina Fröhlich; Péter Ágoston; Csaba Polgár; Zoltán Takácsi-Nagy
Journal:  Strahlenther Onkol       Date:  2021-11-01       Impact factor: 3.621

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.