Literature DB >> 27400457

Information or resolution: Which is required from an SEM to study bulk inorganic materials?

Q Xing1.   

Abstract

Significant technological advances in scanning electron microscopy (SEM) have been achieved over the past years. Different SEMs can have significant differences in functionality and performance. This work presents the perspectives on selecting an SEM for research on bulk inorganic materials. Understanding materials demands quantitative composition and orientation information, and informative and interpretable images that reveal subtle differences in chemistry, orientation/structure, topography, and electronic structure. The capability to yield informative and interpretable images with high signal-to-noise ratios and spatial resolutions is an overall result of the SEM system as a whole, from the electron optical column to the detection system. The electron optical column determines probe performance. The roles of the detection system are to capture, filter or discriminate, and convert signal electrons to imaging information. The capability to control practical operating parameters including electron probe size and current, acceleration voltage or landing voltage, working distance, detector selection, and signal filtration is inherently determined by the SEM itself. As a platform for various accessories, e.g. an energy-dispersive spectrometer and an electron backscatter diffraction detector, the properties of the electron optical column, specimen chamber, and stage greatly affect the performance of accessories. Ease-of-use and ease-of-maintenance are of practical importance. It is practically important to select appropriate test specimens, design suitable imaging conditions, and analyze the specimen chamber geometry and dimensions to assess the overall functionality and performance of an SEM. For an SEM that is controlled/operated with a computer, the stable software and user-friendly interface significantly improve the usability of the SEM. SCANNING 38:864-879, 2016.
© 2016 Wiley Periodicals, Inc. © Wiley Periodicals, Inc.

Keywords:  detection performance; probe performance; scanning electron microscopy (SEM)

Year:  2016        PMID: 27400457     DOI: 10.1002/sca.21336

Source DB:  PubMed          Journal:  Scanning        ISSN: 0161-0457            Impact factor:   1.932


  1 in total

1.  A Novel Complex of Chitosan⁻Sodium Carbonate and Its Properties.

Authors:  Jianying Qian; Xiaomeng Wang; Jie Shu; Chang Su; Jinsong Gong; Zhenghong Xu; Jian Jin; Jinsong Shi
Journal:  Mar Drugs       Date:  2018-10-30       Impact factor: 5.118

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.