Literature DB >> 27400075

Visual Performance and Rotational Stability of a Multifocal Toric Intraocular Lens.

Eduardo F Marques, Tiago B Ferreira, Pedro Simões.   

Abstract

PURPOSE: To evaluate the visual results, refractive predictability, rotational stability, and spectacle independence of patients who had cataract surgery with implantation of a diffractive multifocal toric intraocular lens (IOL) (Tecnis Multifocal Toric ZMT 150-400; Abbott Medical Optics, Santa Ana, CA).
METHODS: This prospective study included 60 eyes of 30 patients with cataract and regular corneal astigmatism who had phacoemulsification with bilateral implantation of a Tecnis Multifocal Toric IOL. Over a 6-month follow-up period, the main outcome measures were uncorrected and corrected monocular and binocular distance (UDVA and DCVA), intermediate at 80 cm (UIVA and DCIVA), and near at 40 cm (UNVA and DCNVA) visual acuities, spherical equivalent (SE) refraction, residual astigmatism, rotational stability, defocus curves, contrast sensitivity, presence of photic phenomena, and use of spectacles.
RESULTS: Results at 6 months showed mean UDVA of 0.07 ± 0.1 logMAR (range: 0.3 to 0.0 logMAR), mean UIVA of 0.18 ± 0.09 logMAR (range: 0.3 to -0.1 log-MAR, and mean UNVA of 0.03 ± 0.09 logMAR (range: 0.2 to -0.1 logMAR). Refractive predictability was excellent with a mean SE of 0.05 ± 0.47 diopters (D) (range: -0.75 to +1.00 D) and a mean refractive cylinder of -0.44 ± 0.49 D (range: -1.25 to 0.00). Mean rotation was 3.18° ± 3.28°. Photic phenomena were moderate or severe in 30% of patients. All patients were spectacle independent at the 6-month follow-up visit at all distances in this case series.
CONCLUSIONS: The implantation of the Tecnis multifocal toric IOL in patients with cataract and corneal astigmatism provided excellent distance and near visual acuities with good intermediate visual acuity. Predictability of refractive results, rotational stability, and optical performance were excellent, allowing all patients in this series to achieve spectacle independence. [J Refract Surg. 2016;32(7):444-450.]. Copyright 2016, SLACK Incorporated.

Entities:  

Mesh:

Year:  2016        PMID: 27400075     DOI: 10.3928/1081597X-20160502-01

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  7 in total

1.  Combination of Toric and multifocal intraocular lens implantation in bilateral cataract patients with unilateral astigmatism.

Authors:  Jing-Li Liang; Fang Tian; Hong Zhang; He Teng
Journal:  Int J Ophthalmol       Date:  2016-12-18       Impact factor: 1.779

2.  Comparison of visual and refractive outcomes of diffractive bifocal toric and trifocal toric intraocular lenses 12 months after implantation in patients with moderate to high myopia.

Authors:  Abdulhakim Tekce; Mehmet Gulmez
Journal:  Int Ophthalmol       Date:  2021-04-16       Impact factor: 2.031

3.  Evaluating Rotational Stability of an Extended Depth of Focus Toric Intraocular Lens Using a Slit Lamp and Image-Based Analysis.

Authors:  Helga P Sandoval; Stephen Lane; Stephen Slade; Eric D Donnenfeld; Richard Potvin; Kerry D Solomon
Journal:  Clin Ophthalmol       Date:  2020-08-21

Review 4.  Premium intraocular lenses: The past, present and future.

Authors:  Jasmin Zvorničanin; Edita Zvorničanin
Journal:  J Curr Ophthalmol       Date:  2018-05-18

5.  Prospective comparative study of tolerance to refractive errors after implantation of extended depth of focus and monofocal intraocular lenses with identical aspheric platform in Korean population.

Authors:  Hyeck-Soo Son; Seong Ho Kim; Gerd U Auffarth; Chul Young Choi
Journal:  BMC Ophthalmol       Date:  2019-08-19       Impact factor: 2.209

Review 6.  Toric intraocular lenses: Expanding indications and preoperative and surgical considerations to improve outcomes.

Authors:  Vivek Mahendrapratap Singh; Muralidhar Ramappa; Somasheila I Murthy; Audrey Talley Rostov
Journal:  Indian J Ophthalmol       Date:  2022-01       Impact factor: 1.848

7.  Rotational stability and visual performance 3 months after bilateral implantation of a new toric extended range of vision intraocular lens.

Authors:  Kjell Gunnar Gundersen
Journal:  Clin Ophthalmol       Date:  2018-07-18
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.