Literature DB >> 27399645

Microfluidic blood-brain barrier model provides in vivo-like barrier properties for drug permeability screening.

Ying I Wang1, Hasan Erbil Abaci1, Michael L Shuler1.   

Abstract

Efficient delivery of therapeutics across the neuroprotective blood-brain barrier (BBB) remains a formidable challenge for central nervous system drug development. High-fidelity in vitro models of the BBB could facilitate effective early screening of drug candidates targeting the brain. In this study, we developed a microfluidic BBB model that is capable of mimicking in vivo BBB characteristics for a prolonged period and allows for reliable in vitro drug permeability studies under recirculating perfusion. We derived brain microvascular endothelial cells (BMECs) from human induced pluripotent stem cells (hiPSCs) and cocultured them with rat primary astrocytes on the two sides of a porous membrane on a pumpless microfluidic platform for up to 10 days. The microfluidic system was designed based on the blood residence time in human brain tissues, allowing for medium recirculation at physiologically relevant perfusion rates with no pumps or external tubing, meanwhile minimizing wall shear stress to test whether shear stress is required for in vivo-like barrier properties in a microfluidic BBB model. This BBB-on-a-chip model achieved significant barrier integrity as evident by continuous tight junction formation and in vivo-like values of trans-endothelial electrical resistance (TEER). The TEER levels peaked above 4000 Ω · cm2 on day 3 on chip and were sustained above 2000 Ω · cm2 up to 10 days, which are the highest sustained TEER values reported in a microfluidic model. We evaluated the capacity of our microfluidic BBB model to be used for drug permeability studies using large molecules (FITC-dextrans) and model drugs (caffeine, cimetidine, and doxorubicin). Our analyses demonstrated that the permeability coefficients measured using our model were comparable to in vivo values. Our BBB-on-a-chip model closely mimics physiological BBB barrier functions and will be a valuable tool for screening of drug candidates. The residence time-based design of a microfluidic platform will enable integration with other organ modules to simulate multi-organ interactions on drug response. Biotechnol. Bioeng. 2017;114: 184-194.
© 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

Entities:  

Keywords:  TEER; blood-brain barrier; human iPS cells; organ on a chip; permeability

Mesh:

Year:  2016        PMID: 27399645      PMCID: PMC6650146          DOI: 10.1002/bit.26045

Source DB:  PubMed          Journal:  Biotechnol Bioeng        ISSN: 0006-3592            Impact factor:   4.530


  156 in total

Review 1.  Ex Vivo Tumor-on-a-Chip Platforms to Study Intercellular Interactions within the Tumor Microenvironment.

Authors:  Vardhman Kumar; Shyni Varghese
Journal:  Adv Healthc Mater       Date:  2018-12-05       Impact factor: 9.933

2.  Monitoring of Microphysiological Systems: Integrating Sensors and Real-Time Data Analysis toward Autonomous Decision-Making.

Authors:  Ashlyn T Young; Kristina R Rivera; Patrick D Erb; Michael A Daniele
Journal:  ACS Sens       Date:  2019-04-19       Impact factor: 7.711

3.  Hydrophobic Patterning-Based 3D Microfluidic Cell Culture Assay.

Authors:  Sewoon Han; Junghyun Kim; Rui Li; Alice Ma; Vincent Kwan; Kevin Luong; Lydia L Sohn
Journal:  Adv Healthc Mater       Date:  2018-04-26       Impact factor: 9.933

Review 4.  Advances in ex vivo models and lab-on-a-chip devices for neural tissue engineering.

Authors:  Sahba Mobini; Young Hye Song; Michaela W McCrary; Christine E Schmidt
Journal:  Biomaterials       Date:  2018-05-11       Impact factor: 12.479

5.  Finite element modeling to analyze TEER values across silicon nanomembranes.

Authors:  Tejas S Khire; Barrett J Nehilla; Jirachai Getpreecharsawas; Maria E Gracheva; Richard E Waugh; James L McGrath
Journal:  Biomed Microdevices       Date:  2018-01-05       Impact factor: 2.838

6.  Perspective in Nuclear Theranostics Using Exosome for the Brain.

Authors:  Do Won Hwang
Journal:  Nucl Med Mol Imaging       Date:  2019-03-31

7.  3D self-organized microvascular model of the human blood-brain barrier with endothelial cells, pericytes and astrocytes.

Authors:  Marco Campisi; Yoojin Shin; Tatsuya Osaki; Cynthia Hajal; Valeria Chiono; Roger D Kamm
Journal:  Biomaterials       Date:  2018-07-12       Impact factor: 12.479

Review 8.  Assessing drug response in engineered brain microenvironments.

Authors:  Kinsley M Tate; Jennifer M Munson
Journal:  Brain Res Bull       Date:  2019-05-01       Impact factor: 4.077

Review 9.  Biomaterials and Culture Systems for Development of Organoid and Organ-on-a-Chip Models.

Authors:  Katya D'Costa; Milena Kosic; Angus Lam; Azeen Moradipour; Yimu Zhao; Milica Radisic
Journal:  Ann Biomed Eng       Date:  2020-04-13       Impact factor: 3.934

10.  Microphysiological Systems: Design, Fabrication, and Applications.

Authors:  Kai Wang; Kun Man; Jiafeng Liu; Yang Liu; Qi Chen; Yong Zhou; Yong Yang
Journal:  ACS Biomater Sci Eng       Date:  2020-05-10
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.