Literature DB >> 27398285

Erratum to: Dynamic contrast-enhanced breast MRI at 7T and 3T: an intra-individual comparison study.

Gisela L G Menezes1, Bertine L Stehouwer1, Dennis W J Klomp1, Tijl A van der Velden1, Maurice A A J van den Bosch1, Floortje M Knuttel1, Vincent O Boer1, Wybe J M van der Kemp1, Peter R Luijten1, Wouter B Veldhuis1.   

Abstract

[This corrects the article DOI: 10.1186/s40064-015-1654-7.].

Entities:  

Year:  2016        PMID: 27398285      PMCID: PMC4936985          DOI: 10.1186/s40064-016-2514-9

Source DB:  PubMed          Journal:  Springerplus        ISSN: 2193-1801


Erratum to: SpringerPlus (2016) 5:13 DOI 10.1186/s40064-015-1654-7

Figures 1, 2, and 3 did not display on the HTML version of the original article. This has now been updated in the original article (Menezes et al. 2016) and the figures included below (Figs. 1, 2, 3).
Fig. 1

7T (a–c) and 3T (d, e) MRI images of a 67-year-old female with an invasive lobular carcinoma in her right breast. Transverse image of 2nd post contrast-injection series (a, d) shows an irregular mass lesion with spiculated margins (arrows) on both field strengths. Inset shows zoomed-in image. Ultra-high resolution 7T image of the same slice (b). The kinetic curve assessment showed an initial rapid rise and wash-out pattern in the delayed phase on both field strengths (c, e). Both observers rated the lesion as BI-RADS 5

Fig. 2

7T (a, b, d) and 3T (c, e) MRI images of a 65-year-old female patient. The depicted lesion in her right breast was diagnosed as fibrocystic changes after biopsy. Sagittal images of 2nd post contrast-injection series (a, c) show a lobular lesion (arrow) with irregular (R1 at 3T) or smooth margins (R1 at 7T and R2 at 3T and 7T). Inset shows zoomed-in image. Ultra-high resolution 7T image of the same slice (b). The kinetic curve assessment at 7T shows a rapid rise and persistent pattern in the delayed phase (d), and at 3T a rapid rise and plateau pattern (e). R1 classified the lesion as BI-RADS 3, and R2 as BI-RADS 3 (3T) and BI-RADS 2 (7T)

Fig. 3

7T (a, b) and 3T (c, d) MRI results of a 47-year-old female patient with a history of inverted nipples. The biopsied index lesion in the right breast showed to be a cyst. Transverse image of 2nd post contrast-injection series (a, c). 7T MRI sagittal slice of high-resolution imaging (b), sagittal slice of 3T dynamic series at approximately the same location (d). At 7T MRI, diffuse non-mass-like enhancement was identified by R2, while R1 identified periductal enhancement (arrow). At 3T MRI, a focal non-mass-like enhancement was identified by R1 (circle), and multiple regions of non-mass-like enhancement were seen by R2. The observers rate the images BI-RADS 3 for 3T MRI, and BI-RADS 3 (R1) and 2 (R2) for 7T MRI

7T (a–c) and 3T (d, e) MRI images of a 67-year-old female with an invasive lobular carcinoma in her right breast. Transverse image of 2nd post contrast-injection series (a, d) shows an irregular mass lesion with spiculated margins (arrows) on both field strengths. Inset shows zoomed-in image. Ultra-high resolution 7T image of the same slice (b). The kinetic curve assessment showed an initial rapid rise and wash-out pattern in the delayed phase on both field strengths (c, e). Both observers rated the lesion as BI-RADS 5 7T (a, b, d) and 3T (c, e) MRI images of a 65-year-old female patient. The depicted lesion in her right breast was diagnosed as fibrocystic changes after biopsy. Sagittal images of 2nd post contrast-injection series (a, c) show a lobular lesion (arrow) with irregular (R1 at 3T) or smooth margins (R1 at 7T and R2 at 3T and 7T). Inset shows zoomed-in image. Ultra-high resolution 7T image of the same slice (b). The kinetic curve assessment at 7T shows a rapid rise and persistent pattern in the delayed phase (d), and at 3T a rapid rise and plateau pattern (e). R1 classified the lesion as BI-RADS 3, and R2 as BI-RADS 3 (3T) and BI-RADS 2 (7T) 7T (a, b) and 3T (c, d) MRI results of a 47-year-old female patient with a history of inverted nipples. The biopsied index lesion in the right breast showed to be a cyst. Transverse image of 2nd post contrast-injection series (a, c). 7T MRI sagittal slice of high-resolution imaging (b), sagittal slice of 3T dynamic series at approximately the same location (d). At 7T MRI, diffuse non-mass-like enhancement was identified by R2, while R1 identified periductal enhancement (arrow). At 3T MRI, a focal non-mass-like enhancement was identified by R1 (circle), and multiple regions of non-mass-like enhancement were seen by R2. The observers rate the images BI-RADS 3 for 3T MRI, and BI-RADS 3 (R1) and 2 (R2) for 7T MRI
  1 in total

1.  Dynamic contrast-enhanced breast MRI at 7T and 3T: an intra-individual comparison study.

Authors:  Gisela L G Menezes; Bertine L Stehouwer; Dennis W J Klomp; Tijl A van der Velden; Maurice A A J van den Bosch; Floortje M Knuttel; Vincent O Boer; Wybe J M van der Kemp; Peter R Luijten; Wouter B Veldhuis
Journal:  Springerplus       Date:  2016-01-05
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.