Literature DB >> 27397494

Corrosion-wear of β-Ti alloy TMZF (Ti-12Mo-6Zr-2Fe) in simulated body fluid.

Xueyuan Yang1, Christopher R Hutchinson2.   

Abstract

UNLABELLED: Titanium alloys are popular metallic implant materials for use in total hip replacements. Although, α+β titanium alloys such as Ti-6Al-4V have been the most commonly used alloys, the high Young's modulus (∼110GPa) leads to an undesirable stress shielding effect. An alternative is to use β titanium alloys that exhibit a significantly lower Young's modulus (∼70GPa). Femoral stems made of a β titanium alloy known as TMZF (Ti-12Mo-6Zr-2Fe (wt.%)) have been used as part of modular hip replacements since the early 2000's but these were recalled in 2011 by the US Food & Drug Administration (FDA) due to unacceptable levels of 'wear debris'. The wear was caused by small relative movement of the stem and neck at the junction where they fit together in the modular hip replacement design. In this study, the corrosion and wear properties of the TMZF alloy were investigated in simulated body fluid to identify the reason for the wear debris generation. Ti64 was used as a control for comparison. It is shown that the interaction between the surfaces of Ti64 and TMZF with simulated body fluid is very similar, both from the point of view of the products formed and the kinetics of the reaction. The dry wear behaviour of TMZF is also close to that of Ti64 and consistent with expectations based on Archard's law for abrasive wear. However, wear of Ti64 and TMZF in simulated body fluid show contrasting behaviours. A type of time-dependent wear test is used to examine the synergy between corrosion and wear of TMZF and Ti64. It is shown that the wear of TMZF accelerated rapidly in SBF whereas that of Ti64 is reduced. The critical role of the strain hardening capacity of the two materials and its role in helping the surface resist abrasion by hydroxyapatite particles formed as a result of the reaction with the SBF is discussed and recommendations are made for modifications that could be made to the TMZF alloy to improve the corrosion-wear response. STATEMENT OF SIGNIFICANCE: TMZF is a low modulus β-Ti alloy that has been used as the femoral stem in the Stryker modular design total hip replacement. It went into service in the early 2000's but was recalled by the FDA in 2011 due to unacceptable levels of wear debris released in the body which led to adverse physiological reactions. A large number of these implants remain in patients today. In this contribution, we investigate the corrosion (interaction of the alloy with simulated body fluid (SBF)), dry wear and then corrosion-wear in SBF to identify the origin of the unacceptable levels of wear that led to the FDA recall of this material. We use Ti-6Al-4V as a control and demonstrate that the reaction between Ti64 and TMZF with SBF is very similar in terms of both products formed and kinetics. We also show that the dry wear behaviour of TMZF is very similar to that of Ti64 and exactly as should be expected for the hardness of this material. However, the wear behaviours of TMZF and Ti64 are completed different in SBF and wear of TMZF is significantly accelerated in SBF. A type of time-dependent wear test is used to demonstrate the synergy between corrosion and wear and the key role of the strain hardening capacity (or lack thereof in the case of β-Ti) is discussed.
Copyright © 2016 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Corrosion-wear; Hip-implant; Simulated body fluid; TMZF; Ti64

Mesh:

Substances:

Year:  2016        PMID: 27397494     DOI: 10.1016/j.actbio.2016.07.008

Source DB:  PubMed          Journal:  Acta Biomater        ISSN: 1742-7061            Impact factor:   8.947


  6 in total

1.  Blood cobalt ion level in patients with different sizes of cobalt/chrome femoral head with the Accolade TMZF stem.

Authors:  Seiya Ishii; Yasuhiro Homma; Takehisa Matsukawa; Tomonori Baba; Kazuo Kaneko; Muneaki Ishijima
Journal:  Int Orthop       Date:  2022-07-15       Impact factor: 3.479

2.  Horror of three synergistic factors in THA: high mechanical stress, dissimilar metals, low elasticity stem: a case report.

Authors:  Seiya Ishii; Yasuhiro Homma; Takehisa Matsukawa; Tomonori Baba; Ayano Kubota; Kazuhito Yokoyama; Kazuo Kaneko; Muneaki Ishijima
Journal:  Arthroplasty       Date:  2021-10-05

3.  Investigation on tribological behaviors of biodegradable pure Zn and Zn-X (Li, Cu, Ge) binary alloys.

Authors:  Huafang Li; Jinyan Huang; Peng Zhang; Qi Zhang
Journal:  J Mater Sci Mater Med       Date:  2021-12-04       Impact factor: 3.896

4.  In-Depth Comparative Assessment of Different Metallic Biomaterials in Simulated Body Fluid.

Authors:  Radu Mirea; Andrei Tiberiu Cucuruz; Laurentiu Constantin Ceatra; Teodor Badea; Iuliana Biris; Elisa Popescu; Alexandru Paraschiv; Razvan Ene; Gabriela Sbarcea; Mihaiella Cretu
Journal:  Materials (Basel)       Date:  2021-05-24       Impact factor: 3.623

5.  Segregation mediated heterogeneous structure in a metastable β titanium alloy with a superior combination of strength and ductility.

Authors:  Junheng Gao; John Nutter; Xingguang Liu; Dikai Guan; Yuhe Huang; David Dye; W Mark Rainforth
Journal:  Sci Rep       Date:  2018-05-14       Impact factor: 4.379

6.  Effect of Ultrasonic Surface Impact on the Fatigue Properties of Ti3Zr2Sn3Mo25Nb.

Authors:  Zhangjianing Cheng; Xiaojian Cao; Xiaoli Xu; Qiangru Shen; Tianchong Yu; Jiang Jin
Journal:  Materials (Basel)       Date:  2020-05-02       Impact factor: 3.623

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.